Product comparison · 2 network switches

TP-Link JetStream 28-Port Gigabit SFP L2 Managed Network Switch vs TP-Link 16-Port 10/100Mbps + 2-Port Gigabit Unmanaged PoE Switch

Add a product
  • 38specifications compared
  • 18differ
  • 20identical
  • 58known for one product only

Key differences

  • Switch type
    • JetStream 28-Port Gigabit SFP L2 Managed Network Switch:Managed
    • 16-Port 10/100Mbps + 2-Port Gigabit Unmanaged PoE Switch:Unmanaged
  • Basic switching RJ-45 Ethernet ports quantity
    • JetStream 28-Port Gigabit SFP L2 Managed Network Switch:4
    • 16-Port 10/100Mbps + 2-Port Gigabit Unmanaged PoE Switch:20
  • MAC address table
    • JetStream 28-Port Gigabit SFP L2 Managed Network Switch:16000 entries
    • 16-Port 10/100Mbps + 2-Port Gigabit Unmanaged PoE Switch:8000 entries
  • Switching capacity
    • JetStream 28-Port Gigabit SFP L2 Managed Network Switch:128 Gbit/s
    • 16-Port 10/100Mbps + 2-Port Gigabit Unmanaged PoE Switch:7.2 Gbit/s
  • Forwarding rate
    • JetStream 28-Port Gigabit SFP L2 Managed Network Switch:95.2 Mpps
    • 16-Port 10/100Mbps + 2-Port Gigabit Unmanaged PoE Switch:5.36 Mpps
  • Jumbo frames
    • JetStream 28-Port Gigabit SFP L2 Managed Network Switch:9216
    • 16-Port 10/100Mbps + 2-Port Gigabit Unmanaged PoE Switch:10000
  • Packet buffer memory
    • JetStream 28-Port Gigabit SFP L2 Managed Network Switch:16 MB
    • 16-Port 10/100Mbps + 2-Port Gigabit Unmanaged PoE Switch:4.1 MB
  • Power consumption (max)
    • JetStream 28-Port Gigabit SFP L2 Managed Network Switch:29.67 W
    • 16-Port 10/100Mbps + 2-Port Gigabit Unmanaged PoE Switch:217.22 W

Side by side

Differences highlightedShow differences only (off)
Comparison of T2600G-28SQ, TL-SL1218MP
96 specifications
Management features1 differ
Switch typeDiffersManagedUnmanaged
Switch layerKnown for oneL2/L3Unknown — not stated by the source
Quality of Service (QoS) supportKnown for oneYesUnknown — not stated by the source
Web-based managementKnown for oneYesUnknown — not stated by the source
ARP inspectionKnown for oneYesUnknown — not stated by the source
System event logKnown for oneYesUnknown — not stated by the source
Ports & interfaces1 differ
Basic switching RJ-45 Ethernet ports quantityDiffers420
Basic switching RJ-45 Ethernet ports typeGigabit Ethernet (10/100/1000)Gigabit Ethernet (10/100/1000)
Installed SFP modules quantity00
Installed SFP+ modules quantity00
SFP module slots quantityKnown for one24Unknown — not stated by the source
SFP+ module slots quantityKnown for one4Unknown — not stated by the source
Fiber optic connectorKnown for oneSFP, SFP+Unknown — not stated by the source
Console portKnown for oneRJ-45Unknown — not stated by the source
Fast Ethernet (copper) ports quantityKnown for oneUnknown — not stated by the source16
Gigabit Ethernet (copper) ports quantityKnown for oneUnknown — not stated by the source2
Combo SFP ports quantityKnown for oneUnknown — not stated by the source2
Network2 differ
Networking standardsDiffersIEEE 802.1D, IEEE 802.1Q, IEEE 802.1p, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3az, IEEE 802.3i, IEEE 802.3u, IEEE 802.3x, IEEE 802.3zIEEE 802.3af, IEEE 802.3at
10G supportNoNo
Copper ethernet cabling technologyDiffers10BASE-T, 100BASE-TX10BASE-T, 100BASE-TX, 1000BASE-T
Port mirroringKnown for oneYesUnknown — not stated by the source
Broadcast storm controlKnown for oneYesUnknown — not stated by the source
Ethernet LAN data ratesKnown for one10,100,1000 Mbit/sUnknown — not stated by the source
Flow control supportKnown for oneYesUnknown — not stated by the source
Link aggregationKnown for oneYesUnknown — not stated by the source
Rate limitingKnown for oneYesUnknown — not stated by the source
Spanning tree protocolKnown for oneYesUnknown — not stated by the source
VLAN supportKnown for oneYesUnknown — not stated by the source
Virtual LAN featuresKnown for oneMAC address-based VLAN, Private VLAN, Protocol-based VLAN, VLAN Identifier ( VLAN ID), Voice VLANUnknown — not stated by the source
Number of VLANsKnown for one4000Unknown — not stated by the source
Auto MDI/MDI-XKnown for oneUnknown — not stated by the sourceYes
Auto-negotiationKnown for oneUnknown — not stated by the sourceYes
MAC address auto-aging supportedKnown for oneUnknown — not stated by the sourceYes
MAC address auto-learning supportedKnown for oneUnknown — not stated by the sourceYes
Optical fiberidentical
Fiber ethernet cabling technologyKnown for one10GBASE-X, 1000BASE-XUnknown — not stated by the source
Data transmission5 differ
MAC address tableDiffers16000 entries8000 entries
Switching capacityDiffers128 Gbit/s7.2 Gbit/s
Forwarding rateDiffers95.2 Mpps5.36 Mpps
Number of queuesKnown for one8Unknown — not stated by the source
Jumbo frames supportYesYes
Jumbo framesDiffers921610000
Path MTU discoveryKnown for oneYesUnknown — not stated by the source
Packet buffer memoryDiffers16 MB4.1 MB
Store-and-forwardKnown for oneUnknown — not stated by the sourceYes
Securityidentical
DHCP featuresKnown for oneDHCP client, DHCP relay, DHCP server, DHCP snooping, DHCPv6 client, DHCPv6 relay, DHCPv6 snoopingUnknown — not stated by the source
Access Control List (ACL)Known for oneYesUnknown — not stated by the source
IGMP snoopingKnown for oneYesUnknown — not stated by the source
BPDU filtering/protectionKnown for oneYesUnknown — not stated by the source
DoS attack preventionKnown for oneYesUnknown — not stated by the source
IP-MAC-Port bindingKnown for oneYesUnknown — not stated by the source
Loop protectionKnown for oneYesUnknown — not stated by the source
Password protectionKnown for oneYesUnknown — not stated by the source
Queue scheduling algorithmsKnown for oneWRR+SP, Weighted Round Robin (WRR)Unknown — not stated by the source
SSH/SSL supportKnown for oneYesUnknown — not stated by the source
Security algorithmsKnown for oneSNMP, SNMPv3, SSH, SSH-2, SSL/TLSUnknown — not stated by the source
Multicast featuresidentical
Multicast supportKnown for oneYesUnknown — not stated by the source
Protocolsidentical
GARP VLAN Registration Protocol (GVRP)Known for oneYesUnknown — not stated by the source
Designidentical
Rack mountingYesYes
Form factor1U1U
Product colourBlackBlack
Number of fans2 fan(s)2 fan(s)
StackableKnown for oneUnknown — not stated by the sourceNo
LED indicatorsKnown for oneUnknown — not stated by the sourceLAN, PoE, Status
Performanceidentical
Compatible operating systemsKnown for oneMicrosoft Windows 98SE, NT, 2000, XP, Vista, Windows 7/8, MAC OS, NetWare, UNIX, LinuxUnknown — not stated by the source
Firmware upgradeableKnown for oneYesUnknown — not stated by the source
sFlowKnown for oneYesUnknown — not stated by the source
Power1 differ
Power sourceACAC
Power supply includedYesYes
AC input voltage100 - 240 V100 - 240 V
AC input frequency50 - 60 Hz50 - 60 Hz
Power consumption (max)Differs29.67 W217.22 W
Power over Ethernet (PoE)1 differ
Power over Ethernet (PoE)DiffersNoYes
Power over Ethernet plus (PoE+) ports quantityKnown for oneUnknown — not stated by the source16
Power over Ethernet (PoE) power per portKnown for oneUnknown — not stated by the source30 W
Total Power over Ethernet (PoE) budgetKnown for oneUnknown — not stated by the source192 W
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-40 - 70 °C-40 - 70 °C
Operating relative humidity (H-H)10 - 90%10 - 90%
Storage relative humidity (H-H)5 - 90%5 - 90%
Heat dissipationDiffers101.23 BTU/h741.15 BTU/h
Weight & dimensions1 differ
Width440 mm440 mm
DepthDiffers220 mm180 mm
Height44 mm44 mm
Packaging content1 differ
Cables includedDiffersACLAN (RJ-45)
Rack mount kitKnown for oneYesUnknown — not stated by the source
User guideKnown for oneYesUnknown — not stated by the source
ManualKnown for oneUnknown — not stated by the sourceYes
Packaging data4 differ
Resource CDKnown for oneYesUnknown — not stated by the source
Rubber feetKnown for oneYesUnknown — not stated by the source
Package widthDiffers528 mm250 mm
Package depthDiffers336 mm528 mm
Package heightDiffers100 mm80 mm
Package weightDiffers4.2 kg2.96 kg
Package typeKnown for oneUnknown — not stated by the sourceBox
Certificatesidentical
CertificationCE, FCC, RoHSCE, FCC, RoHS
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85176990

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More network switch comparisons

All network switch comparisons