Product comparison · 2 network switches

D-Link DIS-200G-12PSW network switch Managed L2 Gigabit Ethernet (10/100/1000) Power over Ethernet (PoE) Black vs LevelOne 26-Port Gigabit PoE Switch, 2 x SFP, 24 PoE Outputs, 802.3at/af PoE

Add a product
  • 29specifications compared
  • 18differ
  • 11identical
  • 68known for one product only

Key differences

  • Switch type
    • DIS-200G-12PSW network switch Managed L2 Gigabit Ethernet (10/100/1000) Power over Ethernet (PoE) Black:Managed
    • 26-Port Gigabit PoE Switch, 2 x SFP, 24 PoE Outputs, 802.3at/af PoE:Unmanaged
  • Basic switching RJ-45 Ethernet ports quantity
    • DIS-200G-12PSW network switch Managed L2 Gigabit Ethernet (10/100/1000) Power over Ethernet (PoE) Black:10
    • 26-Port Gigabit PoE Switch, 2 x SFP, 24 PoE Outputs, 802.3at/af PoE:24
  • Installed SFP modules quantity
    • DIS-200G-12PSW network switch Managed L2 Gigabit Ethernet (10/100/1000) Power over Ethernet (PoE) Black:2
    • 26-Port Gigabit PoE Switch, 2 x SFP, 24 PoE Outputs, 802.3at/af PoE:0
  • Switching capacity
    • DIS-200G-12PSW network switch Managed L2 Gigabit Ethernet (10/100/1000) Power over Ethernet (PoE) Black:24 Gbit/s
    • 26-Port Gigabit PoE Switch, 2 x SFP, 24 PoE Outputs, 802.3at/af PoE:52 Gbit/s
  • Jumbo frames
    • DIS-200G-12PSW network switch Managed L2 Gigabit Ethernet (10/100/1000) Power over Ethernet (PoE) Black:9600
    • 26-Port Gigabit PoE Switch, 2 x SFP, 24 PoE Outputs, 802.3at/af PoE:10000
  • LED indicators
    • DIS-200G-12PSW network switch Managed L2 Gigabit Ethernet (10/100/1000) Power over Ethernet (PoE) Black:Yes
    • 26-Port Gigabit PoE Switch, 2 x SFP, 24 PoE Outputs, 802.3at/af PoE:LAN, PoE, Power, Uplink
  • Mean time between failures (MTBF)
    • DIS-200G-12PSW network switch Managed L2 Gigabit Ethernet (10/100/1000) Power over Ethernet (PoE) Black:156452 h
    • 26-Port Gigabit PoE Switch, 2 x SFP, 24 PoE Outputs, 802.3at/af PoE:43300 h
  • Power consumption (typical)
    • DIS-200G-12PSW network switch Managed L2 Gigabit Ethernet (10/100/1000) Power over Ethernet (PoE) Black:7.02 W
    • 26-Port Gigabit PoE Switch, 2 x SFP, 24 PoE Outputs, 802.3at/af PoE:500 W

Side by side

Differences highlightedShow differences only (on)
Comparison of DIS-200G-12PSW, GEP-2622W500
97 specifications
Management features1 differ
Switch typeDiffersManagedUnmanaged
Switch layerKnown for oneL2Unknown — not stated by the source
Quality of Service (QoS) supportKnown for oneYesUnknown — not stated by the source
Web-based managementKnown for oneYesUnknown — not stated by the source
Configuring Location Settings (CLI)Known for oneYesUnknown — not stated by the source
System event logKnown for oneYesUnknown — not stated by the source
Ports & interfaces2 differ
Basic switching RJ-45 Ethernet ports quantityDiffers1024
Gigabit Ethernet (copper) ports quantityKnown for one10Unknown — not stated by the source
Installed SFP modules quantityDiffers20
Console portKnown for oneRJ-45Unknown — not stated by the source
SFP module slots quantityKnown for oneUnknown — not stated by the source2
Network2 differ
Networking standardsDiffersIEEE 802.1D, IEEE 802.1Q, IEEE 802.1p, IEEE 802.1s, IEEE 802.1w, IEEE 802.1x, IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3af, IEEE 802.3at, IEEE 802.3az, IEEE 802.3u, IEEE 802.3x, IEEE 802.3zIEEE 802.3, IEEE 802.3ab, IEEE 802.3af, IEEE 802.3at, IEEE 802.3az, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z
Copper ethernet cabling technologyDiffers10BASE-T, 100BASE-TX, 1000BASE-T10BASE-T, 100BASE-TX, 1000BASE-TX
Port mirroringKnown for oneYesUnknown — not stated by the source
Active link detectionKnown for oneYesUnknown — not stated by the source
Broadcast storm controlKnown for oneYesUnknown — not stated by the source
Link aggregationKnown for oneYesUnknown — not stated by the source
Spanning tree protocolKnown for oneYesUnknown — not stated by the source
VLAN supportKnown for oneYesUnknown — not stated by the source
Virtual LAN featuresKnown for onePort-based VLAN, Tagged VLAN, Voice VLANUnknown — not stated by the source
Cable types supportedKnown for oneUnknown — not stated by the sourceCat3, Cat4, Cat5, Cat5e, Cat6, Cat7
Auto-negotiationKnown for oneUnknown — not stated by the sourceYes
MAC address auto-aging supportedKnown for oneUnknown — not stated by the sourceYes
MAC address auto-learning supportedKnown for oneUnknown — not stated by the sourceYes
Optical fiberidentical
Fiber ethernet cabling technologyKnown for one1000BASE-XUnknown — not stated by the source
Data transmission2 differ
Switching capacityDiffers24 Gbit/s52 Gbit/s
Forwarding rateKnown for one17.856 MppsUnknown — not stated by the source
Store-and-forwardKnown for oneYesUnknown — not stated by the source
Jumbo framesDiffers960010000
Packet forwarding rate (1 Gbps)Known for oneUnknown — not stated by the source1488000 pps
Packet forwarding rate (10 Mbps)Known for oneUnknown — not stated by the source14880 pps
Packet forwarding rate (100 Mbps)Known for oneUnknown — not stated by the source148800 pps
Packet buffer memoryKnown for oneUnknown — not stated by the source4.1 MB
Securityidentical
DHCP featuresKnown for oneDHCP clientUnknown — not stated by the source
IGMP snoopingKnown for oneYesUnknown — not stated by the source
AuthenticationKnown for onePort-based authenticationUnknown — not stated by the source
Authentication typeKnown for oneRADIUSUnknown — not stated by the source
Queue scheduling algorithmsKnown for oneSPQ, Weighted Round Robin (WRR)Unknown — not stated by the source
Security algorithmsKnown for one802.1x RADIUS, SSL/TLSUnknown — not stated by the source
Multicast featuresidentical
Multicast supportKnown for oneYesUnknown — not stated by the source
Protocolsidentical
Management protocolsKnown for oneSNMP v1/v2c/v3, SNTP, TelnetUnknown — not stated by the source
Design1 differ
StackableKnown for oneNoUnknown — not stated by the source
Housing materialKnown for oneMetalUnknown — not stated by the source
LED indicatorsDiffersYesLAN, PoE, Power, Uplink
DIN rail mountingKnown for oneYesUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP30Unknown — not stated by the source
Wall mountableKnown for oneYesUnknown — not stated by the source
SafetyKnown for oneUnknown — not stated by the sourceFCC Class A, CE
Regulatory ApprovalsKnown for oneUnknown — not stated by the sourceEMI: EN55032:2012+AC:2013, EN55022:2010+AC:2011, AS/NZS CISPR 22 Amdt. (2010), EN61000-3-2:2014, EN61000-3-3:2013, EMS: EN55024:2010, IEC61000-4-2:2008, IEC61000-4-3:2006+A1:2007+A2:2010, IEC61000-4 4:2012, IEC61000-4-5:2005, IEC61000-4-6:2013, IEC61000-4-8:2009, IEC61000-4-11:2004
Performance1 differ
Mean time between failures (MTBF)Differs156452 h43300 h
Power1 differ
Power sourceKnown for onePoEUnknown — not stated by the source
DC input voltageKnown for one46 - 54 VUnknown — not stated by the source
Power consumption (typical)Differs7.02 W500 W
AC input voltageKnown for oneUnknown — not stated by the source100 - 240 V
AC input frequencyKnown for oneUnknown — not stated by the source50 - 60 Hz
Output voltageKnown for oneUnknown — not stated by the source56 V
Output powerKnown for oneUnknown — not stated by the source30 W
Power over Ethernet (PoE)1 differ
Power over Ethernet (PoE) ports quantityDiffers824
Power over Ethernet (PoE) voltageKnown for one260 VUnknown — not stated by the source
Total Power over Ethernet (PoE) budgetKnown for one240 WUnknown — not stated by the source
Operational conditions3 differ
Operating temperature (T-T)Differs-40 - 75 °C-5 - 55 °C
Storage temperature (T-T)Differs-40 - 85 °C-20 - 70 °C
Operating relative humidity (H-H)Differs0 - 95%10 - 90%
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 2000 mUnknown — not stated by the source
Heat dissipationKnown for one887.16 BTU/hUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers171.2 mm200 mm
DepthDiffers53 mm44 mm
HeightDiffers210 mm440 mm
WeightDiffers1.76 kg3.4 kg
Certificatesidentical
CertificationKnown for oneCE, FCC, BSMI EN 61000-4-2 ESD EN 61000-4-3 RS EN 61000-4-4 EFT EN 61000-4-5 EN 61000-4-6 CS EN 61000-4-8 IEC 60068-2-27 IEC 60068-2-32 IEC 60068-2-6Unknown — not stated by the source
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Packaging dataidentical
Package typeKnown for oneUnknown — not stated by the sourceBox
Rubber feetKnown for oneUnknown — not stated by the sourceYes
Package widthKnown for oneUnknown — not stated by the source260 mm
Package depthKnown for oneUnknown — not stated by the source95 mm
Package heightKnown for oneUnknown — not stated by the source540 mm
Package weightKnown for oneUnknown — not stated by the source4 kg
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceTaiwan
Master (outer) case widthKnown for oneUnknown — not stated by the source510 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source280 mm
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85176990
Master (outer) case heightKnown for oneUnknown — not stated by the source555 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source18 kg
Products per master (outer) caseKnown for oneUnknown — not stated by the source5 pc(s)

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More network switch comparisons

All network switch comparisons