Product comparison · 2 network management devices

D-Link Nuclias Connect Hub Plus vs Vertiv Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord

Add a product
  • 13specifications compared
  • 9differ
  • 4identical
  • 17known for one product only

Key differences

The Vertiv Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord has 1 more Ethernet LAN (RJ-45) ports than the D-Link Nuclias Connect Hub Plus (2 vs 1). The Vertiv Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord has 3 more USB 2.0 ports quantity than the D-Link Nuclias Connect Hub Plus (4 vs 1). The D-Link Nuclias Connect Hub Plus has 5 - 95% more storage relative humidity (H-H) than the Vertiv Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord (10 - 95% vs 5 - 95%). AC input voltage: 12 V on the D-Link Nuclias Connect Hub Plus, 100 - 240 V on the Vertiv Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord. Operating relative humidity (H-H): 10 - 90% on the D-Link Nuclias Connect Hub Plus, 20 - 80% on the Vertiv Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord.

  • Ethernet LAN (RJ-45) ports
    • Nuclias Connect Hub Plus:1
    • Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord:2
  • USB 2.0 ports quantity
    • Nuclias Connect Hub Plus:1
    • Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord:4
  • AC input voltage
    • Nuclias Connect Hub Plus:12 V
    • Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord:100 - 240 V
  • Operating relative humidity (H-H)
    • Nuclias Connect Hub Plus:10 - 90%
    • Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord:20 - 80%
  • Operating temperature (T-T)
    • Nuclias Connect Hub Plus:0 - 40 °C
    • Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord:0 - 70 °C
  • Storage relative humidity (H-H)
    • Nuclias Connect Hub Plus:10 - 95%
    • Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord:5 - 95%
  • Storage temperature (T-T)
    • Nuclias Connect Hub Plus:-20 - 70 °C
    • Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord:-20 - 90 °C
  • Weight
    • Nuclias Connect Hub Plus:865 g
    • Avocent 2-Port ACS800 Serial Console with external AC/DC Power Brick - Global Datacenter PDU Power Cord:1.09 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of DNH-200, ACS802EAC-400
30 specifications
Performanceidentical
Number of LAN Access Points (max)Known for one50Unknown — not stated by the source
Networkidentical
Ethernet LANYesYes
Ethernet LAN data rates10,100,1000 Mbit/s10,100,1000 Mbit/s
Cabling technologyKnown for one10/100/1000BaseT(X)Unknown — not stated by the source
Wi-FiKnown for oneUnknown — not stated by the sourceNo
Management featuresidentical
Web-based managementKnown for oneYesUnknown — not stated by the source
Securityidentical
Security algorithmsKnown for oneHTTPS, SSHUnknown — not stated by the source
Ports & interfaces2 differ
Connectivity technologyWiredWired
Ethernet LAN (RJ-45) portsDiffers12
Console portRJ-45RJ-45
USB 2.0 ports quantityDiffers14
Serial ports quantityKnown for oneUnknown — not stated by the source2
Power1 differ
AC input voltageDiffers12 V100 - 240 V
Input currentKnown for one3 AUnknown — not stated by the source
Power consumption (typical)Known for one19 WUnknown — not stated by the source
AC input frequencyKnown for oneUnknown — not stated by the source50 - 60 Hz
Design1 differ
Rack mountingKnown for oneYesUnknown — not stated by the source
Rack capacityKnown for one1UUnknown — not stated by the source
LED indicatorsKnown for oneData, HDD, PowerUnknown — not stated by the source
CertificationDiffersFCC Class A, CE Class A, RCM, RoHS, WEEEFCC Class A CE Class A (EU) ICES-003 (Canada) VCCI (Japan) RCM (Australia) Customs Union (CU) KCC (Korea) UL (USA) cUL (Canada) EN-60950 (EU) CB Customs Union (CU)
Product colourKnown for oneUnknown — not stated by the sourceBlack
Operational conditions4 differ
Operating relative humidity (H-H)Differs10 - 90%20 - 80%
Operating temperature (T-T)Differs0 - 40 °C0 - 70 °C
Storage relative humidity (H-H)Differs10 - 95%5 - 95%
Storage temperature (T-T)Differs-20 - 70 °C-20 - 90 °C
Weight & dimensions1 differ
WeightDiffers865 g1.09 kg
WidthKnown for one270 mmUnknown — not stated by the source
DepthKnown for one140 mmUnknown — not stated by the source
HeightKnown for one35 mmUnknown — not stated by the source
Dimensions (WxDxH)Known for oneUnknown — not stated by the source211.84 x 181.76 x 29.49 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.