Product comparison · 2 uninterruptible power supplies (upss)

Vertiv Liebert ITA2 10kVA Rack 12MIN autonomy vs Vertiv Liebert PST5-500MT120 uninterruptible power supply (UPS) Standby (Offline) 0.5 kVA

Add a product
  • 16specifications compared
  • 14differ
  • 2identical
  • 38known for one product only

Key differences

  • UPS topology
    • Liebert ITA2 10kVA Rack 12MIN autonomy:Double-conversion (Online)
    • Liebert PST5-500MT120 uninterruptible power supply (UPS) Standby (Offline) 0.5 kVA:Standby (Offline)
  • Output power capacity
    • Liebert ITA2 10kVA Rack 12MIN autonomy:10 kVA
    • Liebert PST5-500MT120 uninterruptible power supply (UPS) Standby (Offline) 0.5 kVA:0.5 kVA
  • Output power
    • Liebert ITA2 10kVA Rack 12MIN autonomy:10000 W
    • Liebert PST5-500MT120 uninterruptible power supply (UPS) Standby (Offline) 0.5 kVA:300 W
  • Input operation voltage (min)
    • Liebert ITA2 10kVA Rack 12MIN autonomy:380 V
    • Liebert PST5-500MT120 uninterruptible power supply (UPS) Standby (Offline) 0.5 kVA:90 V
  • Input operation voltage (max)
    • Liebert ITA2 10kVA Rack 12MIN autonomy:415 V
    • Liebert PST5-500MT120 uninterruptible power supply (UPS) Standby (Offline) 0.5 kVA:145 V
  • Input frequency
    • Liebert ITA2 10kVA Rack 12MIN autonomy:40/70 Hz
    • Liebert PST5-500MT120 uninterruptible power supply (UPS) Standby (Offline) 0.5 kVA:60 Hz
  • Efficiency
    • Liebert ITA2 10kVA Rack 12MIN autonomy:96.2%
    • Liebert PST5-500MT120 uninterruptible power supply (UPS) Standby (Offline) 0.5 kVA:95%
  • Noise level
    • Liebert ITA2 10kVA Rack 12MIN autonomy:58 dB
    • Liebert PST5-500MT120 uninterruptible power supply (UPS) Standby (Offline) 0.5 kVA:40 dB

Side by side

Differences highlightedShow differences only (off)
Comparison of ITA2101A0000AAB, PST5-500MT120
54 specifications
Features8 differ
UPS topologyDiffersDouble-conversion (Online)Standby (Offline)
Output power capacityDiffers10 kVA0.5 kVA
Output powerDiffers10000 W300 W
WaveformKnown for oneUnknown — not stated by the sourcePulse width modulation (PWM)
Input operation voltage (min)Differs380 V90 V
Input operation voltage (max)Differs415 V145 V
Input frequencyDiffers40/70 Hz60 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source96 V
Output operation voltage (max)Known for oneUnknown — not stated by the source145 V
Output frequencyKnown for oneUnknown — not stated by the source60 Hz
Surge energy ratingKnown for oneUnknown — not stated by the source316 J
EfficiencyDiffers96.2%95%
Noise levelDiffers58 dB40 dB
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current, Overload, Short circuit
Output frequency regulationKnown for one50/60 HzUnknown — not stated by the source
Maximum currentKnown for one13 AUnknown — not stated by the source
Number of input phasesKnown for one3Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Overload capacity (5 minute)Known for one125%Unknown — not stated by the source
Overload capacity (1 minute)Known for one150%Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one2%Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Ports & interfacesidentical
AC outlet typesKnown for oneUnknown — not stated by the sourceNEMA 5-15R
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5-15P
AC outlets quantityKnown for oneUnknown — not stated by the source8 AC outlet(s)
USB portKnown for oneUnknown — not stated by the sourceYes
USB port typeKnown for oneUnknown — not stated by the sourceUSB Type-A/USB Type-B
Batteryidentical
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Battery capacityKnown for oneUnknown — not stated by the source5 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of battery cellsKnown for oneUnknown — not stated by the source1
Typical backup time at full loadKnown for oneUnknown — not stated by the source3 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source9 min
Design1 differ
Form factorDiffersRackmount/TowerCompact
Product colourBlackBlack
Control typeKnown for oneUnknown — not stated by the sourceButtons
Display typeLCDLCD
Rack capacityKnown for one3UUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 40 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-15 - 45 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourcecTUVus (UL 1778 5th Edition) CSA 22.2 no. 107.3:2014
Certificates1 differ
CertificationDiffersEN/IEC/AS 62040-2, VFI-SS-111, EN/IEC/AS 62040-1RFI / EMI FCC Part 15, Class B EN61000-4-5; Line to Neutral: Level 2; Line to Earth: Level 3
Weight & dimensions4 differ
WidthDiffers430 mm305 mm
DepthDiffers500 mm158.5 mm
HeightDiffers130 mm97 mm
WeightDiffers23 kg7.7 kg
Packaging dataidentical
Package widthKnown for oneUnknown — not stated by the source381 mm
Package depthKnown for oneUnknown — not stated by the source266 mm
Package heightKnown for oneUnknown — not stated by the source203 mm
Package weightKnown for oneUnknown — not stated by the source9 kg
Other featuresidentical
BypassKnown for oneBypass voltage tolerance (%) 20 - -40 Bypass frequency tolerance (%) ±20 (±10 selectable)Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons