Product comparison · 2 uninterruptible power supplies (upss)

Vertiv Liebert ITA2-08KRT208C uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA vs Vertiv Liebert PSI5-1500RT120 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA

Add a product
  • 25specifications compared
  • 21differ
  • 4identical
  • 36known for one product only

Key differences

  • UPS topology
    • Liebert ITA2-08KRT208C uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:Double-conversion (Online)
    • Liebert PSI5-1500RT120 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Line-Interactive
  • Output power capacity
    • Liebert ITA2-08KRT208C uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:8 kVA
    • Liebert PSI5-1500RT120 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
  • Output power
    • Liebert ITA2-08KRT208C uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:7200 W
    • Liebert PSI5-1500RT120 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1350 W
  • Input operation voltage (min)
    • Liebert ITA2-08KRT208C uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:96 V
    • Liebert PSI5-1500RT120 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:75 V
  • Input operation voltage (max)
    • Liebert ITA2-08KRT208C uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:144 V
    • Liebert PSI5-1500RT120 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:146 V
  • Input frequency
    • Liebert ITA2-08KRT208C uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:40/70 Hz
    • Liebert PSI5-1500RT120 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:55/65 Hz
  • Output operation voltage (min)
    • Liebert ITA2-08KRT208C uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:120 V
    • Liebert PSI5-1500RT120 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:100 V
  • Output operation voltage (max)
    • Liebert ITA2-08KRT208C uninterruptible power supply (UPS) Double-conversion (Online) 8 kVA:220 V
    • Liebert PSI5-1500RT120 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:125 V

Side by side

Differences highlightedShow differences only (on)
Comparison of ITA2-08KRT208C, PSI5-1500RT120
61 specifications
Features13 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers8 kVA1.5 kVA
Output powerDiffers7200 W1350 W
WaveformKnown for oneUnknown — not stated by the sourcePure sine
Input operation voltage (min)Differs96 V75 V
Input operation voltage (max)Differs144 V146 V
Input frequencyDiffers40/70 Hz55/65 Hz
Output operation voltage (min)Differs120 V100 V
Output operation voltage (max)Differs220 V125 V
Output frequencyDiffers60 Hz57/63 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Surge energy ratingKnown for oneUnknown — not stated by the source1372 J
Response timeDiffers60 ms6 ms
Number of input phasesDiffers31
Number of output phasesDiffers31
EfficiencyDiffers93%96%
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Input power factorKnown for one0.99Unknown — not stated by the source
Output power factorKnown for one0.9Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Ports & interfacesidentical
AC outlet typesKnown for oneUnknown — not stated by the sourceNEMA 5-15R
Power plugKnown for oneUnknown — not stated by the sourceNEMA 5-15
AC outlets quantityKnown for oneUnknown — not stated by the source6 AC outlet(s)
USB portKnown for oneUnknown — not stated by the sourceYes
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
USB port typeKnown for oneUnknown — not stated by the sourceUSB Type-B
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Cabling technologyKnown for oneUnknown — not stated by the source10/100Base-T
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
Batteryidentical
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Typical backup time at full loadKnown for oneUnknown — not stated by the source4 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source12 min
Battery recharge timeKnown for oneUnknown — not stated by the source4 h
Charging currentKnown for one3.5 AUnknown — not stated by the source
Design1 differ
Form factorDiffersTowerRackmount/Tower
Rack capacityKnown for oneUnknown — not stated by the source2U
Cable lengthKnown for oneUnknown — not stated by the source3 m
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 50 °C0 - 40 °C
Storage temperature (T-T)Differs0 - 50 °C-15 - 50 °C
Operating relative humidity (H-H)Differs5 - 95%20 - 90%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source20 - 90%
Packaging contentidentical
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
ManualKnown for oneUnknown — not stated by the sourceYes
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL 1778, c-UL-us
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceFCC, UL 497 B, ISTA
Weight & dimensions4 differ
WidthDiffers656 mm438 mm
DepthDiffers430 mm510 mm
HeightDiffers130 mm88 mm
WeightDiffers50.7 kg19.3 kg
Packaging dataidentical
Package widthKnown for oneUnknown — not stated by the source258 mm
Package depthKnown for oneUnknown — not stated by the source672 mm
Package heightKnown for oneUnknown — not stated by the source550 mm
Package weightKnown for oneUnknown — not stated by the source23.5 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons