Product comparison · 2 uninterruptible power supplies (upss)

Vertiv Liebert GXT4-3000RT230 uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA vs Vertiv GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA

Add a product
  • 29specifications compared
  • 13differ
  • 16identical
  • 21known for one product only

Key differences

  • Output power capacity
    • Liebert GXT4-3000RT230 uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:6 kVA
  • Output power
    • Liebert GXT4-3000RT230 uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:2700 W
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:4800 W
  • Input operation voltage (min)
    • Liebert GXT4-3000RT230 uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:115 V
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:120 V
  • Input operation voltage (max)
    • Liebert GXT4-3000RT230 uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:280 V
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:208 V
  • Input frequency
    • Liebert GXT4-3000RT230 uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:40 - 70 Hz
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:40/70 Hz
  • Output operation voltage (min)
    • Liebert GXT4-3000RT230 uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:200 V
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:120 V
  • Output operation voltage (max)
    • Liebert GXT4-3000RT230 uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:240 V
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:208 V
  • AC outlet types
    • Liebert GXT4-3000RT230 uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:C13 coupler, C19 coupler
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:Terminal

Side by side

Differences highlightedShow differences only (off)
Comparison of GXT4-3000RT230, GXT4-6000RT208
50 specifications
Features7 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers3 kVA6 kVA
Output powerDiffers2700 W4800 W
WaveformSineSine
Input operation voltage (min)Differs115 V120 V
Input operation voltage (max)Differs280 V208 V
Input frequencyDiffers40 - 70 Hz40/70 Hz
Output operation voltage (min)Differs200 V120 V
Output operation voltage (max)Differs240 V208 V
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Output voltage regulationKnown for one3%Unknown — not stated by the source
EfficiencyKnown for one88%Unknown — not stated by the source
Noise levelKnown for one48 dBUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Maximum currentKnown for oneUnknown — not stated by the source30 A
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
Ports & interfaces2 differ
AC outlet typesDiffersC13 coupler, C19 couplerTerminal
Power plugDiffersC20 couplerTerminal
AC outlets quantityKnown for one7 AC outlet(s)Unknown — not stated by the source
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
RS-232 portsKnown for one2Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Batteryidentical
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery capacity9 Ah9 Ah
Battery voltage12 V12 V
Number of batteries supported66
Typical backup time at full loadKnown for one3 minUnknown — not stated by the source
Typical backup time at half loadKnown for one12 minUnknown — not stated by the source
Battery recharge timeKnown for one3 hUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Designidentical
Form factorRackmount/TowerRackmount/Tower
Product colourBlackBlack
Cooling typeKnown for oneActiveUnknown — not stated by the source
Display typeLCDLCD
LED indicatorsYesYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)-15 - 50 °C-15 - 50 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Sustainabilityidentical
Sustainability certificatesENERGY STARENERGY STAR
Safety regulation & standards1 differ
SafetyDiffersIEC/EN/AS 62040-1:2008, GS mark, UL 1778UL 1778, c-U
Weight & dimensions3 differ
Width430 mm430 mm
DepthDiffers602 mm662 mm
HeightDiffers85 mm173 mm
WeightDiffers32.4 kg69.9 kg
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceFCC A, IEEE/ANSI C62.41 A

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons