Product comparison · 2 uninterruptible power supplies (upss)

Vertiv Liebert AS4B0NCYGNNXLKB uninterruptible power supply (UPS) 10 kVA vs Vertiv Liebert AS6B0NCVGNNXLKB uninterruptible power supply (UPS) 10 kVA

Add a product
  • 27specifications compared
  • 7differ
  • 20identical
  • 1known for one product only

Key differences

The Vertiv Liebert AS4B0NCYGNNXLKB uninterruptible power supply (UPS) 10 kVA has 1,197 BTU/h more heat dissipation than the Vertiv Liebert AS6B0NCVGNNXLKB uninterruptible power supply (UPS) 10 kVA (7965 BTU/h vs 6768 BTU/h). The Vertiv Liebert AS6B0NCVGNNXLKB uninterruptible power supply (UPS) 10 kVA has 1.3% more efficiency than the Vertiv Liebert AS4B0NCYGNNXLKB uninterruptible power supply (UPS) 10 kVA (91% vs 89.7%). The Vertiv Liebert AS4B0NCYGNNXLKB uninterruptible power supply (UPS) 10 kVA has 16 min more typical backup time at full load than the Vertiv Liebert AS6B0NCVGNNXLKB uninterruptible power supply (UPS) 10 kVA (21 min vs 5 min).

  • Heat dissipation
    • Liebert AS4B0NCYGNNXLKB uninterruptible power supply (UPS) 10 kVA:7965 BTU/h
    • Liebert AS6B0NCVGNNXLKB uninterruptible power supply (UPS) 10 kVA:6768 BTU/h
  • Efficiency
    • Liebert AS4B0NCYGNNXLKB uninterruptible power supply (UPS) 10 kVA:89.7%
    • Liebert AS6B0NCVGNNXLKB uninterruptible power supply (UPS) 10 kVA:91%
  • Typical backup time at full load
    • Liebert AS4B0NCYGNNXLKB uninterruptible power supply (UPS) 10 kVA:21 min
    • Liebert AS6B0NCVGNNXLKB uninterruptible power supply (UPS) 10 kVA:5 min
  • Typical backup time at half load
    • Liebert AS4B0NCYGNNXLKB uninterruptible power supply (UPS) 10 kVA:51 min
    • Liebert AS6B0NCVGNNXLKB uninterruptible power supply (UPS) 10 kVA:16 min
  • Height
    • Liebert AS4B0NCYGNNXLKB uninterruptible power supply (UPS) 10 kVA:1240 mm
    • Liebert AS6B0NCVGNNXLKB uninterruptible power supply (UPS) 10 kVA:970 mm
  • Weight
    • Liebert AS4B0NCYGNNXLKB uninterruptible power supply (UPS) 10 kVA:417.3 kg
    • Liebert AS6B0NCVGNNXLKB uninterruptible power supply (UPS) 10 kVA:317.5 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of AS4B0NCYGNNXLKB, AS6B0NCVGNNXLKB
28 specifications
Features2 differ
Output power capacity10 kVA10 kVA
Output power9000 W9000 W
Input operation voltage (min)200 V200 V
Input operation voltage (max)240 V240 V
Input frequency40/70 Hz40/70 Hz
Output operation voltage (min)100 V100 V
Output operation voltage (max)240 V240 V
Output frequency50/60 Hz50/60 Hz
Output voltage regulation±3%±3%
Heat dissipationDiffers7965 BTU/h6768 BTU/h
EfficiencyDiffers89.7%91%
Input power factor0.990.99
Power protection featuresOverloadOverload
Battery2 differ
Battery voltage1.67 V1.67 V
Typical backup time at full loadDiffers21 min5 min
Typical backup time at half loadDiffers51 min16 min
Designidentical
Product colourBlackBlack
Cooling typeActiveActive
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Certificatesidentical
Compliance certificatesREACH, RoHS, WEEEREACH, RoHS, WEEE
Safety regulation & standards1 differ
SafetyDiffersIEC/EN/AS 62040-1:2008, UL 1778 4th Ed & CSA 22.2 No. 107.1UL 1778 4th Ed and CSA 22.2 No. 107.1
Weight & dimensions2 differ
Width440 mm440 mm
Depth850 mm850 mm
HeightDiffers1240 mm970 mm
WeightDiffers417.3 kg317.5 kg
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source335.7 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.