Key differences

The Salicru SLC-8000-TWIN RT3 B0 has 2 kVA more output power capacity than the Salicru SLC-6000-TWIN RT3 B1 (8 kVA vs 6 kVA). The Salicru SLC-8000-TWIN RT3 B0 has 2,000 W more output power than the Salicru SLC-6000-TWIN RT3 B1 (8000 W vs 6000 W). The Salicru SLC-6000-TWIN RT3 B1 has 50 V more input operation voltage (min) than the Salicru SLC-8000-TWIN RT3 B0 (160 V vs 110 V).

  • Output power capacity
    • SLC-6000-TWIN RT3 B1:6 kVA
    • SLC-8000-TWIN RT3 B0:8 kVA
  • Output power
    • SLC-6000-TWIN RT3 B1:6000 W
    • SLC-8000-TWIN RT3 B0:8000 W
  • Input operation voltage (min)
    • SLC-6000-TWIN RT3 B1:160 V
    • SLC-8000-TWIN RT3 B0:110 V
  • Noise level
    • SLC-6000-TWIN RT3 B1:55 dB
    • SLC-8000-TWIN RT3 B0:60 dB
  • Height
    • SLC-6000-TWIN RT3 B1:86.3 mm
    • SLC-8000-TWIN RT3 B0:220 mm
  • Weight
    • SLC-6000-TWIN RT3 B1:13.6 kg
    • SLC-8000-TWIN RT3 B0:64.5 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of SLC-6000-TWIN RT3 B1, SLC-8000-TWIN RT3 B0
43 specifications
Features4 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers6 kVA8 kVA
Output powerDiffers6000 W8000 W
Input operation voltage (min)Differs160 V110 V
Input operation voltage (max)276 V276 V
Input frequency40/70 Hz40/70 Hz
Output operation voltage (min)220 V220 V
Output operation voltage (max)240 V240 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
Efficiency (On-line mode)95%95%
Efficiency (ECO mode)98%98%
Power factorKnown for oneUnknown — not stated by the source1
Input power factor0.990.99
Output power factor11
ECO modeYesYes
Emergency Power Off (EPO)YesYes
Output voltage Total Harmonic Distortion (THD)1%1%
Input current Total Harmonic Distortion (THD)3%3%
Noise levelDiffers55 dB60 dB
Power source typeKnown for oneUnknown — not stated by the sourceAC
Ports & interfacesidentical
USB portYesYes
USB 2.0 ports quantity11
Serial interfaceYesYes
Serial interface typeRS-232RS-232
RS-232 ports11
Ethernet LAN (RJ-45) ports11
AC outlet typesKnown for oneC13 coupler, C19 coupler, TerminalUnknown — not stated by the source
SmartSlotKnown for oneYesUnknown — not stated by the source
Batteryidentical
Cold startYesYes
Designidentical
Form factorRackmount/TowerRackmount/Tower
Product colourBlackBlack
LED indicatorsKnown for oneYesUnknown — not stated by the source
CompatibilityKnown for oneEN-IEC 62040-1 EN 62040-2(C3) VFI-SS-111 (IEC 62040-3) ISO 9001, ISO 14001, ISO 45001Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)0 - 50 °C0 - 50 °C
Operating altitude0 - 3000 m0 - 3000 m
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceEN-IEC 62040-1 EN 62040-2(C3) VFI-SS-111 (IEC 62040-3) ISO 9001, ISO 14001, ISO 45001
Weight & dimensions2 differ
Width438 mm438 mm
Depth570 mm570 mm
HeightDiffers86.3 mm220 mm
WeightDiffers13.6 kg64.5 kg
Packaging contentidentical
Batteries includedKnown for oneNoUnknown — not stated by the source