Product comparison · 2 uninterruptible power supplies (upss)

Salicru SLC-6000 TWIN PRO (B1) vs Salicru SLC-8000-TWIN/3 PRO (B1)

Add a product
  • 43specifications compared
  • 9differ
  • 34identical
  • 1known for one product only

Key differences

The Salicru SLC-8000-TWIN/3 PRO (B1) has 2 kVA more output power capacity than the Salicru SLC-6000 TWIN PRO (B1) (8 kVA vs 6 kVA). The Salicru SLC-8000-TWIN/3 PRO (B1) has 1,800 W more output power than the Salicru SLC-6000 TWIN PRO (B1) (7200 W vs 5400 W). The Salicru SLC-8000-TWIN/3 PRO (B1) has 2 more input phases than the Salicru SLC-6000 TWIN PRO (B1) (3 vs 1). Package dimensions (WxDxH): 708 x 1700 x 850 mm on the Salicru SLC-6000 TWIN PRO (B1), 708 x 2550 x 850 mm on the Salicru SLC-8000-TWIN/3 PRO (B1).

  • Output power capacity
    • SLC-6000 TWIN PRO (B1):6 kVA
    • SLC-8000-TWIN/3 PRO (B1):8 kVA
  • Output power
    • SLC-6000 TWIN PRO (B1):5400 W
    • SLC-8000-TWIN/3 PRO (B1):7200 W
  • Number of input phases
    • SLC-6000 TWIN PRO (B1):1
    • SLC-8000-TWIN/3 PRO (B1):3
  • Efficiency
    • SLC-6000 TWIN PRO (B1):92%
    • SLC-8000-TWIN/3 PRO (B1):93%
  • Noise level
    • SLC-6000 TWIN PRO (B1):50 dB
    • SLC-8000-TWIN/3 PRO (B1):55 dB
  • Depth
    • SLC-6000 TWIN PRO (B1):520 mm
    • SLC-8000-TWIN/3 PRO (B1):780 mm
  • Weight
    • SLC-6000 TWIN PRO (B1):153 kg
    • SLC-8000-TWIN/3 PRO (B1):302 kg
  • Package weight
    • SLC-6000 TWIN PRO (B1):158 kg
    • SLC-8000-TWIN/3 PRO (B1):310 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of SLC-6000 TWIN PRO (B1), SLC-8000-TWIN/3 PRO (B1)
44 specifications
Features5 differ
Output power capacityDiffers6 kVA8 kVA
Output powerDiffers5400 W7200 W
Input operation voltage (min)110 V110 V
Input operation voltage (max)276 V276 V
Input frequency50/60 Hz50/60 Hz
Output operation voltage (min)200 V200 V
Output operation voltage (max)240 V240 V
Output frequency regulation0.2 Hz0.2 Hz
Output voltage regulation2%2%
Number of input phasesDiffers13
Number of output phases11
EfficiencyDiffers92%93%
Power factor0.990.99
Crest factor3:13:1
Emergency Power Off (EPO)NoNo
Output voltage Total Harmonic Distortion (THD)2%2%
Input current Total Harmonic Distortion (THD)5%5%
Noise levelDiffers50 dB55 dB
Audible alarm(s)YesYes
Ports & interfacesidentical
AC outlets quantityKnown for oneUnknown — not stated by the source2 AC outlet(s)
USB 2.0 ports quantity11
RS-232 ports11
Batteryidentical
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery voltage12 V12 V
Cold startYesYes
Designidentical
Form factorTowerTower
Product colourBlackBlack
Cooling typeActiveActive
Built-in fanYesYes
Display typeLCDLCD
LED indicatorsYesYes
Operational conditionsidentical
Operating temperature (T-T)0 - 45 °C0 - 45 °C
Storage temperature (T-T)-15 - 50 °C-15 - 50 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 1000 m0 - 1000 m
Safety regulation & standardsidentical
SafetyEN-62040-1, EN-60950-1, EN-60529EN-62040-1, EN-60950-1, EN-60529
Certificatesidentical
CertificationEN-62040-2EN-62040-2
Weight & dimensions2 differ
Width560 mm560 mm
DepthDiffers520 mm780 mm
Height708 mm708 mm
WeightDiffers153 kg302 kg
Packaging data1 differ
Bundled softwareWinPowerWinPower
Package weightDiffers158 kg310 kg
Other features1 differ
Package dimensions (WxDxH)Differs708 x 1700 x 850 mm708 x 2550 x 850 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons