Product comparison · 2 uninterruptible power supplies (upss)

Salicru SLC-15000-TWIN PRO3 MULTI vs Salicru SLC 20000 TWIN RT3 MULTI

Add a product
  • 47specifications compared
  • 9differ
  • 38identical
  • 7known for one product only

Key differences

The Salicru SLC 20000 TWIN RT3 MULTI has 5 kVA more output power capacity than the Salicru SLC-15000-TWIN PRO3 MULTI (20 kVA vs 15 kVA). The Salicru SLC 20000 TWIN RT3 MULTI has 5,000 W more output power than the Salicru SLC-15000-TWIN PRO3 MULTI (20000 W vs 15000 W). The Salicru SLC 20000 TWIN RT3 MULTI has 0.2% more efficiency (ECO mode) than the Salicru SLC-15000-TWIN PRO3 MULTI (99% vs 98.8%). Input frequency: 40 - 70 Hz on the Salicru SLC-15000-TWIN PRO3 MULTI, 50/60 Hz on the Salicru SLC 20000 TWIN RT3 MULTI. Form factor: Tower on the Salicru SLC-15000-TWIN PRO3 MULTI, Rackmount/Tower on the Salicru SLC 20000 TWIN RT3 MULTI.

  • Output power capacity
    • SLC-15000-TWIN PRO3 MULTI:15 kVA
    • SLC 20000 TWIN RT3 MULTI:20 kVA
  • Output power
    • SLC-15000-TWIN PRO3 MULTI:15000 W
    • SLC 20000 TWIN RT3 MULTI:20000 W
  • Input frequency
    • SLC-15000-TWIN PRO3 MULTI:40 - 70 Hz
    • SLC 20000 TWIN RT3 MULTI:50/60 Hz
  • Efficiency (ECO mode)
    • SLC-15000-TWIN PRO3 MULTI:98.8%
    • SLC 20000 TWIN RT3 MULTI:99%
  • Form factor
    • SLC-15000-TWIN PRO3 MULTI:Tower
    • SLC 20000 TWIN RT3 MULTI:Rackmount/Tower
  • Width
    • SLC-15000-TWIN PRO3 MULTI:300 mm
    • SLC 20000 TWIN RT3 MULTI:438 mm
  • Depth
    • SLC-15000-TWIN PRO3 MULTI:699 mm
    • SLC 20000 TWIN RT3 MULTI:592 mm
  • Weight
    • SLC-15000-TWIN PRO3 MULTI:129.4 kg
    • SLC 20000 TWIN RT3 MULTI:24.8 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of SLC-15000-TWIN PRO3 MULTI, SLC 20000 TWIN RT3 MULTI
54 specifications
Features5 differ
Output power capacityDiffers15 kVA20 kVA
Output powerDiffers15000 W20000 W
Input frequencyDiffers40 - 70 Hz50/60 Hz
Efficiency (ECO mode)Differs98.8%99%
Power protection featuresDiffersOver voltage, Under total voltage, OverheatingOver voltage, Under voltage, Overheating
Input frequency converterKnown for oneUnknown — not stated by the sourceYes
Temperature voltage compensationKnown for oneYesUnknown — not stated by the source
Ports & interfacesidentical
AC outlet typesKnown for oneType FUnknown — not stated by the source
AC outlets quantityKnown for one1 AC outlet(s)Unknown — not stated by the source
Batteryidentical
Automatic battery testKnown for oneUnknown — not stated by the sourceYes
Design1 differ
Form factorDiffersTowerRackmount/Tower
Control typeKnown for oneUnknown — not stated by the sourceTouch
Weight & dimensions3 differ
WidthDiffers300 mm438 mm
DepthDiffers699 mm592 mm
HeightKnown for oneUnknown — not stated by the source129 mm
WeightDiffers129.4 kg24.8 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons