Product comparison · 2 uninterruptible power supplies (upss)

Salicru SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA vs Salicru SLC TWIN

Add a product
  • 18specifications compared
  • 8differ
  • 10identical
  • 17known for one product only

Key differences

The Salicru SLC TWIN has 1.5 kVA more output power capacity than the Salicru SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA (3 kVA vs 1.5 kVA). The Salicru SLC TWIN has 1,050 W more output power than the Salicru SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA (2100 W vs 1050 W). The Salicru SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA has 0.03 more power factor than the Salicru SLC TWIN (0.98 vs 0.95). Form factor: Rackmount/Tower on the Salicru SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA, Tower on the Salicru SLC TWIN. Certification: EN, VFI, CE, ISO on the Salicru SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA, CE, TÜV on the Salicru SLC TWIN.

  • Output power capacity
    • SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA:1.5 kVA
    • SLC TWIN:3 kVA
  • Output power
    • SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA:1050 W
    • SLC TWIN:2100 W
  • Power factor
    • SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA:0.98
    • SLC TWIN:0.95
  • Noise level
    • SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA:45 dB
    • SLC TWIN:60 dB
  • Battery recharge time
    • SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA:7 h
    • SLC TWIN:8 h
  • Form factor
    • SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA:Rackmount/Tower
    • SLC TWIN:Tower
  • Certification
    • SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA:EN, VFI, CE, ISO
    • SLC TWIN:CE, TÜV
  • Weight
    • SLC-1500-TWIN uninterruptible power supply (UPS) 1.5 kVA:30 kg
    • SLC TWIN:32 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of SLC-1500-TWIN, SLC TWIN
35 specifications
Features4 differ
Output power capacityDiffers1.5 kVA3 kVA
Output powerDiffers1050 W2100 W
Input operation voltage (min)Known for one176 VUnknown — not stated by the source
Input operation voltage (max)Known for one276 VUnknown — not stated by the source
Power factorDiffers0.980.95
Output voltage Total Harmonic Distortion (THD)Known for one6%Unknown — not stated by the source
Noise levelDiffers45 dB60 dB
Power protection featuresKnown for oneOver voltage, Under voltageUnknown — not stated by the source
Ports & interfacesidentical
AC outlets quantityKnown for one3 AC outlet(s)Unknown — not stated by the source
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Battery1 differ
Battery recharge timeDiffers7 h8 h
Hot-swap batteryKnown for oneNoUnknown — not stated by the source
Design1 differ
Form factorDiffersRackmount/TowerTower
Product colourKnown for oneBlackUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditionsidentical
Operating altitudeKnown for one0 - 2400 mUnknown — not stated by the source
Certificates1 differ
CertificationDiffersEN, VFI, CE, ISOCE, TÜV
Weight & dimensions1 differ
WeightDiffers30 kg32 kg
Other featuresidentical
Compatible operating systemsKnown for oneWindows OS Linux OS Mac OSUnknown — not stated by the source
Mac compatibilityKnown for oneYesUnknown — not stated by the source
Nominal output voltageKnown for one220-240 VUnknown — not stated by the source
Relative humidityKnown for one0 - 95%Unknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceEN 62040-1; EN 60950-1; EN 60529

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.