Product comparison · 2 uninterruptible power supplies (upss)

Salicru SPS 1500 ADV RT2 B1 vs Salicru SPS 3000 ADV RT2 B1

Add a product
  • 65specifications compared
  • 7differ
  • 58identical
  • 1known for one product only

Key differences

  • Output power capacity
    • SPS 1500 ADV RT2 B1:1.5 kVA
    • SPS 3000 ADV RT2 B1:3 kVA
  • Output power
    • SPS 1500 ADV RT2 B1:1350 W
    • SPS 3000 ADV RT2 B1:2700 W
  • AC outlets quantity
    • SPS 1500 ADV RT2 B1:8 AC outlet(s)
    • SPS 3000 ADV RT2 B1:9 AC outlet(s)
  • Number of output IEC jumpers
    • SPS 1500 ADV RT2 B1:8
    • SPS 3000 ADV RT2 B1:9
  • Form factor
    • SPS 1500 ADV RT2 B1:Rackmount/Tower
    • SPS 3000 ADV RT2 B1:Tower
  • Depth
    • SPS 1500 ADV RT2 B1:510 mm
    • SPS 3000 ADV RT2 B1:630 mm
  • Weight
    • SPS 1500 ADV RT2 B1:10.8 kg
    • SPS 3000 ADV RT2 B1:11.9 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of 6A0CA000008, 6A0CA000010
66 specifications
A

Salicru

SPS 1500 ADV RT2 B1

Model 6A0CA000008

View product
B

Salicru

SPS 3000 ADV RT2 B1

Model 6A0CA000010

View product
Features2 differ
UPS topologyLine-InteractiveLine-Interactive
Output power capacityDiffers1.5 kVA3 kVA
Output powerDiffers1350 W2700 W
WaveformPure sinePure sine
Input operation voltage (min)170 V170 V
Input operation voltage (max)280 V280 V
Input frequency50/60 Hz50/60 Hz
Output operation voltage (min)208 V208 V
Output operation voltage (max)240 V240 V
Output frequency50/60 Hz50/60 Hz
Output frequency regulation0.1 Hz0.1 Hz
Output voltage regulation1.5%1.5%
Automatic Voltage Regulation (AVR)YesYes
Output power factor0.90.9
Emergency Power Off (EPO)YesYes
Overload capacity (5 minute)120%120%
Overload capacity (1 minute)120%120%
Overload capacity (10 seconds)150%150%
Total Harmonic Distortion (THD) (linear load)2%2%
Total Harmonic Distortion (THD) (non-linear load)5%5%
Noise level45 dB45 dB
Surge protectionYesYes
Surge protection featuresDigital Subscriber Line (DSL), Fax, ModemDigital Subscriber Line (DSL), Fax, Modem
Power protection featuresUnder voltageUnder voltage
Auto power offYesYes
Site wiring fault detectionYesYes
Temperature voltage compensationYesYes
Maintenance-freeYesYes
Ports & interfaces2 differ
AC outlet typesC13 couplerC13 coupler
Power plugC14 couplerC14 coupler
AC outlets quantityDiffers8 AC outlet(s)9 AC outlet(s)
Number of output IEC jumpersDiffers89
USB portYesYes
USB 2.0 ports quantity11
Serial interfaceYesYes
Serial interface typeRS-232RS-232
RS-232 ports11
Ethernet LAN (RJ-45) ports22
Emergency Power Off (EPO) connectorYesYes
SmartSlotYesYes
Programmable socketsYesYes
Batteryidentical
Battery technologyLead-Calcium (Pb-Ca)Lead-Calcium (Pb-Ca)
Battery recharge time(90%)4 h4 h
Automatic battery testYesYes
Cold startYesYes
Charge typeConstant current/Constant voltageConstant current/Constant voltage
Design1 differ
Form factorDiffersRackmount/TowerTower
Product colourBlackBlack
Rack capacity2U2U
Cooling typeActiveActive
Built-in fanYesYes
Fan speed controlYesYes
Display typeLCDLCD
LED indicatorsYesYes
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Operating altitude0 - 5000 m0 - 5000 m
Safety regulation & standardsidentical
SafetyEN 62040-1:2008, EN 62040-2:2006(C2), EN 62040-3:2011EN 62040-1:2008, EN 62040-2:2006(C2), EN 62040-3:2011
Certificatesidentical
CertificationISO-9001, ISO-14001ISO-9001, ISO-14001
Weight & dimensions2 differ
Width438 mm438 mm
DepthDiffers510 mm630 mm
Height88 mm88 mm
WeightDiffers10.8 kg11.9 kg
Logistics dataidentical
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source
Other featuresidentical
Battery typeAGMAGM
Compatible operating systemsWindows, Linux, MacWindows, Linux, Mac

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons