Product comparison · 2 uninterruptible power supplies (upss)

Salicru SLC-8000-TWIN PRO2 B1 vs Salicru SPS 1100 ADV RT2

Add a product
  • 48specifications compared
  • 22differ
  • 26identical
  • 37known for one product only

Key differences

  • UPS topology
    • SLC-8000-TWIN PRO2 B1:Double-conversion (Online)
    • SPS 1100 ADV RT2:Line-Interactive
  • Output power capacity
    • SLC-8000-TWIN PRO2 B1:8 kVA
    • SPS 1100 ADV RT2:1.1 kVA
  • Output power
    • SLC-8000-TWIN PRO2 B1:8000 W
    • SPS 1100 ADV RT2:990 W
  • Input operation voltage (min)
    • SLC-8000-TWIN PRO2 B1:110 V
    • SPS 1100 ADV RT2:170 V
  • Input operation voltage (max)
    • SLC-8000-TWIN PRO2 B1:276 V
    • SPS 1100 ADV RT2:280 V
  • Output frequency regulation
    • SLC-8000-TWIN PRO2 B1:4 Hz
    • SPS 1100 ADV RT2:0.1 Hz
  • Output voltage regulation
    • SLC-8000-TWIN PRO2 B1:1%
    • SPS 1100 ADV RT2:1.5%
  • Overload capacity (1 minute)
    • SLC-8000-TWIN PRO2 B1:130%
    • SPS 1100 ADV RT2:120%

Side by side

Differences highlightedShow differences only (on)
Comparison of 699CB000009, 6A0CA000002
85 specifications
A

Salicru

SLC-8000-TWIN PRO2 B1

Model 699CB000009

View product
B

Salicru

SPS 1100 ADV RT2

Model 6A0CA000002

View product
Features12 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers8 kVA1.1 kVA
Output powerDiffers8000 W990 W
Input operation voltage (min)Differs110 V170 V
Input operation voltage (max)Differs276 V280 V
Output frequency regulationDiffers4 Hz0.1 Hz
Output voltage regulationDiffers1%1.5%
Number of input phasesKnown for one1Unknown — not stated by the source
Number of output phasesKnown for one1Unknown — not stated by the source
Efficiency (On-line mode)Known for one94%Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Output power factorKnown for one1Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
ECO modeKnown for oneYesUnknown — not stated by the source
Overload capacity (10 minutes)Known for one110%Unknown — not stated by the source
Overload capacity (1 minute)Differs130%120%
Output voltage Total Harmonic Distortion (THD)Known for one4%Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one4%Unknown — not stated by the source
Total Harmonic Distortion (THD) (linear load)Differs1%2%
Total Harmonic Distortion (THD) (non-linear load)Differs4%5%
Noise levelDiffers60 dB45 dB
Power protection featuresDiffersUnder voltageUnder current, Under voltage
Maximum number of paralleling UPSsKnown for one3Unknown — not stated by the source
Input frequency converterKnown for oneYesUnknown — not stated by the source
Synchronisation with mainsKnown for one4 HzUnknown — not stated by the source
Synchronisation without mainsKnown for one0.1 HzUnknown — not stated by the source
WaveformKnown for oneUnknown — not stated by the sourcePure sine
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Power factorKnown for oneUnknown — not stated by the source0.9
Overload capacity (5 minute)Known for oneUnknown — not stated by the source120%
Overload capacity (10 seconds)Known for oneUnknown — not stated by the source150%
Surge protection featuresKnown for oneUnknown — not stated by the sourceDigital Subscriber Line (DSL), Fax, Modem
Auto power offKnown for oneUnknown — not stated by the sourceYes
Site wiring fault detectionKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers2 AC outlet(s)8 AC outlet(s)
Number of output IEC jumpersDiffers28
Parallel ports quantityKnown for one3Unknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceC14 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
SmartSlotKnown for oneUnknown — not stated by the sourceYes
Programmable socketsKnown for oneUnknown — not stated by the sourceYes
Batteryidentical
Battery recharge timeKnown for one7 hUnknown — not stated by the source
Off-mode chargingKnown for oneYesUnknown — not stated by the source
Battery recharge time(90%)Known for oneUnknown — not stated by the source4 h
Charge typeKnown for oneUnknown — not stated by the sourceConstant current/Constant voltage
Design1 differ
Form factorDiffersTowerRackmount/Tower
Rack capacityKnown for oneUnknown — not stated by the source2U
Fan speed controlKnown for oneUnknown — not stated by the sourceYes
Operational conditions1 differ
Operating altitudeDiffers0 - 2400 m0 - 5000 m
Safety regulation & standards1 differ
SafetyDiffersEN 62040-1; EN 60950-1EN 62040-1:2008
Certificates1 differ
CertificationDiffersEN 62040-2 C3 EN 62040-3 ISO-9001 ISO-14001EN 62040-2:2006(C2), EN 62040-3:2011, ISO-9001, ISO-14001
Weight & dimensions4 differ
WidthDiffers250 mm438 mm
DepthDiffers592 mm410 mm
HeightDiffers576 mm88 mm
WeightDiffers27 kg13.4 kg
Other featuresidentical
BypassKnown for oneHybrid, NillUnknown — not stated by the source
I/O portsKnown for oneIntelligent slotUnknown — not stated by the source
Compatible operating systemsKnown for oneUnknown — not stated by the sourceWindows, Linux, Mac

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons