Product comparison · 2 uninterruptible power supplies (upss)

Salicru SLC-1500-TWIN RT2 B1 vs Salicru SLC-6000-TWIN RT2 B1

Add a product
  • 45specifications compared
  • 15differ
  • 30identical
  • 12known for one product only

Key differences

  • Output power capacity
    • SLC-1500-TWIN RT2 B1:1.5 kVA
    • SLC-6000-TWIN RT2 B1:6 kVA
  • Output power
    • SLC-1500-TWIN RT2 B1:1500 W
    • SLC-6000-TWIN RT2 B1:6000 W
  • Input operation voltage (min)
    • SLC-1500-TWIN RT2 B1:200 V
    • SLC-6000-TWIN RT2 B1:208 V
  • Output operation voltage (min)
    • SLC-1500-TWIN RT2 B1:200 V
    • SLC-6000-TWIN RT2 B1:208 V
  • Output frequency regulation
    • SLC-1500-TWIN RT2 B1:3 Hz
    • SLC-6000-TWIN RT2 B1:4 Hz
  • Efficiency
    • SLC-1500-TWIN RT2 B1:91%
    • SLC-6000-TWIN RT2 B1:94%
  • Output voltage Total Harmonic Distortion (THD)
    • SLC-1500-TWIN RT2 B1:2%
    • SLC-6000-TWIN RT2 B1:1%
  • Input current Total Harmonic Distortion (THD)
    • SLC-1500-TWIN RT2 B1:5%
    • SLC-6000-TWIN RT2 B1:4%

Side by side

Differences highlightedShow differences only (on)
Comparison of 698CA000008, 698CC000003
57 specifications
A

Salicru

SLC-1500-TWIN RT2 B1

Model 698CA000008

View product
B

Salicru

SLC-6000-TWIN RT2 B1

Model 698CC000003

View product
Features9 differ
Output power capacityDiffers1.5 kVA6 kVA
Output powerDiffers1500 W6000 W
Input operation voltage (min)Differs200 V208 V
Output operation voltage (min)Differs200 V208 V
Output frequency regulationDiffers3 Hz4 Hz
EfficiencyDiffers91%94%
Overload capacity (10 minutes)Known for one110%Unknown — not stated by the source
Overload capacity (5 minute)Known for one130%Unknown — not stated by the source
Overload capacity (1 minute)Known for one130%Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Differs2%1%
Input current Total Harmonic Distortion (THD)Differs5%4%
Total Harmonic Distortion (THD) (linear load)Known for one2%Unknown — not stated by the source
Total Harmonic Distortion (THD) (non-linear load)Known for one4%Unknown — not stated by the source
Noise levelDiffers55 dB60 dB
Input frequency converterKnown for oneYesUnknown — not stated by the source
Synchronisation with mainsKnown for one3 HzUnknown — not stated by the source
Synchronisation without mainsKnown for one0.1 HzUnknown — not stated by the source
Temperature voltage compensationKnown for oneYesUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesDiffersC13 couplerTerminal
AC outlets quantityKnown for one8 AC outlet(s)Unknown — not stated by the source
Programmable socketsKnown for oneYesUnknown — not stated by the source
Battery1 differ
Battery recharge timeDiffers3 h9 h
Charge typeKnown for oneI/UUnknown — not stated by the source
Design1 differ
Rack capacityDiffers2U4U
Safety regulation & standards1 differ
SafetyDiffersEN 62040-1:2008, EN 62040-2:2006(C2), EN 62040-3:2011EN 62040-1:2008, EN 62040-2:2006(C3), EN 62040-3:2011
Weight & dimensions2 differ
DepthDiffers405 mm630 mm
WeightDiffers8.1 kg18 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons