Product comparison · 2 uninterruptible power supplies (upss)

Nilox Line Inter vs Nilox Server Pro

Add a product
  • 33specifications compared
  • 11differ
  • 22identical
  • 5known for one product only

Key differences

  • Output power capacity
    • Line Inter:1 kVA
    • Server Pro:1.1 kVA
  • Output power
    • Line Inter:500 W
    • Server Pro:600 W
  • AC outlets quantity
    • Line Inter:3 AC outlet(s)
    • Server Pro:6 AC outlet(s)
  • Battery capacity
    • Line Inter:9 Ah
    • Server Pro:7 Ah
  • Number of batteries supported
    • Line Inter:1
    • Server Pro:2
  • Form factor
    • Line Inter:Tower
    • Server Pro:Rackmount/Tower
  • Cooling type
    • Line Inter:Passive
    • Server Pro:Active
  • Width
    • Line Inter:100 mm
    • Server Pro:86 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of Line Inter, Server Pro
38 specifications
Features2 differ
UPS topologyLine-InteractiveLine-Interactive
Output power capacityDiffers1 kVA1.1 kVA
Output powerDiffers500 W600 W
WaveformSineSine
Input operation voltage (min)200 V200 V
Input operation voltage (max)240 V240 V
Output operation voltage (min)220 V220 V
Output operation voltage (max)240 V240 V
Output frequency regulation60 Hz60 Hz
Automatic Voltage Regulation (AVR)YesYes
Response time4 ms4 ms
Efficiency92%92%
Noise level40 dB40 dB
Audible alarm(s)YesYes
Ports & interfaces1 differ
AC outlet typesC13 couplerC13 coupler
Power plugKnown for oneUnknown — not stated by the sourceC14 coupler
AC outlets quantityDiffers3 AC outlet(s)6 AC outlet(s)
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
RS-232 portsKnown for oneUnknown — not stated by the source1
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source2
Number of type F outputsKnown for one1Unknown — not stated by the source
Battery2 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery capacityDiffers9 Ah7 Ah
Battery voltage12 V12 V
Number of batteries supportedDiffers12
Typical backup time at full load2 min2 min
Typical backup time at half load8 min8 min
Battery recharge time8 h8 h
Design2 differ
Form factorDiffersTowerRackmount/Tower
Product colourBlackBlack
Cooling typeDiffersPassiveActive
LED indicatorsYesYes
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Weight & dimensions4 differ
WidthDiffers100 mm86 mm
DepthDiffers280 mm330 mm
HeightDiffers145 mm390 mm
WeightDiffers5 kg11 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.