Product comparison · 2 uninterruptible power supplies (upss)

Legrand UPS DAKER DK PLUS 10000VA NO BATT vs Legrand UPS DAKER DK PLUS 6000VA NO BATT

Add a product
  • 61specifications compared
  • 16differ
  • 45identical
  • 1known for one product only

Key differences

  • Output power capacity
    • UPS DAKER DK PLUS 10000VA NO BATT:10 kVA
    • UPS DAKER DK PLUS 6000VA NO BATT:6 kVA
  • Output power
    • UPS DAKER DK PLUS 10000VA NO BATT:10000 W
    • UPS DAKER DK PLUS 6000VA NO BATT:6000 W
  • Efficiency (ECO mode)
    • UPS DAKER DK PLUS 10000VA NO BATT:98%
    • UPS DAKER DK PLUS 6000VA NO BATT:97%
  • Rack capacity
    • UPS DAKER DK PLUS 10000VA NO BATT:3U
    • UPS DAKER DK PLUS 6000VA NO BATT:2U
  • Width
    • UPS DAKER DK PLUS 10000VA NO BATT:132 mm
    • UPS DAKER DK PLUS 6000VA NO BATT:88 mm
  • Weight
    • UPS DAKER DK PLUS 10000VA NO BATT:26 kg
    • UPS DAKER DK PLUS 6000VA NO BATT:25 kg
  • Package width
    • UPS DAKER DK PLUS 10000VA NO BATT:132 mm
    • UPS DAKER DK PLUS 6000VA NO BATT:88 mm
  • Package depth
    • UPS DAKER DK PLUS 10000VA NO BATT:39.5 mm
    • UPS DAKER DK PLUS 6000VA NO BATT:26.3 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of UPS DAKER DK PLUS 10000VA NO BATT, UPS DAKER DK PLUS 6000VA NO BATT
62 specifications
Features3 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers10 kVA6 kVA
Output powerDiffers10000 W6000 W
WaveformSineSine
Input operation voltage (min)176 V176 V
Input operation voltage (max)280 V280 V
Input frequency47/63 Hz47/63 Hz
Output operation voltage (min)228 V228 V
Output operation voltage (max)232 V232 V
Output frequency50/60 Hz50/60 Hz
Output voltage regulation1%1%
Surge energy ratingKnown for oneUnknown — not stated by the source1900 J
Number of input phases11
Number of output phases11
Efficiency94%94%
Efficiency (ECO mode)Differs98%97%
Power factor11
Input power factor0.990.99
Output power factor11
Crest factor3:13:1
Emergency Power Off (EPO)YesYes
Output voltage Total Harmonic Distortion (THD)3%3%
Input current Total Harmonic Distortion (THD)3%3%
Noise level50 dB50 dB
Management protocolsNetwork management,Simple Network Management Protocol (SNMP)Network management,Simple Network Management Protocol (SNMP)
Potential-free outputNoNo
Auto shut-offNoNo
Detachable power cordYesYes
Power source typeACAC
Ports & interfacesidentical
AC outlet typesHardwireHardwire
Power plugHardwireHardwire
AC outlets quantity1 AC outlet(s)1 AC outlet(s)
USB portYesYes
Serial interfaceYesYes
Serial interface typeRS-232RS-232
Design1 differ
Form factorRackmountRackmount
Product colourBlackBlack
Rack capacityDiffers3U2U
Display typeLCDLCD
LED indicatorsStatusStatus
International Protection (IP) codeIP20IP20
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)0 - 95%0 - 95%
Certificatesidentical
CertificationEN 62040-1, EN 62040-2, EN 62040-3EN 62040-1, EN 62040-2, EN 62040-3
Weight & dimensions2 differ
WidthDiffers132 mm88 mm
Depth680 mm680 mm
Height440 mm440 mm
WeightDiffers26 kg25 kg
Packaging data3 differ
Package widthDiffers132 mm88 mm
Package depthDiffers39.5 mm26.3 mm
Package height440 mm440 mm
Package weightDiffers21.7 kg18.8 kg
Logistics data7 differ
Products per palletDiffers10 pc(s)6 pc(s)
Pallet net heightDiffers149.5 cm83 cm
Pallet net length100 cm100 cm
Pallet net weightDiffers228 kg118.8 kg
Pallet net width120 cm120 cm
Master (outer) case widthDiffers560 mm565 mm
Master (outer) case lengthDiffers909 mm860 mm
Master (outer) case heightDiffers272 mm220 mm
Master (outer) case gross weightDiffers22.8 kg19.8 kg
Products per master (outer) case1 pc(s)1 pc(s)

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons