Product comparison · 2 uninterruptible power supplies (upss)

Legrand TRIMOD HE 15kVA/kW 400V 22min vs Legrand Whad HE 1000

Add a product
  • 26specifications compared
  • 18differ
  • 8identical
  • 48known for one product only

Key differences

The Legrand TRIMOD HE 15kVA/kW 400V 22min has 14 kVA more output power capacity than the Legrand Whad HE 1000 (15 kVA vs 1 kVA). The Legrand TRIMOD HE 15kVA/kW 400V 22min has 14,000 W more output power than the Legrand Whad HE 1000 (15000 W vs 1000 W). The Legrand TRIMOD HE 15kVA/kW 400V 22min has 196 V more input operation voltage (min) than the Legrand Whad HE 1000 (380 V vs 184 V). Waveform: Pure sine on the Legrand TRIMOD HE 15kVA/kW 400V 22min, Sine on the Legrand Whad HE 1000. Input frequency: 45/65 Hz on the Legrand TRIMOD HE 15kVA/kW 400V 22min, 50/60 Hz on the Legrand Whad HE 1000.

  • Output power capacity
    • TRIMOD HE 15kVA/kW 400V 22min:15 kVA
    • Whad HE 1000:1 kVA
  • Output power
    • TRIMOD HE 15kVA/kW 400V 22min:15000 W
    • Whad HE 1000:1000 W
  • Waveform
    • TRIMOD HE 15kVA/kW 400V 22min:Pure sine
    • Whad HE 1000:Sine
  • Input operation voltage (min)
    • TRIMOD HE 15kVA/kW 400V 22min:380 V
    • Whad HE 1000:184 V
  • Input operation voltage (max)
    • TRIMOD HE 15kVA/kW 400V 22min:415 V
    • Whad HE 1000:264 V
  • Input frequency
    • TRIMOD HE 15kVA/kW 400V 22min:45/65 Hz
    • Whad HE 1000:50/60 Hz
  • Output operation voltage (max)
    • TRIMOD HE 15kVA/kW 400V 22min:415 V
    • Whad HE 1000:230 V
  • Efficiency
    • TRIMOD HE 15kVA/kW 400V 22min:96%
    • Whad HE 1000:93.5%

Side by side

Differences highlightedShow differences only (on)
Comparison of TRIMOD HE 15kVA/kW 400V 22min, Whad HE 1000
74 specifications
Features11 differ
Output power capacityDiffers15 kVA1 kVA
Output powerDiffers15000 W1000 W
WaveformDiffersPure sineSine
Input operation voltage (min)Differs380 V184 V
Input operation voltage (max)Differs415 V264 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Known for one380 VUnknown — not stated by the source
Output operation voltage (max)Differs415 V230 V
Output frequency regulationKnown for one-2 - 2 HzUnknown — not stated by the source
Output voltage regulationKnown for one-1 - 1%Unknown — not stated by the source
Maximum currentKnown for one86.4 AUnknown — not stated by the source
Number of input phasesKnown for one3Unknown — not stated by the source
Number of output phasesKnown for one3Unknown — not stated by the source
EfficiencyDiffers96%93.5%
Efficiency (ECO mode)Known for one99%Unknown — not stated by the source
Input power factorKnown for one1Unknown — not stated by the source
Crest factorDiffers3:13.5:1
ECO modeKnown for oneYesUnknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one2%Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Differs3%10%
Noise levelDiffers62 dB42 dB
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Management protocolsKnown for oneNetwork management,Simple Network Management Protocol (SNMP)Unknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Power source typeKnown for oneACUnknown — not stated by the source
Power factorKnown for oneUnknown — not stated by the source0.99
Total Harmonic Distortion (THD) (linear load)Known for oneUnknown — not stated by the source1%
Total Harmonic Distortion (THD) (non-linear load)Known for oneUnknown — not stated by the source4%
Ports & interfaces1 differ
Serial interfaceKnown for oneYesUnknown — not stated by the source
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
RS-232 portsDiffers21
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
AC outlet typesKnown for oneUnknown — not stated by the sourceC13 coupler
Batteryidentical
Typical backup time at full loadKnown for one0.48333333333333 minUnknown — not stated by the source
Charging currentKnown for one2.5 AUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Cold startKnown for oneYesUnknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source5 Ah
Number of batteries supportedKnown for oneUnknown — not stated by the source3
Design1 differ
Form factorDiffersTowerCompact
ModularKnown for oneYesUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditions1 differ
Operating relative humidity (H-H)Differs0 - 95%20 - 80%
Operating altitudeKnown for one0 - 1000 mUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneCE, EAC, CMIM, EN 62040-1, EN 62040-2, EN 62040-3Unknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers414 mm160 mm
DepthDiffers628 mm402 mm
HeightDiffers1650 mm319 mm
WeightDiffers350 kg12 kg
Packaging dataidentical
Package widthKnown for one414 mmUnknown — not stated by the source
Package depthKnown for one429 mmUnknown — not stated by the source
Package heightKnown for one1650 mmUnknown — not stated by the source
Package weightKnown for one354.5 kgUnknown — not stated by the source
Logistics dataidentical
Products per palletKnown for one1 pc(s)Unknown — not stated by the source
Pallet net heightKnown for one2.22 mUnknown — not stated by the source
Pallet net lengthKnown for one130 cmUnknown — not stated by the source
Pallet net weightKnown for one373.2 kgUnknown — not stated by the source
Pallet net widthKnown for one145 cmUnknown — not stated by the source
Master (outer) case widthKnown for one800 mmUnknown — not stated by the source
Master (outer) case lengthKnown for one1200 mmUnknown — not stated by the source
Master (outer) case heightKnown for one2105 mmUnknown — not stated by the source
Master (outer) case gross weightKnown for one373.2 kgUnknown — not stated by the source
Products per master (outer) caseKnown for one1 pc(s)Unknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceEN 62040-1, EN 62040-2, EN 62040-3

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons