Product comparison · 2 uninterruptible power supplies (upss)

Legrand Onduleur Keor multiplug avec multiprise de sortie - 600 VA vs Legrand TRIMOD HE 10kVA/kW 400V 27min

Add a product
  • 36specifications compared
  • 29differ
  • 7identical
  • 29known for one product only

Key differences

The Legrand TRIMOD HE 10kVA/kW 400V 27min has 9.4 kVA more output power capacity than the Legrand Onduleur Keor multiplug avec multiprise de sortie - 600 VA (10 kVA vs 0.6 kVA). The Legrand TRIMOD HE 10kVA/kW 400V 27min has 9,640 W more output power than the Legrand Onduleur Keor multiplug avec multiprise de sortie - 600 VA (10000 W vs 360 W). The Legrand TRIMOD HE 10kVA/kW 400V 27min has 200 V more input operation voltage (min) than the Legrand Onduleur Keor multiplug avec multiprise de sortie - 600 VA (380 V vs 180 V). UPS topology: Standby (Offline) on the Legrand Onduleur Keor multiplug avec multiprise de sortie - 600 VA, Double-conversion (Online) on the Legrand TRIMOD HE 10kVA/kW 400V 27min. Input frequency: 47/63 Hz on the Legrand Onduleur Keor multiplug avec multiprise de sortie - 600 VA, 45/65 Hz on the Legrand TRIMOD HE 10kVA/kW 400V 27min.

  • UPS topology
    • Onduleur Keor multiplug avec multiprise de sortie - 600 VA:Standby (Offline)
    • TRIMOD HE 10kVA/kW 400V 27min:Double-conversion (Online)
  • Output power capacity
    • Onduleur Keor multiplug avec multiprise de sortie - 600 VA:0.6 kVA
    • TRIMOD HE 10kVA/kW 400V 27min:10 kVA
  • Output power
    • Onduleur Keor multiplug avec multiprise de sortie - 600 VA:360 W
    • TRIMOD HE 10kVA/kW 400V 27min:10000 W
  • Input operation voltage (min)
    • Onduleur Keor multiplug avec multiprise de sortie - 600 VA:180 V
    • TRIMOD HE 10kVA/kW 400V 27min:380 V
  • Input operation voltage (max)
    • Onduleur Keor multiplug avec multiprise de sortie - 600 VA:270 V
    • TRIMOD HE 10kVA/kW 400V 27min:415 V
  • Input frequency
    • Onduleur Keor multiplug avec multiprise de sortie - 600 VA:47/63 Hz
    • TRIMOD HE 10kVA/kW 400V 27min:45/65 Hz
  • Output operation voltage (min)
    • Onduleur Keor multiplug avec multiprise de sortie - 600 VA:207 V
    • TRIMOD HE 10kVA/kW 400V 27min:380 V
  • Output operation voltage (max)
    • Onduleur Keor multiplug avec multiprise de sortie - 600 VA:253 V
    • TRIMOD HE 10kVA/kW 400V 27min:415 V

Side by side

Differences highlightedShow differences only (off)
Comparison of Onduleur Keor multiplug avec multiprise de sortie - 600 VA, TRIMOD HE 10kVA/kW 400V 27min
65 specifications
Features10 differ
UPS topologyDiffersStandby (Offline)Double-conversion (Online)
Output power capacityDiffers0.6 kVA10 kVA
Output powerDiffers360 W10000 W
WaveformKnown for oneUnknown — not stated by the sourceSine
Input operation voltage (min)Differs180 V380 V
Input operation voltage (max)Differs270 V415 V
Input frequencyDiffers47/63 Hz45/65 Hz
Output operation voltage (min)Differs207 V380 V
Output operation voltage (max)Differs253 V415 V
Output frequency50/60 Hz50/60 Hz
Number of input phasesDiffers13
Number of output phasesDiffers13
EfficiencyKnown for oneUnknown — not stated by the source96%
Efficiency (ECO mode)Known for oneUnknown — not stated by the source99%
Power factorKnown for oneUnknown — not stated by the source1
Crest factorKnown for oneUnknown — not stated by the source3:1
ECO modeKnown for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source2%
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Management protocolsKnown for oneUnknown — not stated by the sourceNetwork management,Simple Network Management Protocol (SNMP)
Power source typeACAC
Power protection featuresKnown for oneOvercharge, Overdischarge, Overheating, Short circuitUnknown — not stated by the source
Potential-free outputKnown for oneNoUnknown — not stated by the source
Auto-restartKnown for oneYesUnknown — not stated by the source
Detachable power cordKnown for oneYesUnknown — not stated by the source
Ports & interfacesidentical
RS-232 portsKnown for oneUnknown — not stated by the source2
AC outlet typesKnown for oneType EUnknown — not stated by the source
AC outlets quantityKnown for one6 AC outlet(s)Unknown — not stated by the source
Number of type F outputsKnown for one6Unknown — not stated by the source
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Battery1 differ
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Battery voltage12 V12 V
Typical backup time at full loadDiffers10 min0.58333333333333 min
Cold startKnown for oneUnknown — not stated by the sourceYes
Battery capacityKnown for one7 AhUnknown — not stated by the source
Number of batteries supportedKnown for one1Unknown — not stated by the source
Design2 differ
Form factorDiffersCompactTower
Product colourDiffersBlack, WhiteBlack
Display typeKnown for oneUnknown — not stated by the sourceLED
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP21
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 50 °C
Operating relative humidity (H-H)Differs0 - 90%20 - 95%
Weight & dimensions4 differ
WidthDiffers250 mm414 mm
DepthDiffers97.5 mm628 mm
HeightDiffers229 mm1370 mm
WeightDiffers4 kg279 kg
Packaging data4 differ
Package widthDiffers250 mm414 mm
Package depthDiffers5.58 mm356.2 mm
Package heightDiffers229 mm1370 mm
Package weightDiffers3.88 kg279.8 kg
Logistics data7 differ
Products per palletDiffers48 pc(s)1 pc(s)
Pallet net height175 cm175 cm
Pallet net length100 cm100 cm
Pallet net weightDiffers211.3 kg294.5 kg
Pallet net width120 cm120 cm
Master (outer) case widthDiffers306 mm800 mm
Master (outer) case lengthDiffers332 mm1200 mm
Master (outer) case heightDiffers345 mm1610 mm
Master (outer) case gross weightDiffers8.8 kg294.5 kg
Products per master (outer) caseDiffers2 pc(s)1 pc(s)
Certificatesidentical
CertificationKnown for oneEN62040-1, EN62040-2Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.