Product comparison · 2 uninterruptible power supplies (upss)

Legrand Keor T20 vs Legrand Niky 600 VA 300 W

Add a product
  • 17specifications compared
  • 14differ
  • 3identical
  • 21known for one product only

Key differences

The Legrand Keor T20 has 19.4 kVA more output power capacity than the Legrand Niky 600 VA 300 W (20 kVA vs 0.6 kVA). The Legrand Keor T20 has 17,700 W more output power than the Legrand Niky 600 VA 300 W (18000 W vs 300 W). The Legrand Keor T20 has 48 V more input operation voltage (min) than the Legrand Niky 600 VA 300 W (208 V vs 160 V). UPS topology: Double-conversion (Online) on the Legrand Keor T20, Line-Interactive on the Legrand Niky 600 VA 300 W. Input frequency: 45/65 Hz on the Legrand Keor T20, 50/60 Hz on the Legrand Niky 600 VA 300 W.

  • UPS topology
    • Keor T20:Double-conversion (Online)
    • Niky 600 VA 300 W:Line-Interactive
  • Output power capacity
    • Keor T20:20 kVA
    • Niky 600 VA 300 W:0.6 kVA
  • Output power
    • Keor T20:18000 W
    • Niky 600 VA 300 W:300 W
  • Input operation voltage (min)
    • Keor T20:208 V
    • Niky 600 VA 300 W:160 V
  • Input operation voltage (max)
    • Keor T20:467 V
    • Niky 600 VA 300 W:290 V
  • Input frequency
    • Keor T20:45/65 Hz
    • Niky 600 VA 300 W:50/60 Hz
  • Output operation voltage (min)
    • Keor T20:380 V
    • Niky 600 VA 300 W:207 V
  • Output operation voltage (max)
    • Keor T20:415 V
    • Niky 600 VA 300 W:253 V

Side by side

Differences highlightedShow differences only (on)
Comparison of Keor T20, Niky 600 VA 300 W
38 specifications
Features9 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers20 kVA0.6 kVA
Output powerDiffers18000 W300 W
Input operation voltage (min)Differs208 V160 V
Input operation voltage (max)Differs467 V290 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Differs380 V207 V
Output operation voltage (max)Differs415 V253 V
Output voltage Total Harmonic Distortion (THD)Differs2%3%
Noise levelKnown for oneUnknown — not stated by the source40 dB
EfficiencyKnown for one96%Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Output power factorKnown for one0.9Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Ports & interfacesidentical
AC outlet typesKnown for oneUnknown — not stated by the sourceType F
AC outlets quantityKnown for oneUnknown — not stated by the source1 AC outlet(s)
Number of type F outputsKnown for oneUnknown — not stated by the source1
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
RS-232 portsKnown for one1Unknown — not stated by the source
Batteryidentical
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of batteries supportedKnown for oneUnknown — not stated by the source1
Typical backup time at full loadKnown for oneUnknown — not stated by the source5 min
Typical backup time at half loadKnown for oneUnknown — not stated by the source30 min
Designidentical
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Display typeKnown for oneLCDUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP20Unknown — not stated by the source
Operational conditions1 differ
Operating relative humidity (H-H)Differs20 - 95%0 - 95%
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceEN 62040-1, EN 62040-2, EN 62040-3
Weight & dimensions4 differ
WidthDiffers400 mm95 mm
DepthDiffers800 mm349 mm
HeightDiffers1650 mm171 mm
WeightDiffers286 kg7 kg
Other featuresidentical
Battery typeKnown for oneVRLA-AGMUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.