Product comparison · 2 uninterruptible power supplies (upss)

Legrand Keor LP 3kVA vs Nilox 17NXGCLI38002 uninterruptible power supply (UPS) 1.9 kVA

Add a product
  • 29specifications compared
  • 21differ
  • 8identical
  • 24known for one product only

Key differences

  • Output power capacity
    • Keor LP 3kVA:3 kVA
    • 17NXGCLI38002 uninterruptible power supply (UPS) 1.9 kVA:1.9 kVA
  • Output power
    • Keor LP 3kVA:2700 W
    • 17NXGCLI38002 uninterruptible power supply (UPS) 1.9 kVA:900 W
  • Input operation voltage (max)
    • Keor LP 3kVA:300 V
    • 17NXGCLI38002 uninterruptible power supply (UPS) 1.9 kVA:160 V
  • Input frequency
    • Keor LP 3kVA:45/65 Hz
    • 17NXGCLI38002 uninterruptible power supply (UPS) 1.9 kVA:50/60 Hz
  • Output operation voltage (min)
    • Keor LP 3kVA:230 V
    • 17NXGCLI38002 uninterruptible power supply (UPS) 1.9 kVA:220 V
  • Output operation voltage (max)
    • Keor LP 3kVA:230 V
    • 17NXGCLI38002 uninterruptible power supply (UPS) 1.9 kVA:240 V
  • Efficiency
    • Keor LP 3kVA:90%
    • 17NXGCLI38002 uninterruptible power supply (UPS) 1.9 kVA:93%
  • AC outlet types
    • Keor LP 3kVA:C13 coupler
    • 17NXGCLI38002 uninterruptible power supply (UPS) 1.9 kVA:IEC 320

Side by side

Differences highlightedShow differences only (on)
Comparison of Keor LP 3kVA, 17NXGCLI38002
53 specifications
Features7 differ
UPS topologyKnown for oneDouble-conversion (Online)Unknown — not stated by the source
Output power capacityDiffers3 kVA1.9 kVA
Output powerDiffers2700 W900 W
WaveformKnown for oneSineUnknown — not stated by the source
Input operation voltage (max)Differs300 V160 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Differs230 V220 V
Output operation voltage (max)Differs230 V240 V
Output voltage regulationKnown for one1%Unknown — not stated by the source
Number of input phasesKnown for one1Unknown — not stated by the source
EfficiencyDiffers90%93%
Power factorKnown for one0.98Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Web-based managementKnown for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Fault, Low battery alarm, Overload alarmUnknown — not stated by the source
Management protocolsKnown for oneSNMPUnknown — not stated by the source
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Surge energy ratingKnown for oneUnknown — not stated by the source0 J
Ports & interfaces3 differ
AC outlet typesDiffersC13 couplerIEC 320
Power plugDiffersC20 couplerC14 coupler
AC outlets quantityDiffers6 AC outlet(s)5 AC outlet(s)
Serial interfaceKnown for oneYesUnknown — not stated by the source
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
USB portKnown for oneUnknown — not stated by the sourceYes
Battery5 differ
Battery capacityDiffers7 Ah9 Ah
Battery voltageDiffers72 V12 V
Number of batteries supportedDiffers62
Typical backup time at half loadDiffers7 min3 min
Battery recharge timeDiffers3 h7 h
Automatic battery testKnown for oneYesUnknown — not stated by the source
Typical backup time at full loadKnown for oneUnknown — not stated by the source10 min
Designidentical
International Protection (IP) codeKnown for oneIP21Unknown — not stated by the source
Form factorKnown for oneUnknown — not stated by the sourceTower
Operational conditions1 differ
Operating relative humidity (H-H)Differs20 - 80%0 - 85%
Certificates1 differ
CertificationDiffersCE, EN 62040-1, EN 62040-2CE
Weight & dimensions4 differ
WidthDiffers322 mm148 mm
DepthDiffers151 mm315 mm
HeightDiffers444 mm198 mm
WeightDiffers23 kg11.5 kg
Other featuresidentical
Output voltageKnown for oneUnknown — not stated by the source220 V