Key differences

  • Output power capacity
    • Keor LP 3kVA:3 kVA
    • 17NXGCLI18003 uninterruptible power supply (UPS) 1.2 kVA:1.2 kVA
  • Output power
    • Keor LP 3kVA:2700 W
    • 17NXGCLI18003 uninterruptible power supply (UPS) 1.2 kVA:600 W
  • Input operation voltage (min)
    • Keor LP 3kVA:160 V
    • 17NXGCLI18003 uninterruptible power supply (UPS) 1.2 kVA:220 V
  • Input operation voltage (max)
    • Keor LP 3kVA:300 V
    • 17NXGCLI18003 uninterruptible power supply (UPS) 1.2 kVA:240 V
  • Input frequency
    • Keor LP 3kVA:45/65 Hz
    • 17NXGCLI18003 uninterruptible power supply (UPS) 1.2 kVA:50/60 Hz
  • Output operation voltage (min)
    • Keor LP 3kVA:230 V
    • 17NXGCLI18003 uninterruptible power supply (UPS) 1.2 kVA:220 V
  • Output operation voltage (max)
    • Keor LP 3kVA:230 V
    • 17NXGCLI18003 uninterruptible power supply (UPS) 1.2 kVA:240 V
  • Efficiency
    • Keor LP 3kVA:90%
    • 17NXGCLI18003 uninterruptible power supply (UPS) 1.2 kVA:93%

Side by side

Differences highlightedShow differences only (on)
Comparison of Keor LP 3kVA, 17NXGCLI18003
56 specifications
Features8 differ
UPS topologyKnown for oneDouble-conversion (Online)Unknown — not stated by the source
Output power capacityDiffers3 kVA1.2 kVA
Output powerDiffers2700 W600 W
Input operation voltage (min)Differs160 V220 V
Input operation voltage (max)Differs300 V240 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Differs230 V220 V
Output operation voltage (max)Differs230 V240 V
Output voltage regulationKnown for one1%Unknown — not stated by the source
Number of input phasesKnown for one1Unknown — not stated by the source
EfficiencyDiffers90%93%
Power factorKnown for one0.98Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Web-based managementKnown for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Fault, Low battery alarm, Overload alarmUnknown — not stated by the source
Management protocolsKnown for oneSNMPUnknown — not stated by the source
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Surge energy ratingKnown for oneUnknown — not stated by the source0 J
Response timeKnown for oneUnknown — not stated by the source4 ms
Ports & interfacesidentical
AC outlet typesKnown for oneC13 couplerUnknown — not stated by the source
Power plugKnown for oneC20 couplerUnknown — not stated by the source
AC outlets quantityKnown for one6 AC outlet(s)Unknown — not stated by the source
Serial interfaceKnown for oneYesUnknown — not stated by the source
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
Number of output IEC jumpersKnown for oneUnknown — not stated by the source320
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Battery4 differ
Battery voltageDiffers72 V12 V
Number of batteries supportedDiffers62
Typical backup time at half loadDiffers7 min5 min
Battery recharge timeDiffers3 h7 h
Automatic battery testKnown for oneYesUnknown — not stated by the source
Typical backup time at full loadKnown for oneUnknown — not stated by the source10 min
Designidentical
LED indicatorsKnown for oneYesUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP21Unknown — not stated by the source
Form factorKnown for oneUnknown — not stated by the sourceTower
Display typeKnown for oneUnknown — not stated by the sourceLED
Operational conditions1 differ
Operating relative humidity (H-H)Differs20 - 80%0 - 85%
Certificates1 differ
CertificationDiffersCE, EN 62040-1, EN 62040-2CE, VDE, GOST, C-tick
Weight & dimensions4 differ
WidthDiffers322 mm148 mm
DepthDiffers151 mm315 mm
HeightDiffers444 mm198 mm
WeightDiffers23 kg10.5 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.