Product comparison · 2 uninterruptible power supplies (upss)

Legrand Keor LP 1kVA FR vs Legrand Keor LP 2kVA FR

Add a product
  • 47specifications compared
  • 11differ
  • 36identical
  • 3known for one product only

Key differences

  • Output power capacity
    • Keor LP 1kVA FR:1 kVA
    • Keor LP 2kVA FR:2 kVA
  • Output power
    • Keor LP 1kVA FR:900 W
    • Keor LP 2kVA FR:1800 W
  • AC outlets quantity
    • Keor LP 1kVA FR:4 AC outlet(s)
    • Keor LP 2kVA FR:5 AC outlet(s)
  • Number of type F outputs
    • Keor LP 1kVA FR:1
    • Keor LP 2kVA FR:2
  • Battery voltage
    • Keor LP 1kVA FR:24 V
    • Keor LP 2kVA FR:48 V
  • Number of batteries supported
    • Keor LP 1kVA FR:2
    • Keor LP 2kVA FR:4
  • Typical backup time at half load
    • Keor LP 1kVA FR:6 min
    • Keor LP 2kVA FR:5 min
  • Width
    • Keor LP 1kVA FR:236 mm
    • Keor LP 2kVA FR:322 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of Keor LP 1kVA FR, Keor LP 2kVA FR
50 specifications
Features2 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers1 kVA2 kVA
Output powerDiffers900 W1800 W
WaveformSineSine
Input operation voltage (min)160 V160 V
Input operation voltage (max)300 V300 V
Input frequency45/65 Hz45/65 Hz
Output operation voltage (min)230 V230 V
Output operation voltage (max)230 V230 V
Output voltage regulation1%1%
Number of input phases11
Efficiency90%90%
Power factor0.980.98
Input power factor0.990.99
Crest factor3:13:1
Emergency Power Off (EPO)YesYes
Overload capacity (10 seconds)Known for oneUnknown — not stated by the source150%
Output voltage Total Harmonic Distortion (THD)3%3%
Noise level50 dB50 dB
Audible alarm(s)YesYes
Web-based managementYesYes
Audible alarm modesAlarm when on battery, Fault, Low battery alarm, Overload alarmAlarm when on battery, Fault, Low battery alarm, Overload alarm
Management protocolsSNMPSNMP
Socket circuit breakerKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlet typesC13 couplerC13 coupler
Power plugC14 couplerC14 coupler
AC outlets quantityDiffers4 AC outlet(s)5 AC outlet(s)
Number of type F outputsDiffers12
Serial interfaceYesYes
Serial interface typeRS-232RS-232
RS-232 ports11
Emergency Power Off (EPO) connectorYesYes
Battery3 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery capacity7 Ah7 Ah
Battery voltageDiffers24 V48 V
Number of batteries supportedDiffers24
Typical backup time at half loadDiffers6 min5 min
Battery recharge time3 h3 h
Automatic battery testYesYes
Designidentical
Product colourBlackBlack
LED indicatorsYesYes
International Protection (IP) codeIP21IP21
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)20 - 80%20 - 80%
Certificatesidentical
CertificationCE, EN 62040-1, EN 62040-2CE, EN 62040-1, EN 62040-2
Weight & dimensions4 differ
WidthDiffers236 mm322 mm
DepthDiffers144 mm151 mm
HeightDiffers367 mm444 mm
WeightDiffers10 kg17 kg
Other featuresidentical