Product comparison · 2 uninterruptible power supplies (upss)

Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA vs Vertiv Liebert ITON CX 600VA

Add a product
  • 13specifications compared
  • 12differ
  • 1identical
  • 28known for one product only

Key differences

The Vertiv Liebert ITON CX 600VA has 598 kVA more output power capacity than the Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA (600 kVA vs 2 kVA). The Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA has 1,640 W more output power than the Vertiv Liebert ITON CX 600VA (2000 W vs 360 W). The Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA has 10 V more input operation voltage (min) than the Vertiv Liebert ITON CX 600VA (230 V vs 220 V). UPS topology: Double-conversion (Online) on the Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA, Line-Interactive on the Vertiv Liebert ITON CX 600VA. Waveform: Sine on the Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA, Simulated sine on the Vertiv Liebert ITON CX 600VA.

  • UPS topology
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:Double-conversion (Online)
    • Liebert ITON CX 600VA:Line-Interactive
  • Output power capacity
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:2 kVA
    • Liebert ITON CX 600VA:600 kVA
  • Output power
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:2000 W
    • Liebert ITON CX 600VA:360 W
  • Waveform
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:Sine
    • Liebert ITON CX 600VA:Simulated sine
  • Input operation voltage (min)
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:230 V
    • Liebert ITON CX 600VA:220 V
  • Input frequency
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:50/60 Hz
    • Liebert ITON CX 600VA:50 Hz
  • Form factor
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:Rackmount/Tower
    • Liebert ITON CX 600VA:Tower
  • Product colour
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:White, Black
    • Liebert ITON CX 600VA:Black

Side by side

Differences highlightedShow differences only (off)
Comparison of Keor-DK-2000-B, Liebert ITON CX 600VA
41 specifications
Features6 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers2 kVA600 kVA
Output powerDiffers2000 W360 W
WaveformDiffersSineSimulated sine
Input operation voltage (min)Differs230 V220 V
Input operation voltage (max)230 V230 V
Input frequencyDiffers50/60 Hz50 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source140 V
Output operation voltage (max)Known for oneUnknown — not stated by the source300 V
Output frequencyKnown for oneUnknown — not stated by the source50 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Response timeKnown for oneUnknown — not stated by the source4 ms
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Noise levelKnown for oneUnknown — not stated by the source40 dB
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Ports & interfacesidentical
USB portKnown for oneUnknown — not stated by the sourceYes
USB port typeKnown for oneUnknown — not stated by the sourceUSB Type-B
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Serial interface typeKnown for oneUnknown — not stated by the sourceRS-232
RS-232 portsKnown for oneUnknown — not stated by the source1
AC outlets quantityKnown for one7 AC outlet(s)Unknown — not stated by the source
Batteryidentical
Battery capacityKnown for oneUnknown — not stated by the source7 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of battery cellsKnown for oneUnknown — not stated by the source1
Battery recharge timeKnown for oneUnknown — not stated by the source8 h
Cold startKnown for oneUnknown — not stated by the sourceYes
Design2 differ
Form factorDiffersRackmount/TowerTower
Product colourDiffersWhite, BlackBlack
LED indicatorsKnown for oneUnknown — not stated by the sourceFault, Power
Backlight colourKnown for oneUnknown — not stated by the sourceRed/Green
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 40 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-15 - 50 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes
Weight & dimensions4 differ
WidthDiffers440 mm101 mm
DepthDiffers640 mm279 mm
HeightDiffers88 mm142 mm
WeightDiffers24 kg4.2 kg
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceIndia

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons