Product comparison · 2 uninterruptible power supplies (upss)

Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA vs Vertiv Liebert GXT MT CX

Add a product
  • 13specifications compared
  • 12differ
  • 1identical
  • 29known for one product only

Key differences

The Vertiv Liebert GXT MT CX has 1 kVA more output power capacity than the Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA (3 kVA vs 2 kVA). The Vertiv Liebert GXT MT CX has 400 W more output power than the Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA (2400 W vs 2000 W). The Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA has 120 V more input operation voltage (min) than the Vertiv Liebert GXT MT CX (230 V vs 110 V). Waveform: Sine on the Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA, Sine/Pure sine on the Vertiv Liebert GXT MT CX. Input frequency: 50/60 Hz on the Legrand Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA, 40 - 70 Hz on the Vertiv Liebert GXT MT CX.

  • Output power capacity
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:2 kVA
    • Liebert GXT MT CX:3 kVA
  • Output power
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:2000 W
    • Liebert GXT MT CX:2400 W
  • Waveform
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:Sine
    • Liebert GXT MT CX:Sine/Pure sine
  • Input operation voltage (min)
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:230 V
    • Liebert GXT MT CX:110 V
  • Input operation voltage (max)
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:230 V
    • Liebert GXT MT CX:280 V
  • Input frequency
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:50/60 Hz
    • Liebert GXT MT CX:40 - 70 Hz
  • Form factor
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:Rackmount/Tower
    • Liebert GXT MT CX:Tower
  • Product colour
    • Keor -DK-2000-B uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:White, Black
    • Liebert GXT MT CX:Black

Side by side

Differences highlightedShow differences only (off)
Comparison of Keor-DK-2000-B, Liebert GXT MT CX
42 specifications
Features6 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers2 kVA3 kVA
Output powerDiffers2000 W2400 W
WaveformDiffersSineSine/Pure sine
Input operation voltage (min)Differs230 V110 V
Input operation voltage (max)Differs230 V280 V
Input frequencyDiffers50/60 Hz40 - 70 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source200 V
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
EfficiencyKnown for oneUnknown — not stated by the source90%
Input power factorKnown for oneUnknown — not stated by the source0.99
Crest factorKnown for oneUnknown — not stated by the source3:1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
Noise levelKnown for oneUnknown — not stated by the source45 dB
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Audible alarm(s)Known for oneUnknown — not stated by the sourceYes
Audible alarm modesKnown for oneUnknown — not stated by the sourceFault, Low battery alarm
Ports & interfacesidentical
USB portKnown for oneUnknown — not stated by the sourceYes
Serial interfaceKnown for oneUnknown — not stated by the sourceYes
Serial interface typeKnown for oneUnknown — not stated by the sourceRS-232
RS-232 portsKnown for oneUnknown — not stated by the source1
AC outlets quantityKnown for one7 AC outlet(s)Unknown — not stated by the source
Batteryidentical
Number of battery cellsKnown for oneUnknown — not stated by the source6
Charging currentKnown for oneUnknown — not stated by the source16 A
Design2 differ
Form factorDiffersRackmount/TowerTower
Product colourDiffersWhite, BlackBlack
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Display typeKnown for oneUnknown — not stated by the sourceLCD
LED indicatorsKnown for oneUnknown — not stated by the sourceFault, Power
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 50 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes
Weight & dimensions4 differ
WidthDiffers440 mm145 mm
DepthDiffers640 mm397 mm
HeightDiffers88 mm333 mm
WeightDiffers24 kg9.8 kg
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceIndia

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons