Product comparison · 2 uninterruptible power supplies (upss)

Legrand ASI KEOR SPE rack 1U 750VA vs Legrand HPE 200KW

Add a product
  • 14specifications compared
  • 12differ
  • 2identical
  • 18known for one product only

Key differences

The Legrand HPE 200KW has 199.25 kVA more output power capacity than the Legrand ASI KEOR SPE rack 1U 750VA (200 kVA vs 0.75 kVA). The Legrand HPE 200KW has 199,475 W more output power than the Legrand ASI KEOR SPE rack 1U 750VA (200000 W vs 525 W). The Legrand HPE 200KW has 145 V more input operation voltage (min) than the Legrand ASI KEOR SPE rack 1U 750VA (320 V vs 175 V). Input frequency: 47/63 Hz on the Legrand ASI KEOR SPE rack 1U 750VA, 45/65 Hz on the Legrand HPE 200KW. Form factor: Rackmount on the Legrand ASI KEOR SPE rack 1U 750VA, Tower on the Legrand HPE 200KW.

  • Output power capacity
    • ASI KEOR SPE rack 1U 750VA:0.75 kVA
    • HPE 200KW:200 kVA
  • Output power
    • ASI KEOR SPE rack 1U 750VA:525 W
    • HPE 200KW:200000 W
  • Input operation voltage (min)
    • ASI KEOR SPE rack 1U 750VA:175 V
    • HPE 200KW:320 V
  • Input operation voltage (max)
    • ASI KEOR SPE rack 1U 750VA:288 V
    • HPE 200KW:480 V
  • Input frequency
    • ASI KEOR SPE rack 1U 750VA:47/63 Hz
    • HPE 200KW:45/65 Hz
  • Output operation voltage (min)
    • ASI KEOR SPE rack 1U 750VA:208 V
    • HPE 200KW:380 V
  • Output operation voltage (max)
    • ASI KEOR SPE rack 1U 750VA:240 V
    • HPE 200KW:415 V
  • Form factor
    • ASI KEOR SPE rack 1U 750VA:Rackmount
    • HPE 200KW:Tower

Side by side

Differences highlightedShow differences only (on)
Comparison of ASI KEOR SPE rack 1U 750VA, HPE 200KW
32 specifications
Features7 differ
UPS topologyKnown for oneLine-InteractiveUnknown — not stated by the source
Output power capacityDiffers0.75 kVA200 kVA
Output powerDiffers525 W200000 W
Input operation voltage (min)Differs175 V320 V
Input operation voltage (max)Differs288 V480 V
Input frequencyDiffers47/63 Hz45/65 Hz
Output operation voltage (min)Differs208 V380 V
Output operation voltage (max)Differs240 V415 V
EfficiencyKnown for one85%Unknown — not stated by the source
Efficiency (ECO mode)Known for one98%Unknown — not stated by the source
Output power factorKnown for one0.8Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Management protocolsKnown for oneNetwork management,Simple Network Management Protocol (SNMP)Unknown — not stated by the source
Potential-free outputKnown for oneYesUnknown — not stated by the source
Auto shut-offKnown for oneYesUnknown — not stated by the source
Power source typeKnown for oneACUnknown — not stated by the source
Number of input phasesKnown for oneUnknown — not stated by the source3
Number of output phasesKnown for oneUnknown — not stated by the source3
Ports & interfacesidentical
AC outlet typesKnown for oneC13 couplerUnknown — not stated by the source
Power plugKnown for oneC14 couplerUnknown — not stated by the source
AC outlets quantityKnown for one5 AC outlet(s)Unknown — not stated by the source
Serial interfaceKnown for oneNoUnknown — not stated by the source
RS-232 portsKnown for oneUnknown — not stated by the source1
Batteryidentical
Typical backup time at full loadKnown for one0.00016 minUnknown — not stated by the source
Design1 differ
Form factorDiffersRackmountTower
Product colourKnown for oneUnknown — not stated by the sourceBlack
Weight & dimensions4 differ
WidthDiffers440 mm880 mm
DepthDiffers513 mm970 mm
HeightDiffers44 mm1978 mm
WeightDiffers13.5 kg720000 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.