Product comparison · 2 uninterruptible power supplies (upss)

Legrand ASI KEOR SP 1500 GR vs Legrand Whad He 4000

Add a product
  • 22specifications compared
  • 17differ
  • 5identical
  • 49known for one product only

Key differences

The Legrand Whad He 4000 has 2.5 kVA more output power capacity than the Legrand ASI KEOR SP 1500 GR (4 kVA vs 1.5 kVA). The Legrand Whad He 4000 has 3,100 W more output power than the Legrand ASI KEOR SP 1500 GR (4000 W vs 900 W). The Legrand ASI KEOR SP 1500 GR has 60 V more input operation voltage (min) than the Legrand Whad He 4000 (170 V vs 110 V). UPS topology: Line-Interactive on the Legrand ASI KEOR SP 1500 GR, Double-conversion (Online) on the Legrand Whad He 4000. Input frequency: 45/65 Hz on the Legrand ASI KEOR SP 1500 GR, 50/60 Hz on the Legrand Whad He 4000.

  • UPS topology
    • ASI KEOR SP 1500 GR:Line-Interactive
    • Whad He 4000:Double-conversion (Online)
  • Output power capacity
    • ASI KEOR SP 1500 GR:1.5 kVA
    • Whad He 4000:4 kVA
  • Output power
    • ASI KEOR SP 1500 GR:900 W
    • Whad He 4000:4000 W
  • Input operation voltage (min)
    • ASI KEOR SP 1500 GR:170 V
    • Whad He 4000:110 V
  • Input frequency
    • ASI KEOR SP 1500 GR:45/65 Hz
    • Whad He 4000:50/60 Hz
  • Output operation voltage (max)
    • ASI KEOR SP 1500 GR:253 V
    • Whad He 4000:230 V
  • Efficiency
    • ASI KEOR SP 1500 GR:97%
    • Whad He 4000:94%
  • AC outlet types
    • ASI KEOR SP 1500 GR:C13 coupler
    • Whad He 4000:Hardwire

Side by side

Differences highlightedShow differences only (on)
Comparison of ASI KEOR SP 1500 GR, Whad He 4000
71 specifications
Features7 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers1.5 kVA4 kVA
Output powerDiffers900 W4000 W
Input operation voltage (min)Differs170 V110 V
Input operation voltage (max)Known for one280 VUnknown — not stated by the source
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Known for one207 VUnknown — not stated by the source
Output operation voltage (max)Differs253 V230 V
Output frequencyKnown for one50/60 HzUnknown — not stated by the source
Output frequency regulationKnown for one1 HzUnknown — not stated by the source
Output voltage regulationKnown for one10%Unknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Number of input phasesKnown for one1Unknown — not stated by the source
Number of output phasesKnown for one1Unknown — not stated by the source
EfficiencyDiffers97%94%
Output power factorKnown for one0.6Unknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresKnown for oneOvercharge, Overdischarge, Overload, Short circuitUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Potential-free outputKnown for oneNoUnknown — not stated by the source
Auto shut-offKnown for oneNoUnknown — not stated by the source
Power source typeKnown for oneACUnknown — not stated by the source
Power factorKnown for oneUnknown — not stated by the source0.99
Crest factorKnown for oneUnknown — not stated by the source3.5:1
Total Harmonic Distortion (THD) (linear load)Known for oneUnknown — not stated by the source1%
Total Harmonic Distortion (THD) (non-linear load)Known for oneUnknown — not stated by the source3%
Ports & interfaces1 differ
AC outlet typesDiffersC13 couplerHardwire
Power plugKnown for oneC14 couplerUnknown — not stated by the source
AC outlets quantityKnown for one4 AC outlet(s)Unknown — not stated by the source
Number of type F outputsKnown for one2Unknown — not stated by the source
USB portKnown for oneYesUnknown — not stated by the source
USB 2.0 ports quantityKnown for one2Unknown — not stated by the source
USB port typeKnown for oneUSB Type-A/USB Type-BUnknown — not stated by the source
Serial interfaceKnown for oneYesUnknown — not stated by the source
RS-232 portsKnown for oneUnknown — not stated by the source1
Battery1 differ
Number of batteries supportedDiffers212
Battery voltageKnown for oneUnknown — not stated by the source12 V
Design2 differ
Form factorDiffersMini TowerTower
Product colourDiffersBlack, WhiteBlack
LED indicatorsKnown for oneYesUnknown — not stated by the source
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP21
Operational conditions1 differ
Operating relative humidity (H-H)Differs0 - 95%20 - 80%
Storage temperature (T-T)Known for oneUnknown — not stated by the source20 - 40 °C
Certificates1 differ
Compliance certificatesKnown for oneCEUnknown — not stated by the source
CertificationDiffersEN 62040-1, EN 62040-2CE
Sustainabilityidentical
Sustainability complianceKnown for oneYesUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers148 mm268 mm
DepthDiffers380 mm613 mm
HeightDiffers173 mm482 mm
WeightDiffers10.5 kg61 kg
Packaging dataidentical
Package widthKnown for one148 mmUnknown — not stated by the source
Package depthKnown for one9.73 mmUnknown — not stated by the source
Package heightKnown for one173 mmUnknown — not stated by the source
Package weightKnown for one11.2 kgUnknown — not stated by the source
Logistics dataidentical
Products per palletKnown for one40 pc(s)Unknown — not stated by the source
Harmonized System (HS) codeKnown for one85078000Unknown — not stated by the source
Pallet net heightKnown for one123 cmUnknown — not stated by the source
Pallet net lengthKnown for one100 cmUnknown — not stated by the source
Pallet net weightKnown for one472.3 kgUnknown — not stated by the source
Pallet net widthKnown for one120 cmUnknown — not stated by the source
Master (outer) case widthKnown for one243 mmUnknown — not stated by the source
Master (outer) case lengthKnown for one465 mmUnknown — not stated by the source
Master (outer) case heightKnown for one265 mmUnknown — not stated by the source
Master (outer) case gross weightKnown for one11.8 kgUnknown — not stated by the source
Products per master (outer) caseKnown for one1 pc(s)Unknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceEN 62040-1, EN 62040-2, EN 62040-3

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons