Product comparison · 2 uninterruptible power supplies (upss)

Legrand ARCHIMOD HE 120 kVA vs Legrand Niky S 3000VA 1800W

Add a product
  • 17specifications compared
  • 13differ
  • 4identical
  • 16known for one product only

Key differences

The Legrand ARCHIMOD HE 120 kVA has 117 kVA more output power capacity than the Legrand Niky S 3000VA 1800W (120 kVA vs 3 kVA). The Legrand ARCHIMOD HE 120 kVA has 118,200 W more output power than the Legrand Niky S 3000VA 1800W (120000 W vs 1800 W). The Legrand ARCHIMOD HE 120 kVA has 220 V more input operation voltage (min) than the Legrand Niky S 3000VA 1800W (380 V vs 160 V). UPS topology: Double-conversion (Online) on the Legrand ARCHIMOD HE 120 kVA, Line-Interactive on the Legrand Niky S 3000VA 1800W. Input frequency: 45/65 Hz on the Legrand ARCHIMOD HE 120 kVA, 50/60 Hz on the Legrand Niky S 3000VA 1800W.

  • UPS topology
    • ARCHIMOD HE 120 kVA:Double-conversion (Online)
    • Niky S 3000VA 1800W:Line-Interactive
  • Output power capacity
    • ARCHIMOD HE 120 kVA:120 kVA
    • Niky S 3000VA 1800W:3 kVA
  • Output power
    • ARCHIMOD HE 120 kVA:120000 W
    • Niky S 3000VA 1800W:1800 W
  • Input operation voltage (min)
    • ARCHIMOD HE 120 kVA:380 V
    • Niky S 3000VA 1800W:160 V
  • Input operation voltage (max)
    • ARCHIMOD HE 120 kVA:415 V
    • Niky S 3000VA 1800W:290 V
  • Input frequency
    • ARCHIMOD HE 120 kVA:45/65 Hz
    • Niky S 3000VA 1800W:50/60 Hz
  • Output operation voltage (min)
    • ARCHIMOD HE 120 kVA:380 V
    • Niky S 3000VA 1800W:207 V
  • Output operation voltage (max)
    • ARCHIMOD HE 120 kVA:415 V
    • Niky S 3000VA 1800W:253 V

Side by side

Differences highlightedShow differences only (on)
Comparison of ARCHIMOD HE 120 kVA, Niky S 3000VA 1800W
33 specifications
Features8 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers120 kVA3 kVA
Output powerDiffers120000 W1800 W
Input operation voltage (min)Differs380 V160 V
Input operation voltage (max)Differs415 V290 V
Input frequencyDiffers45/65 Hz50/60 Hz
Output operation voltage (min)Differs380 V207 V
Output operation voltage (max)Differs415 V253 V
EfficiencyKnown for one96%Unknown — not stated by the source
Input power factorKnown for one0.99Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one1%Unknown — not stated by the source
Input current Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
EMI/RFI noise filteringKnown for one65 dBUnknown — not stated by the source
Noise levelKnown for oneUnknown — not stated by the source40 dB
Ports & interfaces1 differ
RS-232 portsDiffers21
AC outlet typesKnown for oneUnknown — not stated by the sourceC13 coupler
AC outlets quantityKnown for oneUnknown — not stated by the source6 AC outlet(s)
Batteryidentical
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Number of batteries supportedKnown for oneUnknown — not stated by the source4
Typical backup time at full loadKnown for oneUnknown — not stated by the source8 min
Designidentical
Form factorKnown for oneRackmount/TowerUnknown — not stated by the source
International Protection (IP) codeKnown for oneIP21Unknown — not stated by the source
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Weight & dimensions4 differ
WidthDiffers570 mm173 mm
DepthDiffers912 mm465 mm
HeightDiffers2080 mm247 mm
WeightDiffers364 kg24 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons