Product comparison · 2 uninterruptible power supplies (upss)

Legrand ARCHIMOD HE 120 kVA vs Legrand Keor T20

Add a product
  • 21specifications compared
  • 12differ
  • 9identical
  • 10known for one product only

Key differences

The Legrand ARCHIMOD HE 120 kVA has 100 kVA more output power capacity than the Legrand Keor T20 (120 kVA vs 20 kVA). The Legrand ARCHIMOD HE 120 kVA has 102,000 W more output power than the Legrand Keor T20 (120000 W vs 18000 W). The Legrand ARCHIMOD HE 120 kVA has 172 V more input operation voltage (min) than the Legrand Keor T20 (380 V vs 208 V). International Protection (IP) code: IP21 on the Legrand ARCHIMOD HE 120 kVA, IP20 on the Legrand Keor T20.

  • Output power capacity
    • ARCHIMOD HE 120 kVA:120 kVA
    • Keor T20:20 kVA
  • Output power
    • ARCHIMOD HE 120 kVA:120000 W
    • Keor T20:18000 W
  • Input operation voltage (min)
    • ARCHIMOD HE 120 kVA:380 V
    • Keor T20:208 V
  • Input operation voltage (max)
    • ARCHIMOD HE 120 kVA:415 V
    • Keor T20:467 V
  • Output voltage Total Harmonic Distortion (THD)
    • ARCHIMOD HE 120 kVA:1%
    • Keor T20:2%
  • RS-232 ports
    • ARCHIMOD HE 120 kVA:2
    • Keor T20:1
  • International Protection (IP) code
    • ARCHIMOD HE 120 kVA:IP21
    • Keor T20:IP20
  • Operating relative humidity (H-H)
    • ARCHIMOD HE 120 kVA:0 - 95%
    • Keor T20:20 - 95%

Side by side

Differences highlightedShow differences only (off)
Comparison of ARCHIMOD HE 120 kVA, Keor T20
31 specifications
Features5 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers120 kVA20 kVA
Output powerDiffers120000 W18000 W
Input operation voltage (min)Differs380 V208 V
Input operation voltage (max)Differs415 V467 V
Input frequency45/65 Hz45/65 Hz
Output operation voltage (min)380 V380 V
Output operation voltage (max)415 V415 V
Efficiency96%96%
Input power factor0.990.99
Output power factorKnown for oneUnknown — not stated by the source0.9
Crest factorKnown for oneUnknown — not stated by the source3:1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Differs1%2%
Input current Total Harmonic Distortion (THD)3%3%
EMI/RFI noise filteringKnown for one65 dBUnknown — not stated by the source
Ports & interfaces1 differ
RS-232 portsDiffers21
Batteryidentical
Battery capacityKnown for oneUnknown — not stated by the source7 Ah
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Design1 differ
Product colourBlackBlack
Display typeKnown for oneUnknown — not stated by the sourceLCD
International Protection (IP) codeDiffersIP21IP20
Form factorKnown for oneRackmount/TowerUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)Differs0 - 95%20 - 95%
Weight & dimensions4 differ
WidthDiffers570 mm400 mm
DepthDiffers912 mm800 mm
HeightDiffers2080 mm1650 mm
WeightDiffers364 kg286 kg
Other featuresidentical
Battery typeKnown for oneUnknown — not stated by the sourceVRLA-AGM
Certificatesidentical
CertificationKnown for oneEN 62040-1, EN 62040-2, EN 62040-3Unknown — not stated by the source