Key differences

  • Output power capacity
    • 2000VA 1800W UPS:2 kVA
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:6 kVA
  • Output power
    • 2000VA 1800W UPS:1800 W
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:4800 W
  • Input operation voltage (min)
    • 2000VA 1800W UPS:220 V
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:120 V
  • Input operation voltage (max)
    • 2000VA 1800W UPS:240 V
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:208 V
  • Input frequency
    • 2000VA 1800W UPS:50/60 Hz
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:40/70 Hz
  • AC outlet types
    • 2000VA 1800W UPS:C13 coupler
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:Terminal
  • Number of batteries supported
    • 2000VA 1800W UPS:4
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:6
  • Operating relative humidity (H-H)
    • 2000VA 1800W UPS:5 - 99%
    • GXT4-6000RT208 uninterruptible power supply (UPS) Double-conversion (Online) 6 kVA:0 - 95%

Side by side

Differences highlightedShow differences only (off)
Comparison of 38200003, GXT4-6000RT208
55 specifications
A

Equip

2000VA 1800W UPS

Model 38200003

View product
Features5 differ
Output power capacityDiffers2 kVA6 kVA
Output powerDiffers1800 W4800 W
Input operation voltage (min)Differs220 V120 V
Input operation voltage (max)Differs240 V208 V
Input frequencyDiffers50/60 Hz40/70 Hz
Output voltage regulationKnown for one5%Unknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Output power factorKnown for one0.9Unknown — not stated by the source
Crest factorKnown for one3:1Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one3%Unknown — not stated by the source
Noise levelKnown for one47 dBUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresKnown for oneOverheating, Overload, Short circuitUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
UPS topologyKnown for oneUnknown — not stated by the sourceDouble-conversion (Online)
WaveformKnown for oneUnknown — not stated by the sourceSine
Output operation voltage (min)Known for oneUnknown — not stated by the source120 V
Output operation voltage (max)Known for oneUnknown — not stated by the source208 V
Maximum currentKnown for oneUnknown — not stated by the source30 A
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
Ports & interfaces1 differ
AC outlet typesDiffersC13 couplerTerminal
AC outlets quantityKnown for one8 AC outlet(s)Unknown — not stated by the source
Number of type F outputsKnown for one8Unknown — not stated by the source
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one2Unknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceTerminal
Battery1 differ
Battery capacity9 Ah9 Ah
Battery voltage12 V12 V
Number of batteries supportedDiffers46
Typical backup time at full loadKnown for one3 minUnknown — not stated by the source
Battery recharge timeKnown for one4 hUnknown — not stated by the source
Charging currentKnown for one1.5 AUnknown — not stated by the source
Automatic battery testKnown for oneYesUnknown — not stated by the source
Battery technologyKnown for oneUnknown — not stated by the sourceSealed Lead Acid (VRLA)
Designidentical
Form factorRackmount/TowerRackmount/Tower
Product colourBlackBlack
Rack capacityKnown for one2UUnknown — not stated by the source
Display typeLCDLCD
Cable lengthKnown for oneUnknown — not stated by the source3 m
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)Differs5 - 99%0 - 95%
Storage temperature (T-T)Known for oneUnknown — not stated by the source-15 - 50 °C
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Weight & dimensions3 differ
WidthDiffers86.5 mm430 mm
DepthDiffers438 mm662 mm
HeightDiffers436 mm173 mm
WeightKnown for oneUnknown — not stated by the source69.9 kg
Other featuresidentical
Number of phasesKnown for one1Unknown — not stated by the source
Sustainabilityidentical
Sustainability certificatesKnown for oneUnknown — not stated by the sourceENERGY STAR
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceUL 1778, c-U
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceFCC A, IEEE/ANSI C62.41 A