Product comparison · 2 uninterruptible power supplies (upss)

Dahua Technology DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA vs Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA

Add a product
  • 17specifications compared
  • 13differ
  • 4identical
  • 47known for one product only

Key differences

The Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 1 kVA more output power capacity than the Dahua Technology DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA (3 kVA vs 2 kVA). The Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 1,000 W more output power than the Dahua Technology DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA (3000 W vs 2000 W). The Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA has 130 V more input operation voltage (min) than the Dahua Technology DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA (220 V vs 90 V). Waveform: Pure sine on the Dahua Technology DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA, Sine on the Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA. AC outlets quantity: 3 AC outlet(s) on the Dahua Technology DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA, 7 AC outlet(s) on the Legrand Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA.

  • Output power capacity
    • DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:2 kVA
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3 kVA
  • Output power
    • DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:2000 W
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:3000 W
  • Waveform
    • DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:Pure sine
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:Sine
  • Input operation voltage (min)
    • DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:90 V
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:220 V
  • Input operation voltage (max)
    • DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:300 V
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:240 V
  • Output power factor
    • DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:0.9
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:1
  • AC outlets quantity
    • DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:3 AC outlet(s)
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:7 AC outlet(s)
  • Battery voltage
    • DH-PFM3355-2000L uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA:72 V
    • Keor -DK-3000-B uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA:12 V

Side by side

Differences highlightedShow differences only (off)
Comparison of DH-PFM3355-2000L, Keor-DK-3000-B
64 specifications
Features6 differ
UPS topologyDouble-conversion (Online)Double-conversion (Online)
Output power capacityDiffers2 kVA3 kVA
Output powerDiffers2000 W3000 W
WaveformDiffersPure sineSine
Input operation voltage (min)Differs90 V220 V
Input operation voltage (max)Differs300 V240 V
Input frequency50/60 Hz50/60 Hz
Output operation voltage (max)Known for one230 VUnknown — not stated by the source
Output frequencyKnown for one50 HzUnknown — not stated by the source
Maximum currentKnown for one12 AUnknown — not stated by the source
Response timeKnown for one4 msUnknown — not stated by the source
Input power factorKnown for one0.9Unknown — not stated by the source
Output power factorDiffers0.91
Power protection featuresKnown for oneOverload, Overcharge, OverdischargeUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Overload alarm, Low battery alarm, FaultUnknown — not stated by the source
EfficiencyKnown for oneUnknown — not stated by the source98%
Efficiency (On-line mode)Known for oneUnknown — not stated by the source96%
Efficiency (ECO mode)Known for oneUnknown — not stated by the source98.3%
Power factorKnown for oneUnknown — not stated by the source1
Crest factorKnown for oneUnknown — not stated by the source3:1
ECO modeKnown for oneUnknown — not stated by the sourceYes
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces1 differ
AC outlets quantityDiffers3 AC outlet(s)7 AC outlet(s)
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
USB port typeKnown for oneUSB Type-BUnknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
AC outlet typesKnown for oneUnknown — not stated by the sourceC19 coupler, C13 coupler
USB portKnown for oneUnknown — not stated by the sourceYes
Network card slotKnown for oneUnknown — not stated by the sourceYes
Battery1 differ
Battery technologyKnown for oneLead-AcidUnknown — not stated by the source
Battery voltageDiffers72 V12 V
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Number of batteries includedKnown for oneUnknown — not stated by the source6 pc(s)
Number of battery cellsKnown for oneUnknown — not stated by the source6
Battery recharge timeKnown for oneUnknown — not stated by the source4 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Design2 differ
Form factorDiffersRackmountRackmount/Tower
Product colourDiffersBlack, GreyBlack, White
Housing materialKnown for oneMetal, PlasticUnknown — not stated by the source
Cable lengthKnown for one1.5 mUnknown — not stated by the source
Cooling typeKnown for oneActiveUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
Rack capacityKnown for oneUnknown — not stated by the source2U
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-15 - 55 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 90%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 90%Unknown — not stated by the source
Packaging contentidentical
Rack mount kitKnown for oneYesUnknown — not stated by the source
Cables includedKnown for oneRS-232, Input power cableUnknown — not stated by the source
ManualYesYes
Quick installation guideKnown for oneUnknown — not stated by the sourceYes
Certificatesidentical
CertificationKnown for oneCE LVD: EN IEC 62040-1: 2019+A11: 2021; CE EMC: EN IEC 62040-2: 2018; EN 62040-2: 2006; EN IEC 61000-3-2: 2019+A2: 2024; EN 61000-3-3: 2013+A2: 2021Unknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers482.6 mm440 mm
DepthDiffers429.2 mm640 mm
Height88 mm88 mm
WeightDiffers8.1 kg2.7 kg
Packaging dataidentical
Package widthKnown for one570 mmUnknown — not stated by the source
Package depthKnown for one540 mmUnknown — not stated by the source
Package heightKnown for one185 mmUnknown — not stated by the source
Package weightKnown for one10.8 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.