  • UPS topology
    • LCD Line-Interactive USV 750VA/750WTower, PFC, AVR, GreenPower, , Built in Cloud Interface, USB, Smart-Slot:Line-Interactive
    • Keor HPE:Double-conversion (Online)
  • Output power capacity
    • LCD Line-Interactive USV 750VA/750WTower, PFC, AVR, GreenPower, , Built in Cloud Interface, USB, Smart-Slot:0.75 kVA
    • Keor HPE:80 kVA
  • Output power
    • LCD Line-Interactive USV 750VA/750WTower, PFC, AVR, GreenPower, , Built in Cloud Interface, USB, Smart-Slot:750 W
    • Keor HPE:80000 W
  • Input operation voltage (min)
    • LCD Line-Interactive USV 750VA/750WTower, PFC, AVR, GreenPower, , Built in Cloud Interface, USB, Smart-Slot:160 V
    • Keor HPE:320 V
  • Input operation voltage (max)
    • LCD Line-Interactive USV 750VA/750WTower, PFC, AVR, GreenPower, , Built in Cloud Interface, USB, Smart-Slot:286 V
    • Keor HPE:480 V
  • Input frequency
    • LCD Line-Interactive USV 750VA/750WTower, PFC, AVR, GreenPower, , Built in Cloud Interface, USB, Smart-Slot:50/60 Hz
    • Keor HPE:45/65 Hz
  • Output operation voltage (min)
    • LCD Line-Interactive USV 750VA/750WTower, PFC, AVR, GreenPower, , Built in Cloud Interface, USB, Smart-Slot:200 V
    • Keor HPE:380 V
  • Output operation voltage (max)
    • LCD Line-Interactive USV 750VA/750WTower, PFC, AVR, GreenPower, , Built in Cloud Interface, USB, Smart-Slot:240 V
    • Keor HPE:415 V

Side by side

Differences highlightedShow differences only (off)
Comparison of PR750ELCD3C, Keor HPE
67 specifications
Features8 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers0.75 kVA80 kVA
Output powerDiffers750 W80000 W
WaveformKnown for onePure sineUnknown — not stated by the source
Input operation voltage (min)Differs160 V320 V
Input operation voltage (max)Differs286 V480 V
Input frequencyDiffers50/60 Hz45/65 Hz
Output operation voltage (min)Differs200 V380 V
Output operation voltage (max)Differs240 V415 V
Output frequency50/60 Hz50/60 Hz
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Maximum currentKnown for one10 AUnknown — not stated by the source
Surge energy ratingKnown for one410 JUnknown — not stated by the source
Heat dissipationKnown for one23.94 BTU/hUnknown — not stated by the source
Output power factor11
Emergency Power Off (EPO)YesYes
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarm, FaultUnknown — not stated by the source
Socket circuit breakerKnown for oneYesUnknown — not stated by the source
Number of input phasesKnown for oneUnknown — not stated by the source3
Number of output phasesKnown for oneUnknown — not stated by the source3
EfficiencyKnown for oneUnknown — not stated by the source95%
Efficiency (ECO mode)Known for oneUnknown — not stated by the source99%
ECO modeKnown for oneUnknown — not stated by the sourceYes
Noise levelKnown for oneUnknown — not stated by the source60 dB
Ports & interfacesidentical
AC outlet typesKnown for oneC13 couplerUnknown — not stated by the source
AC outlets quantityKnown for one8 AC outlet(s)Unknown — not stated by the source
USB portKnown for oneYesUnknown — not stated by the source
USB port typeKnown for oneUSB Type-BUnknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
Batteryidentical
Battery replacement accessibilityKnown for oneEnd-userUnknown — not stated by the source
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Number of batteries supportedKnown for one1Unknown — not stated by the source
Typical backup time at full loadKnown for one4 minUnknown — not stated by the source
Battery recharge timeKnown for one3 hUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Replacement battery cartridgeKnown for oneRBP0203Unknown — not stated by the source
Design1 differ
Form factorKnown for oneTowerUnknown — not stated by the source
Product colourDiffersBlackWhite, Black
Housing materialKnown for oneMetalUnknown — not stated by the source
Cable lengthKnown for one1.83 mUnknown — not stated by the source
Built-in fanKnown for oneNoUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsKnown for oneYesUnknown — not stated by the source
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP20
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Differs-15 - 45 °C-20 - 50 °C
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneCE, RoHSUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers138 mm560 mm
DepthDiffers360 mm940 mm
HeightDiffers162 mm1500 mm
WeightDiffers12.1 kg250 kg
Packaging dataidentical
Package widthKnown for one483 mmUnknown — not stated by the source
Package depthKnown for one263 mmUnknown — not stated by the source
Package heightKnown for one285 mmUnknown — not stated by the source
Package weightKnown for one13.8 kgUnknown — not stated by the source
Other featuresidentical
BypassKnown for oneGreenPower UPSUnknown — not stated by the source
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes