  • Output power capacity
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:0.5 kVA
    • Eufo EU-1102TS:2 kVA
  • Output power
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:400 W
    • Eufo EU-1102TS:1600 W
  • Input operation voltage (min)
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:80 V
    • Eufo EU-1102TS:110 V
  • Input operation voltage (max)
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:150 V
    • Eufo EU-1102TS:240 V
  • Input frequency
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:57/63 Hz
    • Eufo EU-1102TS:50/60 Hz
  • Output operation voltage (max)
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:120 V
    • Eufo EU-1102TS:240 V
  • AC outlet types
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:NEMA 5–15R
    • Eufo EU-1102TS:C13 coupler
  • Power plug
    • PR500LCDRT1U uninterruptible power supply (UPS) Line-Interactive 0.5 kVA:NEMA 5-15P
    • Eufo EU-1102TS:C14 coupler

Side by side

Differences highlightedShow differences only (on)
Comparison of PR500LCDRT1U, Eufo EU-1102TS
64 specifications
Features6 differ
UPS topologyKnown for oneLine-InteractiveUnknown — not stated by the source
Output power capacityDiffers0.5 kVA2 kVA
Output powerDiffers400 W1600 W
Input operation voltage (min)Differs80 V110 V
Input operation voltage (max)Differs150 V240 V
Input frequencyDiffers57/63 Hz50/60 Hz
Output operation voltage (max)Differs120 V240 V
Output frequencyKnown for one60 HzUnknown — not stated by the source
Surge energy ratingKnown for one1030 JUnknown — not stated by the source
Power factorKnown for one0.8Unknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Output operation voltage (min)Known for oneUnknown — not stated by the source110 V
Output voltage regulationKnown for oneUnknown — not stated by the source6%
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
EfficiencyKnown for oneUnknown — not stated by the source88%
Output power factorKnown for oneUnknown — not stated by the source0.8
Crest factorKnown for oneUnknown — not stated by the source3:1
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source8%
Noise levelKnown for oneUnknown — not stated by the source45 dB
Ports & interfaces3 differ
AC outlet typesDiffersNEMA 5–15RC13 coupler
Power plugDiffersNEMA 5-15PC14 coupler
AC outlets quantityDiffers7 AC outlet(s)8 AC outlet(s)
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
Serial ports quantityKnown for one1Unknown — not stated by the source
Battery2 differ
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Number of batteries supportedDiffers24
Typical backup time at full loadKnown for one3 minUnknown — not stated by the source
Typical backup time at half loadKnown for one12 minUnknown — not stated by the source
Battery recharge timeDiffers6 h4 h
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Battery voltageKnown for oneUnknown — not stated by the source48 V
Design1 differ
Form factorDiffersRackmount/TowerTower
Rack capacityKnown for one1UUnknown — not stated by the source
Cable lengthKnown for one3 mUnknown — not stated by the source
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Operational conditionsidentical
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source20 - 90%
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceIEC 62040-1 IEC-62040-2 CE
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUL1778, CSA C22.2 NO.107.3-05, FCC DOC Class AUnknown — not stated by the source
Weight & dimensionsidentical
WidthKnown for one438.1 mmUnknown — not stated by the source
DepthKnown for one241.3 mmUnknown — not stated by the source
HeightKnown for one44.5 mmUnknown — not stated by the source
WeightKnown for one8.98 kgUnknown — not stated by the source
Packaging dataidentical
Package widthKnown for one528.3 mmUnknown — not stated by the source
Package depthKnown for one335.3 mmUnknown — not stated by the source
Package heightKnown for one157.5 mmUnknown — not stated by the source
Package weightKnown for one11.5 kgUnknown — not stated by the source
Other featuresidentical
Output voltageKnown for one120 VUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.