Product comparison · 2 uninterruptible power supplies (upss)

CyberPower PR3000ERT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA vs CyberPower PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA

Add a product
  • 62specifications compared
  • 9differ
  • 53identical
  • 24known for one product only

Key differences

  • Maximum current
    • PR3000ERT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:10 A
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:16 A
  • Power protection features
    • PR3000ERT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:Overload
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:Overload, Short circuit
  • Number of batteries supported
    • PR3000ERT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:1
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:4
  • Typical backup time at full load
    • PR3000ERT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:1.3 min
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:1.7 min
  • Typical backup time at half load
    • PR3000ERT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:6.4 min
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:7.1 min
  • LED indicators
    • PR3000ERT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:Fault, Power, Status
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:Error, Operation
  • Weight
    • PR3000ERT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:32.3 kg
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:32.8 kg
  • Package weight
    • PR3000ERT2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:40.3 kg
    • PR3000ERTXL2U uninterruptible power supply (UPS) Line-Interactive 3 kVA:41 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of PR3000ERT2U, PR3000ERTXL2U
86 specifications
Features3 differ
Maximum currentDiffers10 A16 A
Heat dissipationKnown for one120.8 BTU/hUnknown — not stated by the source
Number of output phasesKnown for one1Unknown — not stated by the source
Emergency Power Off (EPO)Known for oneYesUnknown — not stated by the source
Noise levelKnown for one57.5 dBUnknown — not stated by the source
Surge protection featuresKnown for oneNetworkUnknown — not stated by the source
Power protection featuresDiffersOverloadOverload, Short circuit
Audible alarm modesDiffersAlarm when on battery, Fault, Low battery alarm, Overload alarmAlarm when on battery, Low battery alarm, Overload alarm
Transfer time (Line Mode to Battery Mode)Known for oneUnknown — not stated by the source4 ms
Web-based managementKnown for oneUnknown — not stated by the sourceYes
Socket circuit breakerKnown for oneUnknown — not stated by the sourceYes
Ports & interfacesidentical
RS-232 portsKnown for one1Unknown — not stated by the source
Serial ports quantityKnown for one1Unknown — not stated by the source
Cabling technologyKnown for oneUnknown — not stated by the source10/100/1000Base-T(X)
Battery3 differ
Number of batteries supportedDiffers14
Typical backup time at full loadDiffers1.3 min1.7 min
Typical backup time at half loadDiffers6.4 min7.1 min
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceRBP0129
Design1 differ
Cooling typeKnown for oneActiveUnknown — not stated by the source
Built-in fanKnown for oneYesUnknown — not stated by the source
Control typeKnown for oneButtonsUnknown — not stated by the source
LED indicatorsDiffersFault, Power, StatusError, Operation
Packaging contentidentical
Rack mount kitKnown for oneYesUnknown — not stated by the source
Cables includedKnown for oneSerial, USB cableUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceCE , FCC Class A , UL , CISPR 22 Class A , IEC62040-2 , RCM , VCCI , EN 61000-3-2
Sustainabilityidentical
Sustainability complianceKnown for oneYesUnknown — not stated by the source
Weight & dimensions1 differ
WeightDiffers32.3 kg32.8 kg
Packaging data1 differ
Package weightDiffers40.3 kg41 kg
Package volumeKnown for oneUnknown — not stated by the source40800 cm³
Logistics dataidentical
Warranty periodKnown for one3 year(s)Unknown — not stated by the source
Other featuresidentical
Battery typeKnown for oneRBP0129Unknown — not stated by the source
BypassKnown for oneUnknown — not stated by the sourceGreenPower UPS