Product comparison · 2 uninterruptible power supplies (upss)

CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA vs FSP Proline TW 30 kVA

Add a product
  • 17specifications compared
  • 11differ
  • 6identical
  • 31known for one product only

Key differences

The FSP Proline TW 30 kVA has 27 kVA more output power capacity than the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA (30 kVA vs 3 kVA). The FSP Proline TW 30 kVA has 21,600 W more output power than the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA (24000 W vs 2400 W). The FSP Proline TW 30 kVA has 40 V more input operation voltage (min) than the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA (190 V vs 150 V). Input frequency: 50/60 Hz on the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA, 46/64 Hz on the FSP Proline TW 30 kVA. AC outlet types: C13 coupler, C19 coupler on the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA, Terminal on the FSP Proline TW 30 kVA.

  • Output power capacity
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:3 kVA
    • Proline TW 30 kVA:30 kVA
  • Output power
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:2400 W
    • Proline TW 30 kVA:24000 W
  • Input operation voltage (min)
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:150 V
    • Proline TW 30 kVA:190 V
  • Input operation voltage (max)
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:300 V
    • Proline TW 30 kVA:520 V
  • Input frequency
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:50/60 Hz
    • Proline TW 30 kVA:46/64 Hz
  • AC outlet types
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:C13 coupler, C19 coupler
    • Proline TW 30 kVA:Terminal
  • Form factor
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:Rackmount
    • Proline TW 30 kVA:Tower
  • Width
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:433 mm
    • Proline TW 30 kVA:250 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of PR3000ELCDRTXL2U, Proline TW 30 kVA
48 specifications
Features5 differ
Output power capacityDiffers3 kVA30 kVA
Output powerDiffers2400 W24000 W
WaveformSineSine
Input operation voltage (min)Differs150 V190 V
Input operation voltage (max)Differs300 V520 V
Input frequencyDiffers50/60 Hz46/64 Hz
Output voltage regulationKnown for oneUnknown — not stated by the source2%
Number of input phasesKnown for oneUnknown — not stated by the source3
Number of output phasesKnown for oneUnknown — not stated by the source3
EfficiencyKnown for oneUnknown — not stated by the source89%
Output power factorKnown for oneUnknown — not stated by the source0.8
Crest factorKnown for oneUnknown — not stated by the source3:1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source2%
Noise levelKnown for oneUnknown — not stated by the source58 dB
Audible alarm(s)YesYes
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Surge protection featuresKnown for oneFax, Modem, Network, TelephoneUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesDiffersC13 coupler, C19 couplerTerminal
Power plugKnown for oneUnknown — not stated by the sourceTerminal
AC outlets quantityKnown for one9 AC outlet(s)Unknown — not stated by the source
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Batteryidentical
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Battery voltage12 V12 V
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Number of batteries supportedKnown for one4Unknown — not stated by the source
Typical backup time at full loadKnown for one3 minUnknown — not stated by the source
Typical backup time at half loadKnown for one8 minUnknown — not stated by the source
Battery recharge timeKnown for one6 hUnknown — not stated by the source
Design1 differ
Form factorDiffersRackmountTower
Product colourBlackBlack
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Display typeLCDLCD
LED indicatorsYesYes
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 40 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 90%
Safety regulation & standardsidentical
SafetyKnown for oneUnknown — not stated by the sourceIEC 62040-1
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceIEC-62040-2 CE
Weight & dimensions4 differ
WidthDiffers433 mm250 mm
DepthDiffers630 mm815 mm
HeightDiffers88 mm826 mm
WeightDiffers42 kg62 kg
Other featuresidentical
Compatible operating systemsKnown for oneUnknown — not stated by the sourceWindows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, MAC
Management platformKnown for oneUnknown — not stated by the sourceSNMP, USB, RS-232
Nominal output voltageKnown for oneUnknown — not stated by the source400 V

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons