Product comparison · 2 uninterruptible power supplies (upss)

CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA vs FSP Knight KN-1103TS Tower

Add a product
  • 20specifications compared
  • 10differ
  • 10identical
  • 25known for one product only

Key differences

The CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA has 40 V more input operation voltage (min) than the FSP Knight KN-1103TS Tower (150 V vs 110 V). The FSP Knight KN-1103TS Tower has 2 more batteries supported than the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA (6 vs 4). The CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA has 2 h more battery recharge time than the FSP Knight KN-1103TS Tower (6 h vs 4 h). Input frequency: 50/60 Hz on the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA, 47/63 Hz on the FSP Knight KN-1103TS Tower. AC outlets quantity: 9 AC outlet(s) on the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA, 7 AC outlet(s) on the FSP Knight KN-1103TS Tower.

  • Input operation voltage (min)
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:150 V
    • Knight KN-1103TS Tower:110 V
  • Input frequency
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:50/60 Hz
    • Knight KN-1103TS Tower:47/63 Hz
  • AC outlets quantity
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:9 AC outlet(s)
    • Knight KN-1103TS Tower:7 AC outlet(s)
  • Number of batteries supported
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:4
    • Knight KN-1103TS Tower:6
  • Battery recharge time
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:6 h
    • Knight KN-1103TS Tower:4 h
  • Form factor
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:Rackmount
    • Knight KN-1103TS Tower:Tower
  • Width
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:433 mm
    • Knight KN-1103TS Tower:119 mm
  • Depth
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:630 mm
    • Knight KN-1103TS Tower:419 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of PR3000ELCDRTXL2U, Knight KN-1103TS Tower
45 specifications
Features2 differ
Input operation voltage (min)Differs150 V110 V
Input frequencyDiffers50/60 Hz47/63 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source208 V
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
Output voltage regulationKnown for oneUnknown — not stated by the source1%
Number of input phasesKnown for oneUnknown — not stated by the source1
EfficiencyKnown for oneUnknown — not stated by the source90%
Power factorKnown for oneUnknown — not stated by the source0.99
Output power factorKnown for oneUnknown — not stated by the source0.8
Crest factorKnown for oneUnknown — not stated by the source3:1
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source2%
Noise levelKnown for oneUnknown — not stated by the source50 dB
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Surge protection featuresKnown for oneFax, Modem, Network, TelephoneUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Ports & interfaces1 differ
Power plugKnown for oneUnknown — not stated by the sourceC20 coupler
AC outlets quantityDiffers9 AC outlet(s)7 AC outlet(s)
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Battery2 differ
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Number of batteries supportedDiffers46
Battery recharge timeDiffers6 h4 h
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Typical backup time at full loadKnown for one3 minUnknown — not stated by the source
Typical backup time at half loadKnown for one8 minUnknown — not stated by the source
Design1 differ
Form factorDiffersRackmountTower
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 40 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source20 - 90%
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceIEC 62040-1 IEC-62040-2 CE
Weight & dimensions4 differ
WidthDiffers433 mm119 mm
DepthDiffers630 mm419 mm
HeightDiffers88 mm318 mm
WeightDiffers42 kg28 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.