Product comparison · 2 uninterruptible power supplies (upss)

CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA vs FSP IndusPower IN-3380TL

Add a product
  • 15specifications compared
  • 11differ
  • 4identical
  • 25known for one product only

Key differences

The FSP IndusPower IN-3380TL has 77 kVA more output power capacity than the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA (80 kVA vs 3 kVA). The FSP IndusPower IN-3380TL has 61,600 W more output power than the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA (64000 W vs 2400 W). The FSP IndusPower IN-3380TL has 732 V more battery voltage than the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA (744 V vs 12 V). Power protection features: Overload on the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA, Overload, Short circuit on the FSP IndusPower IN-3380TL. AC outlet types: C13 coupler, C19 coupler on the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA, Terminal on the FSP IndusPower IN-3380TL.

  • Output power capacity
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:3 kVA
    • IndusPower IN-3380TL:80 kVA
  • Output power
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:2400 W
    • IndusPower IN-3380TL:64000 W
  • Power protection features
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:Overload
    • IndusPower IN-3380TL:Overload, Short circuit
  • AC outlet types
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:C13 coupler, C19 coupler
    • IndusPower IN-3380TL:Terminal
  • Battery voltage
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:12 V
    • IndusPower IN-3380TL:744 V
  • Number of batteries supported
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:4
    • IndusPower IN-3380TL:62
  • Form factor
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:Rackmount
    • IndusPower IN-3380TL:Tower
  • Width
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:433 mm
    • IndusPower IN-3380TL:590 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of PR3000ELCDRTXL2U, IndusPower IN-3380TL
40 specifications
Features3 differ
Output power capacityDiffers3 kVA80 kVA
Output powerDiffers2400 W64000 W
Input operation voltage (min)Known for one150 VUnknown — not stated by the source
Input operation voltage (max)Known for one300 VUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Surge protection featuresKnown for oneFax, Modem, Network, TelephoneUnknown — not stated by the source
Power protection featuresDiffersOverloadOverload, Short circuit
Audible alarm(s)Known for oneYesUnknown — not stated by the source
Number of input phasesKnown for oneUnknown — not stated by the source3
Number of output phasesKnown for oneUnknown — not stated by the source3
EfficiencyKnown for oneUnknown — not stated by the source94%
Input power factorKnown for oneUnknown — not stated by the source1
Output power factorKnown for oneUnknown — not stated by the source0.9
Crest factorKnown for oneUnknown — not stated by the source2.8:1
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source0.5%
Ports & interfaces1 differ
AC outlet typesDiffersC13 coupler, C19 couplerTerminal
AC outlets quantityKnown for one9 AC outlet(s)Unknown — not stated by the source
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Power plugKnown for oneUnknown — not stated by the sourceTerminal
Battery2 differ
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Battery voltageDiffers12 V744 V
Number of batteries supportedDiffers462
Typical backup time at full loadKnown for one3 minUnknown — not stated by the source
Typical backup time at half loadKnown for one8 minUnknown — not stated by the source
Battery recharge timeKnown for one6 hUnknown — not stated by the source
Design1 differ
Form factorDiffersRackmountTower
Display typeKnown for oneLCDUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers433 mm590 mm
DepthDiffers630 mm805 mm
HeightDiffers88 mm1320 mm
WeightDiffers42 kg230 kg
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceIEC 62040-1 IEC-62040-2 CE
Other featuresidentical
Nominal input voltageKnown for oneUnknown — not stated by the source400 V
Nominal output voltageKnown for oneUnknown — not stated by the source400 V

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.