Key differences

The CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA has 1.9 kVA more output power capacity than the FSP Eufo EU-1101TS (3 kVA vs 1.1 kVA). The CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA has 1,520 W more output power than the FSP Eufo EU-1101TS (2400 W vs 880 W). The CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA has 40 V more input operation voltage (min) than the FSP Eufo EU-1101TS (150 V vs 110 V). AC outlet types: C13 coupler, C19 coupler on the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA, C13 coupler on the FSP Eufo EU-1101TS. AC outlets quantity: 9 AC outlet(s) on the CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA, 8 AC outlet(s) on the FSP Eufo EU-1101TS.

  • Output power capacity
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:3 kVA
    • Eufo EU-1101TS:1.1 kVA
  • Output power
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:2400 W
    • Eufo EU-1101TS:880 W
  • Input operation voltage (min)
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:150 V
    • Eufo EU-1101TS:110 V
  • Input operation voltage (max)
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:300 V
    • Eufo EU-1101TS:240 V
  • AC outlet types
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:C13 coupler, C19 coupler
    • Eufo EU-1101TS:C13 coupler
  • AC outlets quantity
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:9 AC outlet(s)
    • Eufo EU-1101TS:8 AC outlet(s)
  • Battery voltage
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:12 V
    • Eufo EU-1101TS:24 V
  • Number of batteries supported
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:4
    • Eufo EU-1101TS:2

Side by side

Differences highlightedShow differences only (on)
Comparison of PR3000ELCDRTXL2U, Eufo EU-1101TS
47 specifications
Features4 differ
Output power capacityDiffers3 kVA1.1 kVA
Output powerDiffers2400 W880 W
Input operation voltage (min)Differs150 V110 V
Input operation voltage (max)Differs300 V240 V
Output operation voltage (min)Known for oneUnknown — not stated by the source110 V
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
Output voltage regulationKnown for oneUnknown — not stated by the source6%
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
EfficiencyKnown for oneUnknown — not stated by the source88%
Output power factorKnown for oneUnknown — not stated by the source0.8
Crest factorKnown for oneUnknown — not stated by the source3:1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source8%
Noise levelKnown for oneUnknown — not stated by the source45 dB
Surge protectionKnown for oneYesUnknown — not stated by the source
Surge protection featuresKnown for oneFax, Modem, Network, TelephoneUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Ports & interfaces2 differ
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler
Power plugKnown for oneUnknown — not stated by the sourceC14 coupler
AC outlets quantityDiffers9 AC outlet(s)8 AC outlet(s)
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Battery3 differ
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Battery voltageDiffers12 V24 V
Number of batteries supportedDiffers42
Battery recharge timeDiffers6 h4 h
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Typical backup time at full loadKnown for one3 minUnknown — not stated by the source
Typical backup time at half loadKnown for one8 minUnknown — not stated by the source
Design1 differ
Form factorDiffersRackmountTower
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 40 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source20 - 90%
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceIEC 62040-1 IEC-62040-2 CE
Weight & dimensionsidentical
WidthKnown for one433 mmUnknown — not stated by the source
DepthKnown for one630 mmUnknown — not stated by the source
HeightKnown for one88 mmUnknown — not stated by the source
WeightKnown for one42 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.