Product comparison · 2 uninterruptible power supplies (upss)

CyberPower PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA vs FSP Custos CU-1103TL

Add a product
  • 18specifications compared
  • 9differ
  • 9identical
  • 31known for one product only

Key differences

  • Output power
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:2400 W
    • Custos CU-1103TL:2700 W
  • Input operation voltage (min)
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:150 V
    • Custos CU-1103TL:55 V
  • Input frequency
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:50/60 Hz
    • Custos CU-1103TL:40/70 Hz
  • AC outlets quantity
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:9 AC outlet(s)
    • Custos CU-1103TL:7 AC outlet(s)
  • Form factor
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:Rackmount
    • Custos CU-1103TL:Tower
  • Width
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:433 mm
    • Custos CU-1103TL:88 mm
  • Depth
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:630 mm
    • Custos CU-1103TL:600 mm
  • Height
    • PR3000ELCDRTXL2U uninterruptible power supply (UPS) 3 kVA:88 mm
    • Custos CU-1103TL:438 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of PR3000ELCDRTXL2U, Custos CU-1103TL
49 specifications
Features3 differ
Output power capacity3 kVA3 kVA
Output powerDiffers2400 W2700 W
WaveformSineSine
Input operation voltage (min)Differs150 V55 V
Input operation voltage (max)300 V300 V
Input frequencyDiffers50/60 Hz40/70 Hz
Output operation voltage (min)Known for oneUnknown — not stated by the source110 V
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
Output voltage regulationKnown for oneUnknown — not stated by the source2%
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
EfficiencyKnown for oneUnknown — not stated by the source88%
Input power factorKnown for oneUnknown — not stated by the source0.99
Output power factorKnown for oneUnknown — not stated by the source0.9
Crest factorKnown for oneUnknown — not stated by the source5:1
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source2%
Noise levelKnown for oneUnknown — not stated by the source50 dB
Audible alarm(s)YesYes
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Surge protection featuresKnown for oneFax, Modem, Network, TelephoneUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Power plugKnown for oneUnknown — not stated by the sourceC20 coupler
AC outlets quantityDiffers9 AC outlet(s)7 AC outlet(s)
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Batteryidentical
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Battery voltage12 V12 V
Hot-swap batteryKnown for oneUnknown — not stated by the sourceYes
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Number of batteries supportedKnown for one4Unknown — not stated by the source
Typical backup time at full loadKnown for one3 minUnknown — not stated by the source
Typical backup time at half loadKnown for one8 minUnknown — not stated by the source
Battery recharge timeKnown for one6 hUnknown — not stated by the source
Design1 differ
Form factorDiffersRackmountTower
Product colourBlackBlack
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Display typeLCDLCD
LED indicatorsYesYes
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source0 - 40 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source20 - 90%
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceIEC 62040-1 IEC-62040-2 CE
Weight & dimensions4 differ
WidthDiffers433 mm88 mm
DepthDiffers630 mm600 mm
HeightDiffers88 mm438 mm
WeightDiffers42 kg13.8 kg
Other featuresidentical
Output connectionsKnown for oneUnknown — not stated by the source1 x IEC 320 C19 & 6 x IEC 320 C13

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.