Product comparison · 2 uninterruptible power supplies (upss)

CyberPower PR2200LCD uninterruptible power supply (UPS) Line-Interactive 2.2 kVA vs itek KingPower 2000

Add a product
  • 15specifications compared
  • 10differ
  • 5identical
  • 23known for one product only

Key differences

  • Output power capacity
    • PR2200LCD uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:2.2 kVA
    • KingPower 2000:2 kVA
  • Output power
    • PR2200LCD uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:1980 W
    • KingPower 2000:1600 W
  • Input operation voltage (min)
    • PR2200LCD uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:75 V
    • KingPower 2000:55 V
  • Input operation voltage (max)
    • PR2200LCD uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:154 V
    • KingPower 2000:300 V
  • Input frequency
    • PR2200LCD uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:47/63 Hz
    • KingPower 2000:40/70 Hz
  • Output operation voltage (min)
    • PR2200LCD uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:120 V
    • KingPower 2000:100 V
  • Output operation voltage (max)
    • PR2200LCD uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:120 V
    • KingPower 2000:240 V
  • AC outlets quantity
    • PR2200LCD uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:10 AC outlet(s)
    • KingPower 2000:8 AC outlet(s)

Side by side

Differences highlightedShow differences only (off)
Comparison of PR2200LCD, KingPower 2000
38 specifications
Features7 differ
UPS topologyKnown for oneLine-InteractiveUnknown — not stated by the source
Output power capacityDiffers2.2 kVA2 kVA
Output powerDiffers1980 W1600 W
Input operation voltage (min)Differs75 V55 V
Input operation voltage (max)Differs154 V300 V
Input frequencyDiffers47/63 Hz40/70 Hz
Output operation voltage (min)Differs120 V100 V
Output operation voltage (max)Differs120 V240 V
Surge energy ratingKnown for one1030 JUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Audible alarm(s)YesYes
EfficiencyKnown for oneUnknown — not stated by the source90%
Crest factorKnown for oneUnknown — not stated by the source3:1
Noise levelKnown for oneUnknown — not stated by the source50 dB
Ports & interfaces1 differ
AC outlet typesKnown for oneNEMA 5–15R, NEMA 5–20RUnknown — not stated by the source
Power plugKnown for oneNEMA L5-30PUnknown — not stated by the source
AC outlets quantityDiffers10 AC outlet(s)8 AC outlet(s)
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
RS-232 portsKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Batteryidentical
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Typical backup time at full loadKnown for one8 minUnknown — not stated by the source
Typical backup time at half loadKnown for one26 minUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Battery recharge timeKnown for oneUnknown — not stated by the source4 h
Designidentical
Form factorTowerTower
Product colourBlackBlack
Display typeLCDLCD
LED indicatorsKnown for oneYesUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Operating relative humidity (H-H)Differs0 - 90%20 - 90%
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneUL1778, cUL CSA C22.2 No. 107.3, FCC DOC BUnknown — not stated by the source
Other features1 differ
Battery typeDiffersRB121706x 12 V / 7 Ah
Weight & dimensionsidentical
WidthKnown for oneUnknown — not stated by the source190 mm
DepthKnown for oneUnknown — not stated by the source421 mm
HeightKnown for oneUnknown — not stated by the source318 mm
WeightKnown for oneUnknown — not stated by the source26 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.