Key differences

The CyberPower PR2200ERT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA has 1.6 kVA more output power capacity than the Legrand ASI KEOR SP 600 IEC (2.2 kVA vs 0.6 kVA). The CyberPower PR2200ERT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA has 1,840 W more output power than the Legrand ASI KEOR SP 600 IEC (2200 W vs 360 W). The Legrand ASI KEOR SP 600 IEC has 11 V more input operation voltage (min) than the CyberPower PR2200ERT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA (170 V vs 159 V). Only the CyberPower PR2200ERT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA has serial interface. Waveform: Pure sine on the CyberPower PR2200ERT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA, Sine on the Legrand ASI KEOR SP 600 IEC.

  • Output power capacity
    • PR2200ERT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:2.2 kVA
    • ASI KEOR SP 600 IEC:0.6 kVA
  • Output power
    • PR2200ERT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:2200 W
    • ASI KEOR SP 600 IEC:360 W
  • Waveform
    • PR2200ERT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:Pure sine
    • ASI KEOR SP 600 IEC:Sine
  • Input operation voltage (min)
    • PR2200ERT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:159 V
    • ASI KEOR SP 600 IEC:170 V
  • Input operation voltage (max)
    • PR2200ERT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:288 V
    • ASI KEOR SP 600 IEC:280 V
  • Input frequency
    • PR2200ERT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:50/60 Hz
    • ASI KEOR SP 600 IEC:45/65 Hz
  • Output operation voltage (min)
    • PR2200ERT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:220 V
    • ASI KEOR SP 600 IEC:207 V
  • Output operation voltage (max)
    • PR2200ERT2U uninterruptible power supply (UPS) Line-Interactive 2.2 kVA:240 V
    • ASI KEOR SP 600 IEC:253 V

Side by side

Differences highlightedShow differences only (on)
Comparison of PR2200ERT2U, ASI KEOR SP 600 IEC
86 specifications
Features10 differ
Output power capacityDiffers2.2 kVA0.6 kVA
Output powerDiffers2200 W360 W
WaveformDiffersPure sineSine
Input operation voltage (min)Differs159 V170 V
Input operation voltage (max)Differs288 V280 V
Input frequencyDiffers50/60 Hz45/65 Hz
Output operation voltage (min)Differs220 V207 V
Output operation voltage (max)Differs240 V253 V
Surge energy ratingKnown for one2430 JUnknown — not stated by the source
Transfer time (Line Mode to Battery Mode)Known for one4 msUnknown — not stated by the source
Power factorKnown for one1Unknown — not stated by the source
Power Factor Correction (PFC) typeKnown for oneActiveUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Noise levelDiffers52.5 dB40 dB
Power protection featuresDiffersOverload, Short circuitOvercharge, Overdischarge, Overload, Short circuit
Web-based managementKnown for oneYesUnknown — not stated by the source
Audible alarm modesKnown for oneAlarm when on battery, Low battery alarmUnknown — not stated by the source
Socket circuit breakerKnown for oneYesUnknown — not stated by the source
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Output frequency regulationKnown for oneUnknown — not stated by the source1 Hz
Output voltage regulationKnown for oneUnknown — not stated by the source10%
Number of output phasesKnown for oneUnknown — not stated by the source1
EfficiencyKnown for oneUnknown — not stated by the source96%
Output power factorKnown for oneUnknown — not stated by the source0.6
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Potential-free outputKnown for oneUnknown — not stated by the sourceNo
Auto shut-offKnown for oneUnknown — not stated by the sourceNo
Power source typeKnown for oneUnknown — not stated by the sourceAC
Ports & interfaces4 differ
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler
Power plugDiffersC20 couplerC14 coupler
AC outlets quantityDiffers8 AC outlet(s)4 AC outlet(s)
Serial interfaceDiffersYesNo
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one2Unknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
USB port typeKnown for oneUnknown — not stated by the sourceUSB Type-B
Batteryidentical
Typical backup time at full loadKnown for one3 minUnknown — not stated by the source
Typical backup time at half loadKnown for one11.4 minUnknown — not stated by the source
Battery recharge timeKnown for one3 hUnknown — not stated by the source
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source7 Ah
Design2 differ
Form factorDiffersRackmount/TowerMini Tower
Product colourDiffersBlackBlack, White
Housing materialKnown for oneMetalUnknown — not stated by the source
Rack capacityKnown for one2UUnknown — not stated by the source
Cable lengthKnown for one2.4 mUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
Operational conditionsidentical
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificates2 differ
Compliance certificatesDiffersRoHSCE
CertificationDiffersCE , FCC Class B , UL , RCM , VCCIEN 62040-1, EN 62040-2
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Sustainability complianceKnown for oneUnknown — not stated by the sourceYes
Weight & dimensions4 differ
WidthDiffers433 mm120 mm
DepthDiffers412 mm330 mm
HeightDiffers86.5 mm138 mm
WeightDiffers25.7 kg5 kg
Packaging data4 differ
Package widthDiffers560 mm120 mm
Package depthDiffers530 mm5.46 mm
Package heightDiffers275 mm138 mm
Package weightDiffers33.5 kg5.45 kg
Other featuresidentical
BypassKnown for oneGreenPower UPSUnknown — not stated by the source
Logistics dataidentical
Products per palletKnown for oneUnknown — not stated by the source60 pc(s)
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85078000
Pallet net heightKnown for oneUnknown — not stated by the source135 cm
Pallet net lengthKnown for oneUnknown — not stated by the source100 cm
Pallet net weightKnown for oneUnknown — not stated by the source344.1 kg
Pallet net widthKnown for oneUnknown — not stated by the source120 cm
Master (outer) case widthKnown for oneUnknown — not stated by the source192 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source392 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source218 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source5.74 kg
Products per master (outer) caseKnown for oneUnknown — not stated by the source1 pc(s)