Product comparison · 2 uninterruptible power supplies (upss)

CyberPower PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA vs Legrand Keor HPE

Add a product
  • 19specifications compared
  • 17differ
  • 2identical
  • 33known for one product only

Key differences

The Legrand Keor HPE has 78 kVA more output power capacity than the CyberPower PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA (80 kVA vs 2 kVA). The Legrand Keor HPE has 78,000 W more output power than the CyberPower PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA (80000 W vs 2000 W). The Legrand Keor HPE has 189 V more input operation voltage (min) than the CyberPower PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA (320 V vs 131 V). UPS topology: Line-Interactive on the CyberPower PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA, Double-conversion (Online) on the Legrand Keor HPE. Input frequency: 50/60 Hz on the CyberPower PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA, 45/65 Hz on the Legrand Keor HPE.

  • UPS topology
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:Line-Interactive
    • Keor HPE:Double-conversion (Online)
  • Output power capacity
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:2 kVA
    • Keor HPE:80 kVA
  • Output power
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:2000 W
    • Keor HPE:80000 W
  • Input operation voltage (min)
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:131 V
    • Keor HPE:320 V
  • Input operation voltage (max)
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:302 V
    • Keor HPE:480 V
  • Input frequency
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:50/60 Hz
    • Keor HPE:45/65 Hz
  • Output operation voltage (min)
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:200 V
    • Keor HPE:380 V
  • Output operation voltage (max)
    • PR2000ERTXL2UC uninterruptible power supply (UPS) Line-Interactive 2 kVA:240 V
    • Keor HPE:415 V

Side by side

Differences highlightedShow differences only (on)
Comparison of PR2000ERTXL2UC, Keor HPE
52 specifications
Features11 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers2 kVA80 kVA
Output powerDiffers2000 W80000 W
WaveformKnown for onePure sineUnknown — not stated by the source
Input operation voltage (min)Differs131 V320 V
Input operation voltage (max)Differs302 V480 V
Input frequencyDiffers50/60 Hz45/65 Hz
Output operation voltage (min)Differs200 V380 V
Output operation voltage (max)Differs240 V415 V
Number of input phasesDiffers13
Number of output phasesDiffers13
Noise levelDiffers38.5 dB60 dB
Power protection featuresKnown for oneOvercharge, Overload, Surge protectionUnknown — not stated by the source
Audible alarm(s)Known for oneYesUnknown — not stated by the source
EfficiencyKnown for oneUnknown — not stated by the source95%
Efficiency (ECO mode)Known for oneUnknown — not stated by the source99%
Output power factorKnown for oneUnknown — not stated by the source1
ECO modeKnown for oneUnknown — not stated by the sourceYes
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
Ports & interfacesidentical
AC outlet typesKnown for oneC13 couplerUnknown — not stated by the source
Power plugKnown for oneC14 couplerUnknown — not stated by the source
AC outlets quantityKnown for one10 AC outlet(s)Unknown — not stated by the source
USB portKnown for oneYesUnknown — not stated by the source
Serial interfaceKnown for oneYesUnknown — not stated by the source
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
Batteryidentical
Battery technologyKnown for oneLead-AcidUnknown — not stated by the source
Typical backup time at full loadKnown for one4 minUnknown — not stated by the source
Typical backup time at half loadKnown for one12 minUnknown — not stated by the source
Battery recharge timeKnown for one3 hUnknown — not stated by the source
Replacement battery cartridgeKnown for oneRBP0129Unknown — not stated by the source
Design1 differ
Form factorKnown for oneRackmount/TowerUnknown — not stated by the source
Product colourDiffersBlackWhite, Black
Housing materialKnown for oneMetalUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsKnown for onePower, FaultUnknown — not stated by the source
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP20
Operational conditions1 differ
Storage temperature (T-T)Differs-15 - 45 °C-20 - 50 °C
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneCE, Federal Communications Commission (FCC), cUL, UL, VCCI, RoHSUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers433 mm560 mm
DepthDiffers500 mm940 mm
HeightDiffers86.5 mm1500 mm
WeightDiffers3.44 kg250 kg
Packaging dataidentical
Package widthKnown for one560 mmUnknown — not stated by the source
Package depthKnown for one620 mmUnknown — not stated by the source
Package heightKnown for one275 mmUnknown — not stated by the source
Package weightKnown for one4.13 kgUnknown — not stated by the source
Packaging contentidentical
ManualKnown for oneUnknown — not stated by the sourceYes

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons