Product comparison · 2 uninterruptible power supplies (upss)

CyberPower PR1000RT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA vs CyberPower PR750RT2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA

Add a product
  • 51specifications compared
  • 11differ
  • 40identical
  • 13known for one product only

Key differences

  • Output power capacity
    • PR1000RT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:1 kVA
    • PR750RT2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:0.75 kVA
  • Output power
    • PR1000RT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:1000 W
    • PR750RT2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:750 W
  • Input operation voltage (min)
    • PR1000RT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:70 V
    • PR750RT2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:100 V
  • Input operation voltage (max)
    • PR1000RT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:155 V
    • PR750RT2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:125 V
  • AC outlet types
    • PR1000RT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:NEMA 5–15R
    • PR750RT2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:NEMA 5-15R
  • Battery capacity
    • PR1000RT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:7 Ah
    • PR750RT2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:5 Ah
  • Typical backup time at full load
    • PR1000RT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:7 min
    • PR750RT2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:7.5 min
  • Typical backup time at half load
    • PR1000RT2U uninterruptible power supply (UPS) Line-Interactive 1 kVA:19.5 min
    • PR750RT2U uninterruptible power supply (UPS) Line-Interactive 0.75 kVA:19 min

Side by side

Differences highlightedShow differences only (on)
Comparison of PR1000RT2U, PR750RT2U
64 specifications
Features5 differ
Output power capacityDiffers1 kVA0.75 kVA
Output powerDiffers1000 W750 W
Input operation voltage (min)Differs70 V100 V
Input operation voltage (max)Differs155 V125 V
Response timeKnown for oneUnknown — not stated by the source4 ms
Audible alarm modesDiffersAlarm when on battery, Low battery alarmAlarm when on battery, Low battery alarm, Overload alarm
Transfer time (Line Mode to Battery Mode)Known for one4 msUnknown — not stated by the source
Ports & interfaces1 differ
AC outlet typesDiffersNEMA 5–15RNEMA 5-15R
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
USB portKnown for oneYesUnknown — not stated by the source
RS-232 portsKnown for one1Unknown — not stated by the source
Battery3 differ
Battery capacityDiffers7 Ah5 Ah
Typical backup time at full loadDiffers7 min7.5 min
Typical backup time at half loadDiffers19.5 min19 min
Battery recharge timeKnown for oneUnknown — not stated by the source3 h
Battery recharge time(90%)Known for one3 hUnknown — not stated by the source
Operational conditionsidentical
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Weight & dimensions1 differ
WeightDiffers20.7 kg18 kg
Packaging dataidentical
Screws includedKnown for oneUnknown — not stated by the sourceYes
Package widthKnown for oneUnknown — not stated by the source561.3 mm
Package depthKnown for oneUnknown — not stated by the source530.9 mm
Package heightKnown for oneUnknown — not stated by the source274.3 mm
Package weightKnown for oneUnknown — not stated by the source23.2 kg
Other features1 differ
Battery typeDiffersRB1270X4HRB1250X4

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.