Product comparison · 2 uninterruptible power supplies (upss)

CyberPower PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA vs Salicru SLC-2000-TWIN PRO2 IEC

Add a product
  • 30specifications compared
  • 22differ
  • 8identical
  • 54known for one product only

Key differences

The Salicru SLC-2000-TWIN PRO2 IEC has 1 kVA more output power capacity than the CyberPower PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA (2 kVA vs 1 kVA). The Salicru SLC-2000-TWIN PRO2 IEC has 900 W more output power than the CyberPower PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA (1800 W vs 900 W). The Salicru SLC-2000-TWIN PRO2 IEC has 140 V more input operation voltage (min) than the CyberPower PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA (220 V vs 80 V). UPS topology: Line-Interactive on the CyberPower PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA, Double-conversion (Online) on the Salicru SLC-2000-TWIN PRO2 IEC. Waveform: Sine on the CyberPower PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA, Pure sine on the Salicru SLC-2000-TWIN PRO2 IEC.

  • UPS topology
    • PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA:Line-Interactive
    • SLC-2000-TWIN PRO2 IEC:Double-conversion (Online)
  • Output power capacity
    • PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA:1 kVA
    • SLC-2000-TWIN PRO2 IEC:2 kVA
  • Output power
    • PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA:900 W
    • SLC-2000-TWIN PRO2 IEC:1800 W
  • Waveform
    • PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA:Sine
    • SLC-2000-TWIN PRO2 IEC:Pure sine
  • Input operation voltage (min)
    • PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA:80 V
    • SLC-2000-TWIN PRO2 IEC:220 V
  • Input operation voltage (max)
    • PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA:150 V
    • SLC-2000-TWIN PRO2 IEC:240 V
  • Input frequency
    • PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA:47/63 Hz
    • SLC-2000-TWIN PRO2 IEC:50/60 Hz
  • AC outlet types
    • PR1000LCDRTXL2UTAA uninterruptible power supply (UPS) Line-Interactive 1 kVA:NEMA 5-15R
    • SLC-2000-TWIN PRO2 IEC:C13 coupler, IEC Jumpers

Side by side

Differences highlightedShow differences only (on)
Comparison of PR1000LCDRTXL2UTAA, 699CA000017
84 specifications
B

Salicru

SLC-2000-TWIN PRO2 IEC

Model 699CA000017

View product
Features9 differ
UPS topologyDiffersLine-InteractiveDouble-conversion (Online)
Output power capacityDiffers1 kVA2 kVA
Output powerDiffers900 W1800 W
WaveformDiffersSinePure sine
Input operation voltage (min)Differs80 V220 V
Input operation voltage (max)Differs150 V240 V
Input frequencyDiffers47/63 Hz50/60 Hz
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one2060 JUnknown — not stated by the source
Response timeKnown for one4 msUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protection featuresKnown for oneCoax, Network, TelephoneUnknown — not stated by the source
Power protection featuresDiffersShort circuitOver current, Short circuit, Under current, Under voltage
Web-based managementKnown for oneYesUnknown — not stated by the source
Audible alarm modesDiffersAlarm when on battery, Low battery alarm, Overload alarmAlarm when on battery, Fault, Low battery alarm, Overload alarm, Battery replacement
Output operation voltage (min)Known for oneUnknown — not stated by the source220 V
Output operation voltage (max)Known for oneUnknown — not stated by the source240 V
Output frequency regulationKnown for oneUnknown — not stated by the source0.05 Hz
Output voltage regulationKnown for oneUnknown — not stated by the source1%
Number of input phasesKnown for oneUnknown — not stated by the source1
Number of output phasesKnown for oneUnknown — not stated by the source1
Efficiency (On-line mode)Known for oneUnknown — not stated by the source92%
Efficiency (ECO mode)Known for oneUnknown — not stated by the source98%
Input power factorKnown for oneUnknown — not stated by the source0.99
Output power factorKnown for oneUnknown — not stated by the source0.9
ECO modeKnown for oneUnknown — not stated by the sourceYes
Overload capacity (1 minute)Known for oneUnknown — not stated by the source130%
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source2%
Input current Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source2%
Noise levelKnown for oneUnknown — not stated by the source49 dB
Ports & interfaces3 differ
AC outlet typesDiffersNEMA 5-15RC13 coupler, IEC Jumpers
Power plugDiffersNEMA 5-15PC19 coupler
AC outlets quantityDiffers8 AC outlet(s)4 AC outlet(s)
Serial interfaceKnown for oneYesUnknown — not stated by the source
Serial ports quantityKnown for one2Unknown — not stated by the source
Modem (RJ-11) portsKnown for one1Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Number of output IEC jumpersKnown for oneUnknown — not stated by the source4
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Emergency Power Off (EPO) connectorKnown for oneUnknown — not stated by the sourceYes
Battery2 differ
Battery technologyDiffersSealed Lead Acid (VRLA)Lead-Calcium (Pb-Ca)
Battery capacityKnown for one7 AhUnknown — not stated by the source
Battery voltageKnown for one12 VUnknown — not stated by the source
Number of batteries supportedKnown for one4Unknown — not stated by the source
Typical backup time at full loadKnown for one9 minUnknown — not stated by the source
Typical backup time at half loadKnown for one22 minUnknown — not stated by the source
Battery recharge timeDiffers6 h4 h
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Replacement battery cartridgeKnown for oneRB1270X4FUnknown — not stated by the source
Automatic battery testKnown for oneUnknown — not stated by the sourceYes
Off-mode chargingKnown for oneUnknown — not stated by the sourceYes
Design2 differ
Form factorDiffersRackmount/TowerTower
Rack capacityKnown for one2UUnknown — not stated by the source
Cable lengthKnown for one3.04 mUnknown — not stated by the source
LED indicatorsDiffersFault, PowerBattery replacement
Cooling typeKnown for oneUnknown — not stated by the sourceActive
Built-in fanKnown for oneUnknown — not stated by the sourceYes
Operational conditions1 differ
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating altitudeDiffers0 - 3000 m0 - 5000 m
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Packaging contentidentical
Rack mount kitKnown for oneYesUnknown — not stated by the source
Cables includedKnown for oneSerial, USB cableUnknown — not stated by the source
ManualKnown for oneYesUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Safety regulation & standards1 differ
SafetyDiffersUL1778, cUL 107.1, FCC DOC Class BEN 62040-1:2008+A1:2013
Weight & dimensions4 differ
WidthDiffers438 mm190 mm
DepthDiffers400 mm399 mm
HeightDiffers89 mm327 mm
WeightDiffers24.5 kg18.4 kg
Packaging dataidentical
BracketKnown for oneYesUnknown — not stated by the source
Rubber feetKnown for oneYesUnknown — not stated by the source
Software CDKnown for oneYesUnknown — not stated by the source
Warranty cardKnown for oneYesUnknown — not stated by the source
Logistics dataidentical
Harmonized System (HS) codeKnown for oneUnknown — not stated by the source85078000
Other featuresidentical
Battery typeKnown for oneUnknown — not stated by the sourceAGM

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.