Product comparison · 2 uninterruptible power supplies (upss)

CyberPower PR1000LCDRTXL2U uninterruptible power supply (UPS) 1 kVA vs CyberPower PR1500LCDRT2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA

Add a product
  • 18specifications compared
  • 6differ
  • 12identical
  • 25known for one product only

Key differences

The CyberPower PR1500LCDRT2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA has 0.5 kVA more output power capacity than the CyberPower PR1000LCDRTXL2U uninterruptible power supply (UPS) 1 kVA (1.5 kVA vs 1 kVA). The CyberPower PR1000LCDRTXL2U uninterruptible power supply (UPS) 1 kVA has 5 min more typical backup time at full load than the CyberPower PR1500LCDRT2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (11 min vs 6 min). The CyberPower PR1000LCDRTXL2U uninterruptible power supply (UPS) 1 kVA has 14 min more typical backup time at half load than the CyberPower PR1500LCDRT2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (32 min vs 18 min). Operating temperature (T-T): 0 - 35 °C on the CyberPower PR1000LCDRTXL2U uninterruptible power supply (UPS) 1 kVA, 0 - 40 °C on the CyberPower PR1500LCDRT2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA. Output connections: 6 x NEMA 5-15R on the CyberPower PR1000LCDRTXL2U uninterruptible power supply (UPS) 1 kVA, NEMA 5-15R on the CyberPower PR1500LCDRT2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA.

  • Output power capacity
    • PR1000LCDRTXL2U uninterruptible power supply (UPS) 1 kVA:1 kVA
    • PR1500LCDRT2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
  • Typical backup time at full load
    • PR1000LCDRTXL2U uninterruptible power supply (UPS) 1 kVA:11 min
    • PR1500LCDRT2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:6 min
  • Typical backup time at half load
    • PR1000LCDRTXL2U uninterruptible power supply (UPS) 1 kVA:32 min
    • PR1500LCDRT2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:18 min
  • Operating temperature (T-T)
    • PR1000LCDRTXL2U uninterruptible power supply (UPS) 1 kVA:0 - 35 °C
    • PR1500LCDRT2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:0 - 40 °C
  • Weight
    • PR1000LCDRTXL2U uninterruptible power supply (UPS) 1 kVA:28.6 kg
    • PR1500LCDRT2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:25.4 kg
  • Output connections
    • PR1000LCDRTXL2U uninterruptible power supply (UPS) 1 kVA:6 x NEMA 5-15R
    • PR1500LCDRT2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:NEMA 5-15R

Side by side

Differences highlightedShow differences only (on)
Comparison of PR1000LCDRTXL2U, PR1500LCDRT2U
43 specifications
Features1 differ
Output power capacityDiffers1 kVA1.5 kVA
Surge protectionKnown for oneYesUnknown — not stated by the source
UPS topologyKnown for oneUnknown — not stated by the sourceLine-Interactive
Output powerKnown for oneUnknown — not stated by the source1000 W
Input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Response timeKnown for oneUnknown — not stated by the source4 ms
Ports & interfacesidentical
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
Battery2 differ
Typical backup time at full loadDiffers11 min6 min
Typical backup time at half loadDiffers32 min18 min
Replacement battery cartridgeKnown for oneUnknown — not stated by the sourceBB - BP7-12
Designidentical
Product colourKnown for oneBlackUnknown — not stated by the source
Rack capacityKnown for one2UUnknown — not stated by the source
Cable lengthKnown for one3 mUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 35 °C0 - 40 °C
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Weight & dimensions1 differ
WidthKnown for one438.1 mmUnknown — not stated by the source
DepthKnown for one400.1 mmUnknown — not stated by the source
HeightKnown for one88.9 mmUnknown — not stated by the source
WeightDiffers28.6 kg25.4 kg
Packaging dataidentical
Bundled softwareKnown for onePowerPanel Business EdUnknown — not stated by the source
Other features1 differ
Battery typeKnown for oneBB 12V/7.0AHUnknown — not stated by the source
Output connectionsDiffers6 x NEMA 5-15RNEMA 5-15R
Compatible operating systemsKnown for oneWindows 200x, Server, XP, Vista, Windows 7Unknown — not stated by the source
Management platformKnown for oneSNMP, HTTPUnknown — not stated by the source
Nominal output voltageKnown for one120 VUnknown — not stated by the source
Dimensions (WxDxH)Known for oneUnknown — not stated by the source438.15 x 400 x 89 mm
Operating temperature (T-T)Known for oneUnknown — not stated by the source32 - 95 °F
Dimensions (W x D x H) (imperial)Known for oneUnknown — not stated by the source438.1 x 400.1 x 88.9 mm (17.2 x 15.8 x 3.5")
Weight (imperial)Known for oneUnknown — not stated by the source25.4 kg (56 lbs)

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons

All uninterruptible power supplies (upss) comparisons