Product comparison · 2 uninterruptible power supplies (upss)

CyberPower PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA vs Salicru SPS 2000 ONE A

Add a product
  • 28specifications compared
  • 23differ
  • 5identical
  • 35known for one product only

Key differences

  • UPS topology
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:Double-conversion (Online)
    • SPS 2000 ONE A:Line-Interactive
  • Output power capacity
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:10 kVA
    • SPS 2000 ONE A:2 kVA
  • Output power
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:9000 W
    • SPS 2000 ONE A:1200 W
  • Input operation voltage (min)
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:120 V
    • SPS 2000 ONE A:81 V
  • Input operation voltage (max)
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:280 V
    • SPS 2000 ONE A:145 V
  • Input frequency
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:40 - 70 Hz
    • SPS 2000 ONE A:50/60 Hz
  • Output operation voltage (min)
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:120 V
    • SPS 2000 ONE A:110 V
  • Output operation voltage (max)
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:240 V
    • SPS 2000 ONE A:120 V

Side by side

Differences highlightedShow differences only (off)
Comparison of PDU32MHVCEE18AT, SPS 2000 ONE A
63 specifications
Features11 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers10 kVA2 kVA
Output powerDiffers9000 W1200 W
WaveformSineSine
Input operation voltage (min)Differs120 V81 V
Input operation voltage (max)Differs280 V145 V
Input frequencyDiffers40 - 70 Hz50/60 Hz
Output operation voltage (min)Differs120 V110 V
Output operation voltage (max)Differs240 V120 V
Surge energy ratingKnown for one2670 JUnknown — not stated by the source
Power factorKnown for one0.9Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Noise levelDiffers55 dB40 dB
Surge protection featuresDiffersNetwork, TelephoneFax, Modem
Power protection featuresKnown for oneOverload, Short circuitUnknown — not stated by the source
Audible alarm(s)YesYes
Audible alarm modesDiffersAlarm when on battery, Battery replacementBattery replacement, Overload alarm
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Response timeKnown for oneUnknown — not stated by the source6 ms
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Auto-restartKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces1 differ
AC outlet typesKnown for oneNEMA 5–20R, NEMA L6-20R, NEMA L6-30R, TerminalUnknown — not stated by the source
AC outlets quantityDiffers13 AC outlet(s)8 AC outlet(s)
USB portYesYes
Serial interfaceKnown for oneYesUnknown — not stated by the source
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
Modem (RJ-11) portsKnown for one2Unknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
USB 2.0 ports quantityKnown for oneUnknown — not stated by the source1
Battery2 differ
Battery technologyDiffersSealed Lead Acid (VRLA)Lead-Calcium (Pb-Ca)
Battery capacityKnown for one9 AhUnknown — not stated by the source
Number of batteries supportedKnown for one20Unknown — not stated by the source
Typical backup time at full loadKnown for one4 minUnknown — not stated by the source
Typical backup time at half loadKnown for one11 minUnknown — not stated by the source
Battery recharge timeDiffers5 h6 h
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Replacement battery cartridgeKnown for oneRB1290X20Unknown — not stated by the source
Cold startKnown for oneUnknown — not stated by the sourceYes
Design3 differ
Form factorDiffersRackmount/TowerTower
Product colourDiffersBlackRed
Housing materialKnown for oneSteelUnknown — not stated by the source
Rack capacityKnown for one8UUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsDiffersPowerYes
Operational conditions1 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)0 - 90%0 - 90%
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeDiffers0 - 3000 m0 - 2400 m
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Packaging contentidentical
Cables includedKnown for oneSerial, USB cableUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Safety regulation & standards1 differ
SafetyDiffersUL1778, CSA C22.2 NO.107.3-05, FCC DOC Class AEN-IEC 62040-1
Weight & dimensions4 differ
WidthDiffers433 mm146 mm
DepthDiffers820 mm397 mm
HeightDiffers352 mm205 mm
WeightDiffers160.8 kg11.5 kg
Packaging dataidentical
Package widthKnown for one620 mmUnknown — not stated by the source
Package depthKnown for one1120 mmUnknown — not stated by the source
Package heightKnown for one1028 mmUnknown — not stated by the source
Package weightKnown for one207.5 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.