Product comparison · 2 uninterruptible power supplies (upss)

CyberPower PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA vs CyberPower UT650EG uninterruptible power supply (UPS) Line-Interactive 0.65 kVA

Add a product
  • 31specifications compared
  • 22differ
  • 9identical
  • 30known for one product only

Key differences

  • UPS topology
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:Double-conversion (Online)
    • UT650EG uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:Line-Interactive
  • Output power capacity
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:10 kVA
    • UT650EG uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:0.65 kVA
  • Output power
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:9000 W
    • UT650EG uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:360 W
  • Input operation voltage (min)
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:120 V
    • UT650EG uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:165 V
  • Input operation voltage (max)
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:280 V
    • UT650EG uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:290 V
  • Input frequency
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:40 - 70 Hz
    • UT650EG uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:50/60 Hz
  • Output operation voltage (max)
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:240 V
    • UT650EG uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:230 V
  • Power protection features
    • PDU32MHVCEE18AT uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA:Overload, Short circuit
    • UT650EG uninterruptible power supply (UPS) Line-Interactive 0.65 kVA:Overload

Side by side

Differences highlightedShow differences only (off)
Comparison of PDU32MHVCEE18AT, UT650EG
61 specifications
Features9 differ
UPS topologyDiffersDouble-conversion (Online)Line-Interactive
Output power capacityDiffers10 kVA0.65 kVA
Output powerDiffers9000 W360 W
WaveformSineSine
Input operation voltage (min)Differs120 V165 V
Input operation voltage (max)Differs280 V290 V
Input frequencyDiffers40 - 70 Hz50/60 Hz
Output operation voltage (min)Known for one120 VUnknown — not stated by the source
Output operation voltage (max)Differs240 V230 V
Surge energy ratingKnown for one2670 JUnknown — not stated by the source
Power factorKnown for one0.9Unknown — not stated by the source
Output voltage Total Harmonic Distortion (THD)Known for one5%Unknown — not stated by the source
EMI/RFI noise filteringYesYes
Noise levelKnown for one55 dBUnknown — not stated by the source
Surge protection featuresKnown for oneNetwork, TelephoneUnknown — not stated by the source
Power protection featuresDiffersOverload, Short circuitOverload
Audible alarm(s)YesYes
Audible alarm modesDiffersAlarm when on battery, Battery replacementAlarm when on battery, Fault, Low battery alarm, Overload alarm
Automatic Voltage Regulation (AVR)Known for oneUnknown — not stated by the sourceYes
Response timeKnown for oneUnknown — not stated by the source4 ms
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5–20R, NEMA L6-20R, NEMA L6-30R, TerminalType F
AC outlets quantityDiffers13 AC outlet(s)3 AC outlet(s)
USB portKnown for oneYesUnknown — not stated by the source
Serial interfaceKnown for oneYesUnknown — not stated by the source
Serial interface typeKnown for oneRS-232Unknown — not stated by the source
Modem (RJ-11) portsKnown for one2Unknown — not stated by the source
Emergency Power Off (EPO) connectorKnown for oneYesUnknown — not stated by the source
Battery1 differ
Battery technologySealed Lead Acid (VRLA)Sealed Lead Acid (VRLA)
Battery capacityKnown for one9 AhUnknown — not stated by the source
Number of batteries supportedKnown for one20Unknown — not stated by the source
Typical backup time at full loadKnown for one4 minUnknown — not stated by the source
Typical backup time at half loadKnown for one11 minUnknown — not stated by the source
Battery recharge timeDiffers5 h6 h
Hot-swap batteryKnown for oneYesUnknown — not stated by the source
Replacement battery cartridgeKnown for oneRB1290X20Unknown — not stated by the source
Design3 differ
Form factorDiffersRackmount/TowerTower
Product colourBlackBlack
Housing materialDiffersSteelPlastic
Rack capacityKnown for one8UUnknown — not stated by the source
Display typeKnown for oneLCDUnknown — not stated by the source
LED indicatorsDiffersPowerYes
Cable lengthKnown for oneUnknown — not stated by the source1.2 m
Operational conditions3 differ
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Differs-15 - 45 °C-20 - 50 °C
Operating relative humidity (H-H)0 - 90%0 - 90%
Storage relative humidity (H-H)Differs0 - 95%0 - 90%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitudeDiffers0 - 15000 m0 - 3000 m
Packaging contentidentical
Cables includedKnown for oneSerial, USB cableUnknown — not stated by the source
Certificatesidentical
Compliance certificatesRoHSRoHS
CertificationKnown for oneUnknown — not stated by the sourceCE
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUL1778, CSA C22.2 NO.107.3-05, FCC DOC Class AUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers433 mm84 mm
DepthDiffers820 mm280 mm
HeightDiffers352 mm174 mm
WeightDiffers160.8 kg3.8 kg
Packaging dataidentical
Package widthKnown for one620 mmUnknown — not stated by the source
Package depthKnown for one1120 mmUnknown — not stated by the source
Package heightKnown for one1028 mmUnknown — not stated by the source
Package weightKnown for one207.5 kgUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.