The CyberPower OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA has 0.5 kVA more output power capacity than the CyberPower PR1500LCDRTXL2UA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (2 kVA vs 1.5 kVA). The CyberPower PR1500LCDRTXL2UA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA has 30 W more output power than the CyberPower OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA (1350 W vs 1320 W). The CyberPower PR1500LCDRTXL2UA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA has 10 V more input operation voltage (max) than the CyberPower OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA (150 V vs 140 V). Input frequency: 50/60 Hz on the CyberPower OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA, 47/63 Hz on the CyberPower PR1500LCDRTXL2UA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA. AC outlet types: NEMA 5–20R on the CyberPower OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA, NEMA 5–15R on the CyberPower PR1500LCDRTXL2UA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA.

  • Output power capacity
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:2 kVA
    • PR1500LCDRTXL2UA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
  • Output power
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:1320 W
    • PR1500LCDRTXL2UA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1350 W
  • Input operation voltage (max)
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:140 V
    • PR1500LCDRTXL2UA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:150 V
  • Input frequency
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:50/60 Hz
    • PR1500LCDRTXL2UA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:47/63 Hz
  • Surge energy rating
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:1840 J
    • PR1500LCDRTXL2UA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:2060 J
  • AC outlet types
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:NEMA 5–20R
    • PR1500LCDRTXL2UA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:NEMA 5–15R
  • Power plug
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:NEMA 5-20P
    • PR1500LCDRTXL2UA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:NEMA 5-15P
  • Serial ports quantity
    • OR2200LCDRT2U uninterruptible power supply (UPS) Line-Interactive 2 kVA:2
    • PR1500LCDRTXL2UA uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1

Side by side

Differences highlightedShow differences only (on)
Comparison of OR2200LCDRT2U, PR1500LCDRTXL2UA
60 specifications
Features5 differ
Output power capacityDiffers2 kVA1.5 kVA
Output powerDiffers1320 W1350 W
WaveformKnown for oneUnknown — not stated by the sourceSine
Input operation voltage (max)Differs140 V150 V
Input frequencyDiffers50/60 Hz47/63 Hz
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Surge energy ratingDiffers1840 J2060 J
Power factorKnown for oneUnknown — not stated by the source0.9
Emergency Power Off (EPO)Known for oneUnknown — not stated by the sourceYes
EMI/RFI noise filteringKnown for oneUnknown — not stated by the sourceYes
Power protection featuresKnown for oneUnknown — not stated by the sourceOverload
Input operation voltage (min)Known for one90 VUnknown — not stated by the source
Output operation voltage (min)Known for one120 VUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Response timeKnown for one10 msUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Surge protection featuresKnown for oneCoax, Network, TelephoneUnknown — not stated by the source
Ports & interfaces3 differ
AC outlet typesDiffersNEMA 5–20RNEMA 5–15R
Power plugDiffersNEMA 5-20PNEMA 5-15P
Serial ports quantityDiffers21
Modem (RJ-11) portsKnown for one2Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for one1Unknown — not stated by the source
Battery2 differ
Typical backup time at full loadDiffers5 min4 min
Battery recharge timeDiffers8 h6 h
Battery capacityKnown for one9 AhUnknown — not stated by the source
Battery voltageKnown for one12 VUnknown — not stated by the source
Design1 differ
Cable lengthDiffers6 m3 m
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cooling typeKnown for oneActiveUnknown — not stated by the source
Operational conditionsidentical
Storage temperature (T-T)Known for oneUnknown — not stated by the source-15 - 45 °C
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source0 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15000 m
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Safety regulation & standards1 differ
SafetyDiffersUL1778, cUL, CSAC22.2, 107.1, FCC DOC Class BUL1778, CSA C22.2 NO.107.3-05, FCC DOC Class A
Weight & dimensions2 differ
WidthDiffers438.1 mm431.8 mm
WeightDiffers23.9 kg25.9 kg
Packaging dataidentical
Package widthKnown for oneUnknown — not stated by the source558.8 mm
Package depthKnown for oneUnknown — not stated by the source520.7 mm
Package heightKnown for oneUnknown — not stated by the source248.9 mm
Package weightKnown for oneUnknown — not stated by the source29.5 kg
Other featuresidentical
Output voltageKnown for oneUnknown — not stated by the source120 V
Battery typeKnown for oneRB1290X4GUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.