Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA vs Legrand Niky S 2000VA 1200W

Add a product
  • 19specifications compared
  • 15differ
  • 4identical
  • 24known for one product only

Key differences

The Legrand Niky S 2000VA 1200W has 0.5 kVA more output power capacity than the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (2 kVA vs 1.5 kVA). The Legrand Niky S 2000VA 1200W has 150 W more output power than the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (1200 W vs 1050 W). The Legrand Niky S 2000VA 1200W has 82 V more input operation voltage (min) than the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (160 V vs 78 V). AC outlet types: NEMA 5–15R on the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, C13 coupler on the Legrand Niky S 2000VA 1200W. AC outlets quantity: 8 AC outlet(s) on the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, 6 AC outlet(s) on the Legrand Niky S 2000VA 1200W.

  • Output power capacity
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
    • Niky S 2000VA 1200W:2 kVA
  • Output power
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1050 W
    • Niky S 2000VA 1200W:1200 W
  • Input operation voltage (min)
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:78 V
    • Niky S 2000VA 1200W:160 V
  • Input operation voltage (max)
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:142 V
    • Niky S 2000VA 1200W:290 V
  • Output operation voltage (min)
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:120 V
    • Niky S 2000VA 1200W:207 V
  • Output operation voltage (max)
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:120 V
    • Niky S 2000VA 1200W:253 V
  • AC outlet types
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:NEMA 5–15R
    • Niky S 2000VA 1200W:C13 coupler
  • AC outlets quantity
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:8 AC outlet(s)
    • Niky S 2000VA 1200W:6 AC outlet(s)

Side by side

Differences highlightedShow differences only (on)
Comparison of OR1500PFCLCD, Niky S 2000VA 1200W
43 specifications
Features6 differ
Output power capacityDiffers1.5 kVA2 kVA
Output powerDiffers1050 W1200 W
Input operation voltage (min)Differs78 V160 V
Input operation voltage (max)Differs142 V290 V
Output operation voltage (min)Differs120 V207 V
Output operation voltage (max)Differs120 V253 V
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one1030 JUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Noise levelKnown for oneUnknown — not stated by the source40 dB
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5–15RC13 coupler
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
AC outlets quantityDiffers8 AC outlet(s)6 AC outlet(s)
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
RS-232 portsKnown for oneUnknown — not stated by the source1
Battery2 differ
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Number of batteries supportedDiffers24
Typical backup time at full loadDiffers4 min9 min
Typical backup time at half loadKnown for one12 minUnknown — not stated by the source
Battery recharge timeKnown for one8 hUnknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source7 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Designidentical
Form factorKnown for oneMini TowerUnknown — not stated by the source
Cable lengthKnown for one1.8 mUnknown — not stated by the source
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Operational conditions1 differ
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Differs0 - 90%0 - 95%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceEN 62040-1, EN 62040-2, EN 62040-3
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUL1778 4th, cUL 107.3-05, FCC/DoC Class BUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers137 mm173 mm
DepthDiffers163 mm465 mm
HeightDiffers351 mm247 mm
WeightDiffers11.3 kg22 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More uninterruptible power supplies (upss) comparisons