Product comparison · 2 uninterruptible power supplies (upss)

CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA vs Legrand Niky S 1500VA 900W

Add a product
  • 19specifications compared
  • 13differ
  • 6identical
  • 24known for one product only

Key differences

The CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA has 150 W more output power than the Legrand Niky S 1500VA 900W (1050 W vs 900 W). The Legrand Niky S 1500VA 900W has 82 V more input operation voltage (min) than the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (160 V vs 78 V). The Legrand Niky S 1500VA 900W has 148 V more input operation voltage (max) than the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (290 V vs 142 V). AC outlet types: NEMA 5–15R on the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, C13 coupler on the Legrand Niky S 1500VA 900W. AC outlets quantity: 8 AC outlet(s) on the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, 6 AC outlet(s) on the Legrand Niky S 1500VA 900W.

  • Output power
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1050 W
    • Niky S 1500VA 900W:900 W
  • Input operation voltage (min)
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:78 V
    • Niky S 1500VA 900W:160 V
  • Input operation voltage (max)
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:142 V
    • Niky S 1500VA 900W:290 V
  • Output operation voltage (min)
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:120 V
    • Niky S 1500VA 900W:207 V
  • Output operation voltage (max)
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:120 V
    • Niky S 1500VA 900W:253 V
  • AC outlet types
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:NEMA 5–15R
    • Niky S 1500VA 900W:C13 coupler
  • AC outlets quantity
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:8 AC outlet(s)
    • Niky S 1500VA 900W:6 AC outlet(s)
  • Typical backup time at full load
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:4 min
    • Niky S 1500VA 900W:8 min

Side by side

Differences highlightedShow differences only (on)
Comparison of OR1500PFCLCD, Niky S 1500VA 900W
43 specifications
Features5 differ
Output powerDiffers1050 W900 W
Input operation voltage (min)Differs78 V160 V
Input operation voltage (max)Differs142 V290 V
Output operation voltage (min)Differs120 V207 V
Output operation voltage (max)Differs120 V253 V
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one1030 JUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Noise levelKnown for oneUnknown — not stated by the source40 dB
Ports & interfaces2 differ
AC outlet typesDiffersNEMA 5–15RC13 coupler
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
AC outlets quantityDiffers8 AC outlet(s)6 AC outlet(s)
USB 2.0 ports quantityKnown for one1Unknown — not stated by the source
RS-232 portsKnown for oneUnknown — not stated by the source1
Battery1 differ
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Typical backup time at full loadDiffers4 min8 min
Typical backup time at half loadKnown for one12 minUnknown — not stated by the source
Battery recharge timeKnown for one8 hUnknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source9 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Designidentical
Form factorKnown for oneMini TowerUnknown — not stated by the source
Cable lengthKnown for one1.8 mUnknown — not stated by the source
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Operational conditions1 differ
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Differs0 - 90%0 - 95%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceEN 62040-1, EN 62040-2, EN 62040-3
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUL1778 4th, cUL 107.3-05, FCC/DoC Class BUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers137 mm173 mm
DepthDiffers163 mm369 mm
HeightDiffers351 mm247 mm
WeightDiffers11.3 kg15 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.