Key differences

The Legrand Keor Line RT has 0.7 kVA more output power capacity than the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (2.2 kVA vs 1.5 kVA). The Legrand Keor Line RT has 930 W more output power than the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (1980 W vs 1050 W). The Legrand Keor Line RT has 87 V more input operation voltage (min) than the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA (165 V vs 78 V). Input frequency: 50/60 Hz on the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, 45/65 Hz on the Legrand Keor Line RT. AC outlets quantity: 8 AC outlet(s) on the CyberPower OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA, 9 AC outlet(s) on the Legrand Keor Line RT.

  • Output power capacity
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1.5 kVA
    • Keor Line RT:2.2 kVA
  • Output power
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:1050 W
    • Keor Line RT:1980 W
  • Input operation voltage (min)
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:78 V
    • Keor Line RT:165 V
  • Input operation voltage (max)
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:142 V
    • Keor Line RT:300 V
  • Input frequency
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:50/60 Hz
    • Keor Line RT:45/65 Hz
  • AC outlets quantity
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:8 AC outlet(s)
    • Keor Line RT:9 AC outlet(s)
  • Number of batteries supported
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:2
    • Keor Line RT:6
  • Form factor
    • OR1500PFCLCD uninterruptible power supply (UPS) Line-Interactive 1.5 kVA:Mini Tower
    • Keor Line RT:Rackmount/Tower

Side by side

Differences highlightedShow differences only (off)
Comparison of OR1500PFCLCD, Keor Line RT
50 specifications
Features5 differ
UPS topologyLine-InteractiveLine-Interactive
Output power capacityDiffers1.5 kVA2.2 kVA
Output powerDiffers1050 W1980 W
Input operation voltage (min)Differs78 V165 V
Input operation voltage (max)Differs142 V300 V
Input frequencyDiffers50/60 Hz45/65 Hz
Output operation voltage (min)Known for one120 VUnknown — not stated by the source
Output operation voltage (max)Known for one120 VUnknown — not stated by the source
Automatic Voltage Regulation (AVR)Known for oneYesUnknown — not stated by the source
Surge energy ratingKnown for one1030 JUnknown — not stated by the source
EMI/RFI noise filteringKnown for oneYesUnknown — not stated by the source
Surge protectionKnown for oneYesUnknown — not stated by the source
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Output frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Output voltage Total Harmonic Distortion (THD)Known for oneUnknown — not stated by the source3%
Noise levelKnown for oneUnknown — not stated by the source40 dB
Ports & interfaces1 differ
AC outlet typesKnown for oneNEMA 5–15RUnknown — not stated by the source
Power plugKnown for oneNEMA 5-15PUnknown — not stated by the source
AC outlets quantityDiffers8 AC outlet(s)9 AC outlet(s)
USB 2.0 ports quantity11
RS-232 portsKnown for oneUnknown — not stated by the source1
Modem (RJ-11) portsKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Battery1 differ
Battery technologyKnown for oneSealed Lead Acid (VRLA)Unknown — not stated by the source
Number of batteries supportedDiffers26
Typical backup time at full loadKnown for one4 minUnknown — not stated by the source
Typical backup time at half loadKnown for one12 minUnknown — not stated by the source
Battery recharge timeKnown for one8 hUnknown — not stated by the source
Battery capacityKnown for oneUnknown — not stated by the source7 Ah
Battery voltageKnown for oneUnknown — not stated by the source12 V
Design1 differ
Form factorDiffersMini TowerRackmount/Tower
Product colourBlackBlack
Cable lengthKnown for one1.8 mUnknown — not stated by the source
Display typeKnown for oneUnknown — not stated by the sourceLCD
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Operational conditionsidentical
Operating temperature (T-T)0 - 40 °C0 - 40 °C
Storage temperature (T-T)Known for one-15 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 90%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15000 mUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceEN62040-1, EN62040-2, EN62040-3
Sustainabilityidentical
Sustainability certificatesKnown for oneENERGY STARUnknown — not stated by the source
Safety regulation & standardsidentical
SafetyKnown for oneUL1778 4th, cUL 107.3-05, FCC/DoC Class BUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers137 mm440 mm
DepthDiffers163 mm650 mm
HeightDiffers351 mm88 mm
WeightDiffers11.3 kg34 kg
Other featuresidentical
Number of phasesKnown for oneUnknown — not stated by the source1
Output voltageKnown for oneUnknown — not stated by the source230 V